journal article·2022-09

Assigning trabecular bone material properties in finite element models simulating the pelvis before and after the development of peri-prosthetic osteolytic lesions

Thomas M. Grace, Lucian B. Solomon, Gerald J. Atkins, Dominic Thewlis, Mark Taylor

Publisher page

Abstract

Estimating strain distribution in the acetabulum before and after the development of peri-prosthetic osteolytic lesions secondary to total hip arthroplasty may assist with understanding the pathogenesis of this condition. This could be achieved by performing patient-specific finite element analysis of (1) total hip arthroplasty recipients with developed acetabular osteolytic lesions, and (2) models simulating the patient's pelvis and implant immediately after primary surgery. State of the art patient-specific total hip arthroplasty finite element analysis simulations obtain trabecular bone material properties from Hounsfield units within computed tomography (CT) scans of patients. However, this is not feasible when an implant is already in situ due to metal artefact disruption and, in turn, incorrectly reproduced Hounsfield units. Therefore, alternative methods of assigning trabecular bone material properties within such models were tested and strain results compared. It was found that assigning set material properties throughout the trabecular bone geometry was sufficient for the desired application. Simulating the primary implant and pelvis requires geometric and material based assumptions. Therefore, comparisons were made between strain values obtained from simulated primary models, from state of the art methods using material properties obtained from intact bone within a CT scan, and from models with osteolytic lesions. Strain values found using the finite element models simulating the pelvis before osteolytic lesion developed were considerably closer to those found using state of the art methods than those found for the bone loss models. These models could be used to determine relationships between strain distribution and factors such as bone loss.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Hip disorders and treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (49)

Show source-provided references
1. Biomechanical model of a high risk impending pathologic fracture of the femur: lesion creation based on clinically implemented scoring systems10.1016/j.clinbiomech.2013.02.011 ↗
2. Anderson · 2005
3. The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement: a preliminary study of 1000 cases investigating postoperative stability10.1302/0301-620X.88B7.17577 ↗
4. Imaging evaluation of complications of hip arthroplasty: review of current concepts and imaging findings10.1016/j.carj.2012.08.003 ↗
5. Statistical shape modelling versus linear scaling: effects on predictions of hip joint centre location and muscle moment arms in people with hip osteoarthritis10.1016/j.jbiomech.2019.01.031 ↗
6. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue10.1016/S0021-9290(03)00257-4 ↗
7. Charite–universitaetsmedizin Berlin (2008)
8. Simulation of fracture healing in the tibia: mechanoregulation of cell activity using a lattice modeling approach10.1002/jor.21362 ↗
9. Position and orientation in space of bones during movement: anatomical frame definition and determination10.1016/0268-0033(95)91394-T ↗
10. Bone remodeling characteristics of a short-stemmed total hip replacement10.1016/j.arth.2008.07.014 ↗
11. Mechanical and textural properties of pelvic trabecular bone10.1016/0021-9290(93)90014-6 ↗
12. An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures10.1109/10.102791 ↗
13. OpenSim: open-source software to create and analyze dynamic simulations of movement10.1109/TBME.2007.901024 ↗
14. Calibration with or without phantom for fracture risk prediction in cancer patients with femoral bone metastases using CT-based finite element models10.1371/journal.pone.0220564 ↗
15. Revision total hip arthroplasty: epidemiology and causes
16. Metal artifact reduction in CT: where are we after four decades?10.1109/ACCESS.2016.2608621 ↗
17. A semiautomated method to quantitatively assess osteolytic lesion volume and bone mineral density within acetabular regions of interest from CT
18. A calibrated EMG-informed neuromusculoskeletal model can appropriately account for muscle co-contraction in the estimation of hip joint contact forces in people with hip osteoarthritis10.1016/j.jbiomech.2018.11.042 ↗
19. Computational assessment of press-fit acetabular implant fixation: the effect of implant design, interference fit, bone quality, and frictional properties
20. Causes of revision in young patients undergoing total hip arthroplasty10.1016/j.arth.2019.03.014 ↗
21. Development of a biofidelic human pelvic FE-model with several modifications onto a commercial use model for lateral loading conditions
22. Comparison of contact mechanics between a total hip replacement and a hip resurfacing with a metal-on-metal articulation
23. Problem of stress shielding and improvement to the hip Implat designs: a review10.3923/jms.2007.460.467 ↗
24. Periacetabular bone changes after uncemented total hip arthroplasty evaluated by quantitative computed tomography10.1080/17453670610046299 ↗
25. The effects of musculoskeletal loading regimes on numerical evaluations of acetabular component
26. Combined bone ingrowth and remodeling around uncemented acetabular component: a multiscale mechanobiology-based finite element analysis10.1115/1.4037223 ↗
27. Finite element analysis of retroacetabular osteolytic defects following total hip replacement10.1016/j.jbiomech.2013.07.038 ↗
28. Altered load transfer in the pelvis in the presence of periprosthetic osteolysis10.1115/1.4028522 ↗
29. Risk analysis of patients with an osteolytic acetabular defect after total hip arthroplasty using subject-specific finite-element modelling10.1302/0301-620X.100B11.BJJ-2018-0092.R2 ↗
30. Primary stability of a cementless acetabular cup in a cohort of patient‐specific finite element models10.1002/jor.23709 ↗
31. Biomechanical evaluation of a new fixation type in 3D-printed periacetabular implants using a finite element simulation10.3390/app9050820 ↗
32. Retroacetabular stress-shielding in THA10.1007/s11999-007-0043-0 ↗
33. Magnetic resonance imaging after total hip arthroplasty: evaluation of periprosthetic soft tissue10.2106/00004623-200409000-00013 ↗
34. Ross · 2015
35. Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitro10.1016/j.jbiomech.2007.09.009 ↗
36. Is early bone resorption around non-cemented tha cups related to stress shielding
37. Aseptic loosening, not only a question of wear: a review of different theories10.1080/17453670610045902 ↗
38. Generic rules of mechano-regulation combined with subject specific loading conditions can explain bone adaptation after THA10.1371/journal.pone.0036231 ↗
39. Initial stability of cementless acetabular cups: press-fit and screw fixation interaction--an in vitro biomechanical study10.1007/s00590-014-1571-4 ↗
40. Four decades of finite element analysis of orthopaedic devices: where are we now and what are the opportunities?10.1016/j.jbiomech.2014.12.019 ↗
41. Discrepancies in knee joint moments using common anatomical frames defined by different palpable landmarks10.1123/jab.24.2.185 ↗
42. The initial stability and contact mechanics of a press-fit resurfacing arthroplasty of the hip10.1302/0301-620X.89B4.18055 ↗
43. Measuring bone mineral density of the pelvis and proximal femur after total hip arthroplasty10.1302/0301-620X.83B2.0830283 ↗
44. Bone density adjacent to press-fit acetabular components - a prospective analysis with quantitative computed tomography10.2106/00004623-200104000-00007 ↗
45. Analysis of contact mechanics in McKee-Farrar metal-on-metal hip implants
46. Re-revision total hip arthroplasty: epidemiology and factors associated with outcomes10.1016/j.jcot.2018.08.021 ↗
47. A subject-specific pelvic bone model and its application to cemented acetabular replacements10.1016/j.jbiomech.2010.06.023 ↗
48. The MAP client: user-friendly musculoskeletal modelling workflows10.1007/978-3-319-12057-7_21 ↗
49. Patterns of osteolysis around total hip components inserted with and without cement10.2106/00004623-199503000-00013 ↗