journal article·2020-09

On-site testing of sutured organs: An experimental set up to cyclically tighten sutures

Giulia Pascoletti, Maria Chiara Pressanto, Giovanni Putame, Mara Terzini, Alberto L. Audenino, Elisabetta M. Zanetti

Publisher page

Abstract

A number of surgical practices are aimed to compensate for tissue relaxation or weakened/atrophied muscles by means of suture prostheses/thread lifts. The success rate of these procedures is often very good in the short term, while it is quite variable among subjects and techniques in the middle-long term. Middle-long term failures are mostly related to suture distraction, loosening or wear, coming from repeated loading cycles. In this work, an experimental device to perform ex vivo tests on prosthetic sutures has been set up. An equine laryngoplasty has been used as a benchmark, being representative of sutures aimed to compensate for atrophied muscles. The peculiarity of this experimental set up is that the suture is on-site and it has been tightened with known, repeated loads, which do not depend on thread deformation at different load levels. Preliminary tests have been performed applying over 3000 load cycles and finally a tensile test up to rupture. Force/displacement curves obtained with this experimental set up have been reported and parameters useful to classify the biomechanical performance of sutures versus time (mainly its creep behaviour), have been outlined. Results have outlined that the organ-suture system undergoes significant creep over 3000 cycles, and this should be taken into account in order to foresee its long-term behaviour; in addition, the suture anchorage to cartilage should be improved. The experimental set up can be used to perform on-site testing of sutures, taking into account the compliance and creep response at both suture anchorage ends, in order to compare different surgeries and different kinds of thread.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Surgical Sutures and Adhesives · Reconstructive Surgery and Microvascular Techniques · Voice and Speech Disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. Additional secure circular suture during sphincteroplasty - preliminary results on the efficacy of fecal incontinence surgery in urogynecological patients10.5603/GP.2019.0014 ↗
2. In vitro mechanical testing of an alternate laryngoplasty system(ALPS) for horses10.1111/j.1532-950X.2012.01061.x ↗
3. Biomechanical comparison of 2 anterior cruciate ligament graft preparation techniques for tibial fixation: response10.1177/0363546515601386 ↗
4. ACL graft constructs: in-vitro fatigue testing highlights the occurrence of irrecoverable lengthening and the need for adequate (pre)conditioning to avert the recurrence of knee instability10.3233/THC-2006-144-515 ↗
5. Traitement du ptosis congénital par suspension au muscle frontal par fil de polypropyléne: résultats d’une étude de 21 cas10.1016/j.jfo.2014.01.014 ↗
6. Ex vivo biomechanical stability of 5 cricoid-suture constructs for equine laryngoplasty10.1111/vsu.12671 ↗
7. Long-term outcomes of chordal replacement with expanded polytetrafluoroethylene sutures to repair mitral leaflet prolapse
8. Long-term outcome of laparoscopic rectopexy for full-thickness rectal prolapse10.1007/s10151-018-1913-z ↗
9. Long-term survey of laryngoplasty and ventriculocordectomy in an older, mixed-breed population of 200 horses. Part 1: maintenance of surgical arytenoid abduction and complications of surgery10.2746/042516403776014172 ↗
10. Ossification of laryngeal structures as indicators of age10.1111/j.1556-4029.2008.00793.x ↗
11. Therapeutic algorithm for congenital ptosis repair with levator resection and frontalis suspension: results and literature review10.1080/08820538.2017.1297840 ↗
12. Retrospective comparison of outcomes of laparoscopic pyeloplasty using barbed suture versus nonbarbed suture: a single-center experience10.4103/UA.UA_123_15 ↗
13. In vitro tensile strength study on suturing technique and material10.1563/aaid-joi-D-16-00164 ↗
14. Thread-lift sutures: still in the lift? A systematic review of the literature10.1097/PRS.0000000000004101 ↗
15. Thread-lift sutures: anatomy, technique, and review of current literature10.1016/j.joms.2019.11.011 ↗
16. Sling arytenoid adduction10.1007/s00405-010-1429-2 ↗
17. Biomechanical evaluation of suture buttons versus cortical screws in the Latarjet–Bristow procedure: a fresh-frozen cadavers study10.1007/s00402-019-03269-6 ↗
18. Mechanical comparison of 3 anchoring techniques in the muscular process for laryngoplasty in the equine larynx10.1111/j.1532-950X.2014.12248.x ↗
19. Short-term outcomes of nonrobotic single-incision laparoscopic sacrocolpopexy: a surgical technique10.1016/j.jmig.2019.09.069 ↗
20. Suture wear particles cause a significant inflammatory response in a murine synovial airpouch model10.1186/s13018-018-1026-4 ↗
21. Functional outcomes of endoscopic arytenoid abduction lateropexy for unilateral vocal cord paralysis with dyspnea10.1007/s00405-017-4696-3 ↗
22. Comparison of pullout button versus suture anchor for zone I flexor tendon repair10.1016/j.jhsa.2005.10.020 ↗
23. Material properties of common suture materials in orthopaedic surgery
24. Laparoscopic pectopexy with burch colposuspension for pelvic prolapse associated with stress urinary incontinence
25. Types of materials for frontalis sling surgery for congenital ptosis
26. In vitro comparison of two techniques for suture prosthesis placement in the muscular process of the equine arytenoid cartilage10.1111/j.1532-950X.2005.00111.x ↗
27. In vitro evaluation of a novel prosthesis for laryngoplasty of horses with recurrent laryngeal neuropathy10.2746/042516400777611991 ↗
28. Experimental evaluation of suture support in bladder-neck suspension for the treatment of female stress urinary incontinence10.1089/end.2005.9934 ↗
29. Thread-lifts: a double-edged suture? A comprehensive review of the literature10.1097/DSS.0000000000001921 ↗
30. Equine laryngoplasty sutures undergo increased loading during coughing and swallowing10.1111/j.1532-950X.2010.00742.x ↗