journal article·2018-07

Glass -polyalkenoate cement: An alternative material for kyphoplasty in osteoporotic vertebral compression fractures – An ex vivo study

Tim Leschinger, Karsten Engel, Gert Peter Brüggemann, Viktoria Dederer, Wolfram Friedrich Neiss, Max Joseph Scheyerer, Lars Peter Müller, Kilian Wegmann

Publisher page

Abstract

Adjacent vertebral body fracture is described as a risk after vertebroplasty and kyphoplasty. It may be true that this phenomenon is caused precisely because of the frequently used polymethylmethacrylate cement (PMMA), which shows a higher level of stiffness than bone material and may ultimately lead to shifting stress levels within the entire spine. The goal of the present study was to evaluate and compare the pressure distribution in the endplate of human vertebrae after kyphoplasty with PMMA and aluminum-free glass-polyalkenoate cement (gpc). For the present study, 8 fresh frozen human cadaveric vertebral bodies from the thoracolumbar junction were used. All vertebrae were augmented transpedicularly on one side with gpc and on the other side with PMMA. A loading of 600 N, 800 N and 1000 N was applied. In the data processing an individual region of interest (roi) was generated for each vertebra. The following parameters were determined for each roi: maximum force [N], maximum pressure [kPa], mean pressure [kPa], roi area [cm2]. We found significantly higher mean pressure values in the areas of the vertebrae augmented with PMMA, compared to the ones after augmentation with gpc (p = 0.012) when applying 1000 N. In the groups with lower forces there were no statistical relevant differences. The pressure distribution shows an advantage for gpc. A material, which does not create load concentration onto the cranial and caudal vertebral surface, could have major advantages concerning the risk of adjacent vertebral fractures. Thus the results of the 1000 N loading protocol suggest gpc being a possible alternative to ordinary PMMA cement, regarding its influence on stiffness in kyphoplasty. These and other general aspects like incorporation should be addressed and elaborated more detailed in further studies.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Spinal Fractures and Fixation Techniques · Spine and Intervertebral Disc Pathology · Pelvic and Acetabular Injuries

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (49)

Show source-provided references
1. In vitro comparative assessment of the mechanical properties of PMMA cement and a GPC cement for vertebroplasty10.1016/j.jor.2016.01.002 ↗
2. Percutaneous vertebroplasty: functional improvement in patients with osteoporotic compression fractures10.1097/01.brs.0000216487.97965.38 ↗
3. The effect on anterior column loading due to different vertebral augmentation techniques10.1016/j.clinbiomech.2004.09.004 ↗
4. The fracture risk of adjacent vertebrae is increased by the changed loading direction after a wedge fracture10.1097/BRS.0b013e3181f0f726 ↗
5. Predictive equations for lumbar spine loads in load-dependent asymmetric one- and two-handed lifting activities10.1016/j.clinbiomech.2011.12.015 ↗
7. Load shift of the intervertebral disc after a vertebroplasty: a finite-element study10.1007/s00586-002-0512-9 ↗
8. An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty10.1097/00007632-200107150-00008 ↗
9. The effect of osteoporotic vertebral fracture on predicted spinal loads in vivo10.1007/s00586-006-0158-0 ↗
10. Prediction of the compressive strength of human lumbar vertebrae10.1016/0268-0033(89)90071-5 ↗
11. A randomized trial of vertebroplasty for painful osteoporotic vertebral fractures10.1056/NEJMoa0900429 ↗
12. Influence of formalin fixation on the biomechanical properties of human diaphyseal bone10.1515/bmt.2010.043 ↗
13. Incidence of fracture in adjacent levels in patients treated with balloon kyphoplasty: a review of the literature10.1007/s12178-007-9007-y ↗
14. Public health impact of osteoporosis10.1093/gerona/glt093 ↗
15. Cement distribution, volume, and compliance in vertebroplasty: some answers from an anatomy-based nonlinear finite element study10.1097/BRS.0b013e31817c750b ↗
16. Management of acute osteoporotic vertebral fractures: a nonrandomized trial comparing percutaneous vertebroplasty with conservative therapy10.1016/S0002-9343(02)01524-3 ↗
17. A randomized trial comparing balloon kyphoplasty and vertebroplasty for vertebral compression fractures due to osteoporosis10.3174/ajnr.A4127 ↗
18. Age- and gender-related differences in vertebral bone mass, density, and strength10.1359/jbmr.1999.14.8.1394 ↗
19. Incidence of subsequent vertebral fracture after kyphoplasty10.1097/01.brs.0000142469.41565.2a ↗
20. Augmentation of mechanical properties in osteoporotic vertebral bones--a biomechanical investigation of vertebroplasty efficacy with different bone cements10.1007/s005860000204 ↗
21. Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studies10.1097/01.brs.0000229254.89952.6b ↗
22. An estimate of the worldwide prevalence and disability associated with osteoporotic fractures10.1007/s00198-006-0172-4 ↗
23. A randomized trial of vertebroplasty for osteoporotic spinal fractures10.1056/NEJMoa0900563 ↗
24. Prophylactic vertebroplasty: cement injection into non-fractured vertebral bodies during percutaneous vertebroplasty10.1016/j.acra.2008.05.005 ↗
25. Risks and benefits of percutaneous vertebroplasty or kyphoplasty in the management of osteoporotic vertebral fractures10.1007/s00198-013-2574-4 ↗
26. Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty10.1097/00007632-200107150-00009 ↗
27. Risk of new vertebral fracture in the year following a fracture10.1001/jama.285.3.320 ↗
28. Characteristics of a prevalent vertebral deformity predict subsequent vertebral fracture: results from the European prospective osteoporosis study (EPOS)10.1016/S8756-3282(03)00248-5 ↗
29. Influence of formalin fixation on the implant stability quotient and mechanical characteristics of bone10.1016/j.bjoms.2012.08.009 ↗
30. Vertebroplasty and kyphoplasty are associated with an increased risk of secondary vertebral compression fractures: a population-based cohort study10.1007/s00198-008-0745-5 ↗
31. Percutaneous vertebroplasty: long-term clinical and radiological outcome10.1007/s00234-002-0856-1 ↗
32. Kyphoplasty in osteoporotic vertebral compression fractures--guidelines and technical considerations10.1186/1749-799X-6-43 ↗
33. An ex vivo exothermal and mechanical evaluation of two-solution bone cements in vertebroplasty10.1016/j.spinee.2011.02.012 ↗
34. Spinal loads after osteoporotic vertebral fractures treated by vertebroplasty or kyphoplasty10.1007/s00586-005-0018-3 ↗
35. Economic burden of osteoporosis-related fractures in Medicaid10.1111/j.1524-4733.2006.00161.x ↗
36. Experiences with cement leakage after balloon kyphoplasty10.1007/s00132-012-1964-1 ↗
37. Stabilization of the pelvic ring with photodynamic bone stabilization (IlluminOss)
38. New fractures after vertebroplasty: adjacent fractures occur significantly sooner
39. The Photodynamic Bone Stabilization System: a minimally invasive, percutaneous intramedullary polymeric osteosynthesis for simple and complex long bone fractures
40. The biomechanical effects of kyphoplasty on treated and adjacent nontreated vertebral bodies10.1097/01.bsd.0000138694.56012.ce ↗
41. Percutaneous vertebroplasty compared with optimal pain medication treatment: short-term clinical outcome of patients with subacute or chronic painful osteoporotic vertebral compression fractures. The VERTOS study
42. In vivo loads in the lumbar L3-4 disc during a weight lifting extension10.1016/j.clinbiomech.2013.11.018 ↗
43. Treatment of painful osteoporotic vertebral fractures with percutaneous vertebroplasty or kyphoplasty10.1007/s001980170086 ↗
44. The role of polymethylmethacrylate bone cement in modern orthopaedic surgery10.1302/0301-620X.89B7.19148 ↗
45. Biomechanical evaluation of the primary stability of pedicle screws after augmentation with an innovative bone stabilizing system10.1007/s00402-013-1842-2 ↗
46. Biomechanical evaluation of vertebroplasty and kyphoplasty with polymethyl methacrylate or calcium phosphate cement under cyclic loading10.1097/01.brs.0000248423.28511.44 ↗
47. New in vivo measurements of pressures in the intervertebral disc in daily life10.1097/00007632-199904150-00005 ↗
48. Decreased extrusion of calcium phosphate cement versus high viscosity PMMA cement into spongious bone marrow-an ex vivo and in vivo study in sheep vertebrae10.1016/j.spinee.2016.07.529 ↗
49. Balloon kyphoplasty versus percutaneous vertebroplasty for treatment of osteoporotic vertebral compression fractures (OVCFs)10.1007/s00198-016-3610-y ↗