journal article·2022-12

Regional variation in the mechanical properties of the skeletal muscle

Clément Simon, Mustapha Zidi

Publisher page

Abstract

Regional mechanics of skeletal muscle were investigated from equibiaxial testing in vitro on tissue samples. Samples were collected in three excising zones in transversal direction to the myofibers. Thus, the transverse plane stiffness, likely to be dictated by extracellular matrix collagen (ECM), was studied. For that, distal, middle, and proximal samples of healthy brachial biceps of rats have been tested. Data was used to generate the material parameters of the first order Ogden constitutive model at these different zones of skeletal muscle. In addition to having a nonlinear mechanical behavior, the analysis of the material parameters of the model showed that the stiffness value of the skeletal muscle tissue may on average have doubled depending on the collected sample location (p < 0.001). Furthermore, it was also shown that during the tests, when the storage temperature of the samples increases from 22 °C to 37 °C, the stiffness of the muscle tissue becomes more important (p < 0.05), which may be due to the rigor mortis phenomenon. Thus, these results contribute to investigating the regional change of mechanical properties of skeletal muscle, particularly those of ECM that play a major role in stiffness tissue, which is essential for the development of accurate computational models.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Elasticity and Material Modeling · Tendon Structure and Treatment · Myofascial pain diagnosis and treatment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. Phenomenological consequences of sectioning and bathing on passive muscle mechanics of the New Zealand white rabbit tibialis anterior
2. A Constitutive Framework for Human Dermis Mechanical Modelling
3. Aponeurosis length And fascicle insertion angles of the biceps brachii10.1142/S0219519402000484 ↗
4. A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachii10.1016/j.jbiomech.2004.04.009 ↗
5. Passive transverse mechanical properties of skeletal muscle under in vivo compression10.1016/S0021-9290(01)00083-5 ↗
6. Ultrastructure and biomechanics of skeletal muscle ECM
7. Biomechanical characterization of human dura mater10.1016/j.jmbbm.2017.12.023 ↗
8. Gras · 2012 · vol. 9
9. Hyper-elastic properties of the human sternocleidomastoideus muscle in tension10.1016/j.jmbbm.2012.06.013 ↗
10. A mathematical modeling for in vitro skeletal muscle behavior in shear deformation modes
11. Passive mechanics of muscle tendinous junction of canine diaphragm10.1152/japplphysiol.00816.2004 ↗
12. Mechanical and microstructural changes of skeletal muscle following immobilization and/or stroke10.1007/s10237-019-01196-4 ↗
13. Effect of cryopreservation at −80 °C on visco-hyperelastic properties of skeletal muscle tissue10.1016/j.jmbbm.2017.10.006 ↗
14. Development of rigor mortis is not affected by muscle volume10.1016/S0379-0738(00)00406-0 ↗
15. Differential rigor development in red and white muscle revealed by simultaneous measurement of tension and stiffness
16. Direct measurement of the direction-dependent mechanical behaviour of skeletal muscle extracellular matrix10.1016/j.actbio.2020.12.050 ↗
17. Experimental evaluation of rigor mortis V. Effect of various temperatures on the evolution of rigor mortis10.1016/0379-0738(81)90184-5 ↗
18. Effects of cold and hot water immersion on the mechanical properties of human muscle and tendon in vivo10.1016/j.clinbiomech.2004.11.005 ↗
19. 3D finite element models from serial section histology of skeletal muscle tissue − the role of micro-architecture on mechanical behaviour10.1016/j.jmbbm.2020.104109 ↗
20. Predicting muscle tissue response from calibrated component models and histology-based finite element models10.1016/j.jmbbm.2021.104375 ↗
21. Computer vision-based evaluation of pre- and postrigor changes in size and shape of atlantic cod (Gadus morhua) and atlantic salmon (Salmo salar) fillets during rigor mortis and ice storage: effects of perimortem handling stress10.1111/j.1750-3841.2007.00626.x ↗
22. Influence of Muscle Cooling on the Passive Mechanical Properties of the Human Gastrocnemius Muscle
23. Tension relaxation after stretch in resting mammalian muscle fibers: stretch activation at physiological temperatures10.1016/S0006-3495(96)79702-3 ↗
24. Thermal effects on skeletal muscle tensile behavior10.1177/036354659302100407 ↗
25. The effect of temperature on the mechanical aspects of rigor mortis in a liquid paraffin model
26. Nonuniform shortening in the biceps brachii during elbow flexion10.1152/japplphysiol.00843.2001 ↗
27. Physical continuity of the perimysium from myofibers to tendons: involvement in lateral force transmission in skeletal muscle10.1016/j.jsb.2007.01.022 ↗
28. Passive skeletal muscle response to impact loading: experimental testing and inverse modelling10.1016/j.jmbbm.2013.04.016 ↗
29. Quantifying skeletal muscle properties in cadaveric test specimens: effects of mechanical loading, postmortem time, and freezer storage10.1115/1.429621 ↗
30. A validated model of passive muscle in compression10.1016/j.jbiomech.2005.10.016 ↗
31. van Turnhout · 2005
32. Investigating passive muscle mechanics with biaxial stretch10.3389/fphys.2020.01021 ↗
33. How does tissue preparation affect skeletal muscle transverse isotropy?10.1016/j.jbiomech.2016.06.034 ↗