journal article·2020-10

Finite element modeling of multiple water droplets impact onto a rough surface: Re-assessing Sa and surface wavelength

J. Xie, P. Chen, D. Rittel

Publisher page

Abstract

Waterjet peening is a promising green technology for roughening the metallic surface of orthopedic and dental implants in order to promote osseointegration. The current conventional surface characterization is essentially based on the arithmetic mean height (Sa), without additional considerations, in particular the effective surface area. Yet, this parameter together with the surface energy, is determinant for the cell-implant interaction. The influence of waterjet peening on the surface topography is investigated numerically by generating 9 rough surfaces with different initial Sa and wavelength λ. Among the selected topography descriptors, the maximum pit depth Sv might be more viable for characterizing the evolution of the rough surface compared to the other 3 roughness parameters, Sa, maximum peak height Sp and maximum height Sz. The Power Spectrum Density of peened surfaces increases overall, compared to the untreated surfaces irrespective of initial Sa0 and λ0. An analytical formula was derived by simplifying a representative single valley as a half ellipsoid, emphasizing the more influential role of the wavelength λ compared to Sa in determining the effective surface area for cell adhesion.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Erosion and Abrasive Machining · Bone Tissue Engineering Materials · Endodontics and Root Canal Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (36)

Show source-provided references
1. Oral implant surfaces: Part 1--review focusing on topographic and chemical properties of different surfaces and in vivo responses to them
2. Anderson · 2005
3. Abrasive waterjet peening: a new method of surface preparation for metal orthopedic implants10.1002/1097-4636(200009)53:5<536::AID-JBM13>3.0.CO;2-V ↗
4. Waterjet and abrasive waterjet surface treatment of titanium: a comparison of surface texture and residual stress10.1016/S0043-1648(01)00826-2 ↗
5. Quantitative characterization of surface topography using spectral analysis analysis
6. The influence of nanostructured features on bacterial adhesion and bone cell functions on severely shot peened 316L stainless steel10.1016/j.biomaterials.2015.09.019 ↗
7. Roughening of metallic biomaterials by abrasiveless waterjet peening: characterization and viability10.1016/j.wear.2011.01.024 ↗
8. Contact mechanics of rough surfaces in tribology: multiple asperity contact10.1023/A:1019186601445 ↗
9. Statistical correlation between cell adhesion and proliferation on biocompatible metallic materials10.1002/jbm.a.30212 ↗
10. The areal field parameters
11. A general overview of waterjet surface treatment modeling
12. Dassault Systèmes Simulia Corporation
13. Determination of the johnson-cook material parameters using the SCS specimen10.1007/s11340-008-9201-x ↗
14. Calculation of the power spectral density from surface profile data10.1364/AO.34.000201 ↗
15. Determination of JWL parameters for non-ideal explosive10.1063/1.1780246 ↗
16. A modeling study of metal cutting with abrasive waterjets10.1115/1.3225682 ↗
17. A constitutive model and data for metals subjected to large strains, high strain rates and high temperatures
18. Residual stress induced by waterjet peening: a finite element analysis10.1115/1.1767175 ↗
19. On the fatigue behavior of medical Ti6Al4V roughened by grit blasting and abrasiveless waterjet peening10.1016/j.jmbbm.2016.07.011 ↗
20. Hierarchical micro-nano structured Ti6Al4V surface topography via two-step etching process for enhanced hydrophilicity and osteoblastic responses10.1016/j.msec.2016.12.064 ↗
21. Topography influences adherent cell regulation of osteoclastogenesis10.1177/0022034515616760 ↗
22. On the nature of surface roughness with application to contact mechanics, sealing, rubber friction and adhesion10.1088/0953-8984/17/1/R01 ↗
23. Potential bone to implant contact area of short versus standard implants10.1097/ID.0000000000000357 ↗
24. The bone-implant interface - nanoscale analysis of clinically retrieved dental implants10.1016/j.nano.2014.05.015 ↗
25. Osseointegration and current interpretations of the bone-implant interface10.1016/j.actbio.2018.11.018 ↗
26. Fatigue of dental implants: facts and fallacies10.3390/dj4020016 ↗
27. An overview of the mechanical integrity of dental implants10.1155/2015/547384 ↗
28. Identification of failure mechanisms in retrieved fractured dental implants10.1016/j.engfailanal.2014.01.002 ↗
29. Surface roughening of metallic substrates by high pressure pure waterjet10.1016/0257-8972(95)02528-6 ↗
30. On implant surfaces: a review of current knowledge and opinions
31. The effects of waterjet peening on a random-topography metallic implant surface10.1016/j.euromechsol.2018.03.022 ↗
32. A two-dimensional model for metallic surface roughness resulting from pure waterjet peening10.1016/j.ijengsci.2017.08.010 ↗
33. Three-dimensional stochastic modeling of metallic surface roughness resulting from pure waterjet peening10.1016/j.ijengsci.2017.08.011 ↗
34. Modeling the topographic evolution of a rough metallic surface resulting from impact of water droplets10.1016/j.ijengsci.2019.103142 ↗
35. The ellipsoidal area ratio: an alternative anisotropy index for diffusion tensor imaging10.1016/j.mri.2008.07.018 ↗
36. The effect of autocorrelation length on the real area of contact and friction behavior of rough surfaces10.1063/1.1914947 ↗