Improving the hemocompatibility of a porohyperelastic layered vascular graft using luminal reversal microflows
Source abstract
Abstract
Vascular graft thrombosis is a long-standing clinical problem. A myriad of efforts have been devoted to reducing thrombus formation following bypass surgery. Researchers have primarily taken a chemical approach to engineer and modify surfaces, seeking to make them more suitable for blood contacting applications. Using mechanical forces and surface topology to prevent thrombus formation has recently gained more attention. In this study, we have designed a bilayered porous vascular graft capable of repelling platelets and destabilizing absorbed protein layers from the luminal surface. During systole, fluid penetrates through the graft wall and is subsequently ejected from the wall into the luminal space (Luminal Reversal Flow - LRF), pushing platelets away from the surface during diastole. In-vitro hemocompatibility tests were conducted to compare platelet deposition in high LRF grafts with low LRF grafts. Graft material properties were determined and utilized in a porohyperelastic (PHE) finite element model to computationally predict the LRF generation in each graft type. Hemocompatibility testing showed significantly lower platelet deposition values in high versus low LRF generating grafts (median±IQR = 5,708 ± 987 and 23,039 ± 3,310 platelets per mm2, respectively, p=0.032). SEM imaging of the luminal surface of both graft types confirmed the quantitative blood test results. The computational simulations of high and low LRF generating grafts resulted in LRF values of -10.06 μm/s and -2.87 μm/s, respectively. These analyses show that a 250% increase in LRF is associated with a 75.2% decrease in platelet deposition. PHE vascular grafts with high LRF have the potential to improve anti-thrombogenicity and reduce thrombus-related post-procedure complications. Additional research is required to overcome the limitations of current graft fabrication technologies that further enhance LRF generation.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Cardiac Valve Diseases and Treatments · Cardiac and Coronary Surgery Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (56)
Show source-provided references
1. Cold-stored venous allografts in different preserving solutions: A study on changes in vein wall morphology10.1177/1457496918783728 ↗
2. Species determination using the red blood cells morphometry in domestic animals10.14202/vetworld.2016.960-963 ↗
3. Heparin induced thrombocytopenia: diagnosis and management update10.1136/pgmj.2007.059188 ↗
4. Conjugation with RGD peptides and incorporation of vascular endothelial growth factor are equally efficient for biofunctionalization of tissue-engineered vascular grafts10.3390/ijms17111920 ↗
5. Immobilized carbonic anhydrase on hollow fiber membranes accelerates co(2) removal from blood10.1016/j.memsci.2012.02.006 ↗
6. A new method for decision making in multi-objective optimization problems10.1590/S0101-74382012005000014 ↗
7. Improvements in GORE-TEX vascular graft performance by Carmeda BioActive surface heparin immobilization10.1053/ejvs.2002.1909 ↗
8. Mechanical alterations of electrospun poly(ϵ-caprolactone) in response to convective thermobonding10.1002/jbm.b.35181 ↗
9. Optimizing the porohyperelastic response of a layered compliance matched vascular graft to promote luminal self-cleaning10.1115/1.4055563 ↗
10. Heparin-bonded expanded polytetrafluoroethylene vascular graft for femoropopliteal and femorocrural bypass grafting: 1-year results10.1016/j.jvs.2005.10.037 ↗
11. Role of high shear rate in thrombosis10.1016/j.jvs.2014.12.050 ↗
12. Validation of 1- and 2-mm transit-time ultrasound flow probes on mesenteric artery and aorta of rats.
13. Heparin bonded hemodialysis e-PTFE grafts result in 20 survival benefit10.1177/112972980901000303 ↗
14. In vivo PEG modification of vascular surfaces for targeted delivery10.1016/j.jvs.2011.09.081 ↗
15. Role of prosthetic conduits in coronary artery bypass grafting
16. Construction of a bilayered vascular graft with smooth internal surface for improved hemocompatibility and endothelial cell monolayer formation10.1016/j.biomaterials.2018.07.027 ↗
17. Ezeakacha, C.P., Rabbani, A., Salehi, S., Ghalambor, A., 2018. Integrated Image Processing and Computational Techniques to Characterize Formation Damage. In: SPE International Conference and Exhibition on Formation Damage Control. D012S007R004.10.2118/189509-MS ↗
18. The anticoagulant and antithrombotic mechanisms of heparin
19. In vitro platelet interactions in whole human blood exposed to biomaterial surfaces: Insights on blood compatibility10.1002/jbm.820270909 ↗
20. A small diameter, fibrous vascular conduit generated from a poly(ester urethane)urea and phospholipid polymer blend10.1016/j.biomaterials.2009.01.013 ↗
21. The blood and vascular cell compatibility of heparin-modified ePTFE vascular grafts10.1016/j.biomaterials.2012.09.046 ↗
22. In vitro and in vivo evaluation of a small-caliber coaxial electrospun vascular graft loaded with heparin and VEGF10.1016/j.ijsu.2017.06.077 ↗
23. Visualization and analysis of biomaterial-centered thrombus formation within a defined crevice under flow10.1016/j.biomaterials.2016.04.022 ↗
24. Deformationally dependent fluid transport properties of porcine coronary arteries based on location in the coronary vasculature10.1016/j.jmbbm.2012.10.002 ↗
25. In vitro blood compatibility of modified PDMS surfaces as superhydrophobic and superhydrophilic materials10.1002/app.13355 ↗
26. A biostable, anti-fouling zwitterionic polyurethane-urea based on pdms for use in blood-contacting medical devices10.1039/D0TB01220C ↗
27. A method for preparation of an internal layer of artificial vascular graft co-modified with salvianolic acid b and heparin10.1021/acsami.8b02602 ↗
28. Atherosclerosis10.1038/s41572-019-0106-z ↗
29. Arterial thrombus formation in cardiovascular disease10.1038/nrcardio.2011.91 ↗
30. Luminal surface microgeometry affects platelet adhesion in small-diameter synthetic grafts10.1016/j.biomaterials.2003.11.025 ↗
31. Survey of multi-objective optimization methods for engineering10.1007/s00158-003-0368-6 ↗
32. Platelet diameters in inherited thrombocytopenias: analysis of 376 patients with all known disorders10.1182/blood-2014-03-564328 ↗
33. Platelet size for distinguishing between inherited thrombocytopenias and immune thrombocytopenia: a multicentric, real life study10.1111/bjh.12349 ↗
34. The tissue-engineered vascular graft-past, present, and future10.1089/ten.teb.2015.0100 ↗
35. Blood biocompatibility enhancement of biomaterials by heparin immobilization: a review10.1097/MBC.0000000000001011 ↗
36. Active wrinkles to drive self-cleaning: A strategy for anti-thrombotic surfaces for vascular grafts10.1016/j.biomaterials.2018.11.005 ↗
37. Midterm results from a multicenter registry on the treatment of infrainguinal critical limb ischemia using a heparin-bonded ePTFE graft10.1016/j.jvs.2009.12.042 ↗
38. End-point immobilization of heparin on plasma-treated surface of electrospun polycarbonate-urethane vascular graft10.1016/j.actbio.2017.01.012 ↗
39. Dynamic modeling of the formation damage and mud cake deposition using filtration theories coupled with SEM image processing10.1016/j.jngse.2017.02.047 ↗
40. Biomaterials for vascular tissue engineering10.2217/rme.09.77 ↗
41. Large elastic deformations of isotropic materials VII. Experiments on the deformation of rubber
42. Dacron vs. PTFE as bypass materials in peripheral vascular surgery–systematic review and meta-analysis10.1186/1471-2482-8-22 ↗
43. Platelet adhesion under flow10.1080/10739680802651477 ↗
44. A meta-analysis to compare dacron versus polytetrafluroethylene grafts for above-knee femoropopliteal artery bypass10.1016/j.jvs.2014.05.049 ↗
45. Small-diameter vascular tissue engineering10.1038/nrcardio.2013.77 ↗
46. Slaughter · 2002
47. Smith · 2009
48. Long term performance of small-diameter vascular grafts made of a poly(ether)urethane–polydimethylsiloxane semi-interpenetrating polymeric network
49. Computationally optimizing the compliance of multilayered biomimetic tissue engineered vascular grafts10.1115/1.4042902 ↗
50. The use of antithrombotic therapies in reducing synthetic small-diameter vascular graft thrombosis10.1177/1538574411433299 ↗
51. Monoclonal antibody-induced inhibition of platelet function: effects on hemostasis and vascular graft thrombosis in baboons
52. Coupled porohyperelastic mass transport (PHEXPT) finite element models for soft tissues using ABAQUS10.1115/1.4003489 ↗
53. Heart disease and stroke statistics-2021 update: A report from the American heart association10.1161/CIR.0000000000000950 ↗
54. Hollow fiber membrane modification with functional zwitterionic macromolecules for improved thromboresistance in artificial lungs10.1021/la504907m ↗
55. Simple surface modification of a titanium alloy with silanated zwitterionic phosphorylcholine or sulfobetaine modifiers to reduce thrombogenicity10.1016/j.colsurfb.2010.04.018 ↗
56. Surface modification of polytetrafluoroethylene (PTFE) with a heparin-immobilized extracellular matrix (ECM) coating for small-diameter vascular grafts applications10.1016/j.msec.2021.112301 ↗