journal article·2021-03

It's worth cleaning – The examination of the female taper could identify a particular cause of trunnionosis at revision 16 years after total hip arthroplasty

Mara Büchner, Richard B. Cook, Corina Dommann-Scherrer, Christoph Meier, Alex Dommann, Peter Wahl

Publisher page

Abstract

Adverse reaction to metal debris (ARMD) is an issue in metal-on-metal (MoM) total hip replacements (THR). It mainly affects large-head MoM THR, whereas 28-32 mm MoM pairings are associated with low long-term revision rates. However, the bearing surface is not necessarily the only cause of metal debris. This report documents with advanced analysis of the retrievals a particular cause of trunnionosis in late failure of a small diameter MoM THR and illustrates the importance of cleaning of the taper when seating the head in THR. A 65-year-old patient was revised due to ARMD 16 years after small diameter MoM THR. Debridement and exchange of the inlay and the head had been performed through an anterior approach. While the cup and the outer surface of the head were accessible to direct analysis by an optical coordinate measuring machine, the female taper had to be analysed indirectly by measuring an imprint. Wear from the cup and the head was within expected low ranges. The analysis of the female taper identified bone fragments, which contributed to trunnionosis. Failure due to ARMD after MoM THR is not necessarily caused by the bearing, but can be due to trunnionosis. Bone fragments within the taper contact in this case highlight the importance of meticulous cleaning of the taper before seating the head, to avoid trunnionosis.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. Standardized loads acting in hip implants10.1371/journal.pone.0155612 ↗
2. Wear patterns of taper connections in retrieved large diameter metal-on-metal bearings10.1002/jor.22326 ↗
3. Experimental measurement of the static coefficient of friction at the Ti–Ti taper connection in total hip arthroplasty10.1115/1.4032446 ↗
4. Systemic toxicity related to metal hip prostheses10.3109/15563650.2014.944977 ↗
5. Pseudotumour formation due to tribocorrosion at the taper interface of large diameter metal on polymer modular total hip replacements10.1016/j.arth.2013.02.009 ↗
6. Validation of an optical coordinate measuring machine for the measurement of wear at the taper interface in total hip replacement
7. Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty10.2106/JBJS.K.01352 ↗
8. Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck10.2106/JBJS.L.01042 ↗
9. What is the long-term survival for primary THA with small-head metal-on-metal bearings?10.1007/s11999.0000000000000209 ↗
10. Effects of corrosion and cleaning method on taper dimensions: an in vitro investigation10.1177/1120700018825448 ↗
11. Friction in femoral prosthesis and photoelastic model cone taper joints10.1243/PIME_PROC_1989_203_003_01 ↗
12. A systematic review of systemic cobaltism after wear or corrosion of chrome-cobalt hip implants10.1097/PTS.0000000000000220 ↗
13. A multicenter retrieval study of the taper interfaces of modular hip prostheses10.1097/00003086-200208000-00018 ↗
14. Do you have to remove a corroded femoral stem?10.1016/j.arth.2014.03.055 ↗
15. Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearing--systematic review of clinical and epidemiological studies10.1371/journal.pone.0070359 ↗
16. Impact magnitudes applied by surgeons and their importance when applying the femoral head onto the Morse taper for total hip arthroplasty10.1007/s00402-008-0660-4 ↗
17. Setting benchmark revision rates for total hip replacement: analysis of registry evidence10.1136/bmj.h756 ↗
18. Adverse reactions to metal debris in metal-on-polyethylene total hip arthroplasty using a titanium-molybdenum-zirconium-iron alloy stem10.1016/j.arth.2014.06.030 ↗
19. The influence of contamination and cleaning on the strength of modular head taper fixation in total hip arthroplasty10.1016/j.arth.2017.05.009 ↗
20. Maximizing the fixation strength of modular components by impaction without tissue damage10.1302/2046-3758.72.BJR-2017-0078.R2 ↗
21. Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear10.1302/0301-620X.93B2.25099 ↗
22. Taper junction failure in large-diameter metal-on-metal bearings10.1302/2046-3758.14.2000047 ↗
23. Metal-on-Metal compared with metal-on-polyethylene: the effect on trunnion corrosion in total hip arthroplasty10.1016/j.arth.2017.03.012 ↗
24. The effects of blood and fat on Morse taper disassembly forces
25. Large-diameter total hip arthroplasty modular heads require greater assembly forces for initial stability10.1302/2046-3758.58.BJR-2016-0044.R1 ↗
26. Elevated intra-articular cobalt and chromium levels in mechanically assisted crevice corrosion in metal-on-polyethylene total hip arthroplasty10.1016/j.arth.2016.11.056 ↗
27. Effects of seating load magnitude on incremental cyclic fretting corrosion in 5 degrees 40' mixed alloy modular taper junctions10.1016/j.arth.2018.01.039 ↗
28. Increased mortality in metal-on-metal versus non-metal-on-metal primary total hip arthroplasty at 10 Years and longer follow-up: a systematic review and meta-analysis10.1371/journal.pone.0156051 ↗
29. Assessment of head displacement and disassembly force with increasing assembly load at the head/trunnion junction of a total hip arthroplasty prosthesis10.1016/j.arth.2016.11.054 ↗
30. Influence of assembly procedure and material combination on the strength of the taper connection at the head-neck junction of modular hip endoprostheses10.1016/j.clinbiomech.2011.08.002 ↗
31. Histopathological characterization of corrosion product associated adverse local tissue reaction in hip implants: a study of 285 cases10.1186/s12907-016-0025-9 ↗
32. What the surgeon can do to reduce the risk of trunnionosis in hip arthroplasty: recommendations from the literature10.3390/ma13081950 ↗
33. In-vivo volumetric wear rate of modern metal-metal bearings
34. Quantitative assessment of walking activity after total hip or knee replacement10.2106/00004623-199801000-00010 ↗
35. Effect of the support systems' compliance on total hip modular taper seating stability10.1177/0954411918790282 ↗
36. Analysis of 118 second-generation metal-on-metal retrieved hip implants10.1302/0301-620X.81B1.0810046 ↗
37. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements10.1243/0954411011533724 ↗
38. Failure rates of stemmed metal-on-metal hip replacements: analysis of data from the National Joint Registry of England and Wales10.1016/S0140-6736(12)60353-5 ↗
39. Fretting corrosion of CoCrMo and Ti6Al4V interfaces10.1016/j.biomaterials.2012.04.015 ↗
40. 3D linear and volumetric wear measurement on artificial hip joints—Validation of a new methodology10.1016/j.precisioneng.2010.06.001 ↗
41. Influence of contaminants in the stem—ball interface on the static fracture load of ceramic hip joint ball heads10.1243/09544119JEIM374 ↗
42. Adverse local tissue reactions in metal-on-polyethylene total hip arthroplasty due to trunnion corrosion: the risk of misdiagnosis10.1302/0301-620X.97B8.34682 ↗
43. Nano-analyses of wear particles from metal-on-metal and non-metal-on-metal dual modular neck hip arthroplasty10.1016/j.nano.2016.11.003 ↗