Parametric finite element modeling of reinforced polymeric leaflets for improved durability
Source abstract
Abstract
Hyaluronic acid-enhanced polyethylene polymeric TAVR shows excellent in vivo anti-calcific, anti-thrombotic, and in vitro hydrodynamic performance. However, during durability testing, impact wear and fatigue cause early valve failure. Heart valve durability can be improved by strengthening the leaflet with fiber reinforcement. A thin plastic sheet is assembled into a cylindrical form by welding two ends, which never fails during accelerated wear testing (ISO 5840-2005). The weld at the commissure post region of the leaflet (ROI) is mechanically stronger than the rest of the leaflet, which protects this region. Braided polyester fibers are embedded on the leaflet regions of the commissure post perpendicular to the valve circumference, mimicking the weld but at a much higher strength. Leaflet durability skyrockets from a few million cycles to 73 million and comparable hemodynamics performances. The entire cardiac cycle of the heart valve with embedded fibers of varying angles, lengths, and numbers is simulated in Finite Element Analysis (FEA) to study their effects on leaflet maximum principal stress and leaflet opening dynamics. Horizontal fibers wrap the leaflet 360° to relax the leaflet completely during peak diastolic. However, the leaflet has a higher coaptation gap and lower geometric orifice area (GOA). The heart valve with embedded horizontal fibers is physically manufactured and tested in an in vitro flow loop and wear tester, which shows improved durability but compromised hemodynamics. The parametric study further predicts that 12 mm long fibers covering only the commissure post region of the leaflet have low principal stress, maximum GOA, and fastest opening as the spring-like fibers help leaflet opening.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Asphalt Pavement Performance Evaluation · Polymer Nanocomposites and Properties · Infrastructure Maintenance and Monitoring
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (20)
Show source-provided references
1. A geometry optimization framework for transcatheter heart valve leaflet design10.1016/j.jmbbm.2019.103491 ↗
2. Design consideration of a novel polymeric transcatheter heart valve through computational modeling10.1016/j.jmbbm.2022.105434 ↗
3. Bui, Hieu T., Khair, Nipa, Yeats, Breandan, Gooden, Shelley, James, Susan P., Dasi, Lakshmi Prasad, Transcatheter heart valves: A biomaterials perspective. Adv. Heal. Mater. (ISSN: 2192-2659) 2100115, _eprint: https://onlinelibrary.wiley.com/doi/pdf/10.1002/adhm.202100115.
4. Bioinspired heart valve prosthesis made by silicone additive manufacturing10.1016/j.matt.2019.05.013 ↗
5. Five-year clinical outcome and valve durability after transcatheter aortic valve replacement in high-risk patients10.1161/CIRCULATIONAHA.118.036866 ↗
6. Mesostructures of the aortic valve
7. Gallocher · 2007
8. Simulation of self expanding transcatheter aortic valve in a realistic aortic root: Implications of deployment geometry on leaflet deformation10.1007/s10439-014-1051-3 ↗
9. In vitro hemodynamic assessment of a novel polymeric transcatheter aortic valve10.1016/j.jmbbm.2019.06.016 ↗
10. Epidemiology of valvular heart disease in the adult10.1038/nrcardio.2010.202 ↗
11. Mechanical considerations for polymeric heart valve development: Biomechanics, materials, design and manufacturing10.1016/j.biomaterials.2019.119493 ↗
12. Effect of fiber orientation on the stress distribution within a leaflet of a polymer composite heart valve in the closed position10.1016/j.jbiomech.2006.04.015 ↗
13. A constitutive model of ovine left and right ventricles biaxial mechanical properties10.1096/fasebj.2018.32.1_supplement.895.3 ↗
14. A new transcatheter heart valve concept (the TRISKELE): feasibility in an acute preclinical model10.4244/EIJV12I7A148 ↗
15. In vitro hydrodynamic assessment of a new transcatheter heart valve concept (the TRISKELE)10.1007/s12265-016-9722-0 ↗
16. In-vivo assessment of a novel polymer (SIBS) trileaflet heart valve
17. Stent and leaflet stresses in 26-mm, third-generation, balloon-expandable transcatheter aortic valve10.1016/j.jtcvs.2018.04.115 ↗
18. CRT-700.20 foldax TRIA TAVI: A novel-polymer transcatheter aortic valve: Pilot chronic ovine model study
19. Effects of short fiber tip geometry and inhomogeneous interphase on the stress distribution of rubber matrix sealing composites10.1002/app.41638 ↗
20. 14:00-17:00,, 2013. ISO 5840-3:2013, URL https://www.iso.org/cms/render/live/en/sites/isoorg/contents/data/standard/05/13/51313.html.