Early cost estimating model for new bioabsorbable orthopedic implant candidates: A theoretical study
Source abstract
Abstract
An early health technology assessment (HTA) study was performed to assess the need for developing a new bioabsorbable implant for the treatment of specific orthopedic injuries. The Anterior Cruciate Ligament Reconstruction (ACLR) procedure was selected based on the need and potential impact of bioabsorbable implants in the treatment of ACL injuries. The economic model considers the possible health events after an ACLR (failures and other complications such as stiffness and pain). A decision tree approach was used, and several sensitivity analyses were performed using a Monte Carlo simulation. A cost estimating model was applied comparatively for currently available metal and bioabsorbable implants against a potential new bioabsorbable implant with improved performance. A reduction in stiffness and pain symptoms were considered as targets for these new implants performance, with reduced inflammation resulting from the use of materials with appropriate biological and mechanical properties. The current study estimates that, under the assumptions made, the introduction of a new bioabsorbable implant in ACLR surgeries may generate yearly cost savings. The model estimates positive cost-benefits of the new implant when it reduces the probability of failure by more than 30%, or reduces at least 14% the probability of complications of an inflammatory nature. The development of a new bioabsorbable orthopedic implant for ACLR is encouraged by this study identifying the need for new bioabsorbable implants with improved biological and mechanical performance. The results of this early HTA have made it possible to anticipate design needs and objectives for the research and development of new orthopedic bioabsorbable implants.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Knee injuries and reconstruction techniques · Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (52)
Show source-provided references
1. Short-term and long-term effects of orthopedic biodegradable implants10.1615/JLongTermEffMedImplants.v21.i2.10 ↗
2. Patient predictors of early revision surgery after anterior cruciate ligament reconstruction: a cohort study of 16,930 patients with 2-year follow-up
3. Cost-effectiveness of a biodegradable compared to a titanium fixation system in maxillofacial surgery: a multicenter randomized controlled trial
4. Anterior cruciate ligament reconstruction: contemporary revision options10.1053/j.otsm.2012.12.002 ↗
5. Bioabsorbable implants in orthopaedics: new developments and clinical applications10.5435/00124635-200109000-00001 ↗
6. Diagnosis of failed ACL reconstruction
7. Revision anterior cruciate ligament reconstruction: causes of failure, surgical technique, and clinical results
8. Bioabsorbable implants in orthopaedics10.4103/0019-5413.34496 ↗
9. Calcium phosphate bioceramics: a review of their history, structure, properties, coating technologies and biomedical applications10.3390/ma10040334 ↗
10. Ellman · 2011
11. Bioabsorbable versus metallic screw fixation for tibiofibular syndesmotic Ruptures : a meta-analysis10.1053/j.jfas.2015.03.014 ↗
12. Orthopedic implants: applications of bioabsorbable polymers
13. HTA of medical devices: challenges and ideas for the future from a European perspective
14. A cost-effectiveness analysis comparing 3 anterior cruciate ligament graft types. Bone-patellar tendon-bone autograft, hamstring autograft, and allograft10.1177/0363546511426088 ↗
15. Current concepts review: revision anterior cruciate ligament reconstruction10.1177/0363546506295026 ↗
16. A 2-year follow-up of rehabilitation after ACL reconstruction using patellar tendon or hamstring tendon grafts: a prospective randomised outcome study10.1007/s00167-009-0961-3 ↗
17. The rate of subsequent surgery and predictors following ACL reconstruction: two- and six-year follow-up from a multicenter cohort10.1177/0363546513490277 ↗
18. Early assessment of medical technologies to inform product development and market access. A review of methods and applications10.2165/11593380-000000000-00000 ↗
19. Comparison of revision surgery with primary anterior cruciate ligament reconstruction and outcome of revision surgery between different graft materials10.1177/0363546508317124 ↗
20. Epidemiology and diagnosis of anterior cruciate ligament injuries10.1016/j.csm.2016.08.001 ↗
21. Bioabsorbable materials in orthopaedics
22. Rehabilitation after anterior cruciate ligament reconstruction
23. Bioabsorbable versus metal interference screws: adverse events and clinical results
24. Biological strategies for improved osseointegration and osteoinduction of porous metal orthopedic implants10.1089/ten.teb.2014.0333 ↗
25. Anterior cruciate ligament reconstruction - evolution and current concepts10.1016/j.mporth.2014.12.002 ↗
26. Analysis of 16,192 anterior cruciate ligament reconstructions from a community-based registry10.1177/0363546513493589 ↗
27. Assessing the effectiveness of health interventions
28. Medical devices early assessment methods: systematic literature review10.1017/S0266462314000026 ↗
29. Descriptive epidemiology of the multicenter ACL revision study (MARS) cohort10.1177/0363546510378645 ↗
30. Bioabsorbable versus metallic interference screws in anterior cruciate ligament reconstruction: a systematic review of overlapping meta-analyses10.1016/j.arthro.2014.11.011 ↗
31. Cost-effectiveness analysis of early and delayed reconstruction for anterior cruciate ligament tears10.1177/0363546514530866 ↗
32. Loss of extension following anterior cruciate ligament IKDC criteria10.1016/j.arthro.2007.08.026 ↗
33. Synthetic biodegradable polymers as orthopedic devices10.1016/S0142-9612(00)00101-0 ↗
34. Fixation
35. Intratunnel anterior cruciate ligament graft fixation
36. Biabsorbable fixation: scientific, technical and clinical concepts10.1097/SCS.0b013e318207432f ↗
37. Cost analysis of outpatient Anterior cruciate ligament reconstruction. Autograft versus allograft10.1007/s11999-009-1178-y ↗
38. Competitiveness of chitosan-based implants10.1016/j.ctmat.2015.03.001 ↗
39. Bone regenerative medicine: classic options, novel strategies, and future directions10.1186/1749-799X-9-18 ↗
40. Biodegradable orthopedic implants
41. Systematic approach from porto school
42. Bioabsorbable implants in orthopaedics10.1016/S0268-0890(99)90007-5 ↗
43. Effect of meniscal and focal cartilage lesions on patient-reported outcome after anterior cruciate ligament reconstruction. A nationwide cohort study from Norway and Sweden of 8476 patients with 2-year follow-up10.1177/0363546512473571 ↗
44. Economic analyses in anterior cruciate ligament reconstruction. A qualitative and systematic review10.1177/0363546515581470 ↗
45. Failure of anterior cruciate ligament reconstruction
46. Bioabsorbable versus metallic interference screw fixation in anterior cruciate ligament reconstruction: a meta-analysis of randomized controlled trials10.1016/j.arthro.2009.12.011 ↗
47. Clinical and operative characteristics of Cyclops syndrome after double-bundle anterior cruciate ligament reconstruction10.1016/j.arthro.2010.02.034 ↗
48. Revision ACL reconstruction
49. Material properties and composition of soft-tissue fixation10.1016/j.arthro.2009.12.026 ↗
50. Bioabsorbable polymers: materials technology and surgical applications10.1243/0954411981533872 ↗
51. Integrating health economics into the product development cycle: a case study of absorbable pins for treating Hallux Valgus10.1177/0272989X10388041 ↗
52. Failure of anterior cruciate ligament reconstruction10.1016/j.csm.2012.08.015 ↗