Tubular flow diverters (FDs) represent an important subset of the endovascular treatment of cerebral aneurysms (CAs), acting to reduce aneurysm inflow, eventually resulting in aneurysm thrombosis and occlusion. eCLIPs (product of Evasc Neurovascular Enterprises, Vancouver, Canada), an innovative non-tubular implant causes flow diversion by bridging the neck of bifurcation CAs. However, in a small subset of challenging bifurcation aneurysms with fusiform pathology, the currently available eCLIPs models do not provide sufficient neck bridging resulting in a gap created between the device structure and the aneurysm/artery wall. To overcome this challenge, a new design of the eCLIPs (VR-eCLIPs) was developed by varying the rib length to cover such an inflow gap. To optimize the new product development process, and avoiding expensive and time-consuming iterative manufacture of prototype devices, we have developed a new finite element model to simulate the crimping and expansion processes of the VR-eCLIPs implant, and assess the possibility of plastic deformation. Results indicated that neither eCLIPs nor VR-eCLIPs experience plastic deformation during the crimping process. Upon full expansion, the ribs of VR-eCLIPs interact with the aneurysm and artery wall to cover the inflow gap that exists in certain challenging anatomies. This process serves as a basis to expedite design development prior to prototype manufacturing.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Intracranial Aneurysms: Treatment and Complications · Vascular Malformations Diagnosis and Treatment · Aortic Disease and Treatment Approaches

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. The effect of stents in cerebral aneurysms: a review10.4103/1793-5482.175639 ↗
2. The second-generation eCLIPs endovascular clip system: initial experience10.3171/2016.10.JNS161731 ↗
3. Finite element modelling of diseased carotid bifurcations generated from in vivo computerised tomographic angiography10.1016/j.compbiomed.2010.02.006 ↗
4. Dassault Systèmes · 2022
5. Biomechanical modeling of stents: survey 1997-200710.1016/B978-0-444-53075-2.00002-2 ↗
6. eCLIPs bifurcation remodeling system for treatment of wide neck bifurcation aneurysms with extremely low dome-to-neck and aspect ratios: a multicenter experience10.1136/neurintsurg-2020-016354 ↗
7. A finite element strategy to investigate the free expansion behaviour of a biodegradable polymeric stent10.1016/j.jbiomech.2015.03.024 ↗
8. Intracranial aneurysms10.1007/s00330-004-2614-8 ↗
9. Finite element analysis on nitinol medical applications
10. Gopal · 2008
11. A layer-specific three-dimensional model for the simulation of balloon angioplasty using magnetic resonance imaging and mechanical testing10.1114/1.1492812 ↗
12. A finite element method to predict adverse events in intracranial stenting using microstents: in vitro verification and patient specific case study10.1007/s10439-015-1505-2 ↗
13. Development of a new generation of neurovascular devices for the treatment of cerebral bifurcation aneurysms with the fusiform pathology: a computational approach
14. Cerebral aneurysm
15. Cardiovascular stent design and vessel stresses: a finite element analysis10.1016/j.jbiomech.2004.07.022 ↗
16. Finite element analysis for fatigue behaviour of a self-expanding Nitinol peripheral stent under physiological biomechanical conditions10.1016/j.compbiomed.2018.11.019 ↗
17. Three-Dimensional geometrical characterization of cerebral aneurysms10.1023/B:ABME.0000012746.31343.92 ↗
18. High fidelity virtual stenting (HiFiVS) for intracranial aneurysm flow diversion: in vitro and in silico10.1007/s10439-013-0808-4 ↗
19. Physiological remodeling of bifurcation aneurysms: preclinical results of the eCLIPs device10.3171/2016.10.JNS162024 ↗
20. Platelet dynamics and hemodynamics of cerebral aneurysms treated with flow-diverting stents10.1007/s10439-019-02368-0 ↗
21. A finite element investigation on design parameters of bare and polymer-covered self-expanding wire braided stents10.1016/j.jmbbm.2020.104305 ↗
22. Towards predicting patient-specific flow-diverter treatment outcomes for bifurcation aneurysms: from implantation rehearsal to virtual angiograms10.1007/s10439-015-1395-3 ↗
23. A virtual comparison of the eCLIPs device and conventional flow-diverters as treatment for cerebral bifurcation aneurysms10.1007/s13239-019-00424-3 ↗
24. Basilar tip aneurysms: a microsurgical and endovascular contemporary series of 100 patients10.1227/NEU.0b013e3182797952 ↗
25. Hemodynamics of cerebral aneurysms10.1146/annurev.fluid.40.111406.102126 ↗
26. Solis Eichler · 2020
27. Self-expanding Nitinol stents: material and design considerations10.1007/s00330-003-2022-5 ↗
28. Balloon expandable coronary stent materials: a systematic review focused on clinical success10.1007/s44164-022-00009-w ↗
29. Experimentally validated simulation of coronary stents considering different dogboning ratios and asymmetric stent positioning10.1371/journal.pone.0224026 ↗
30. Delivery and release of nitinol stent in carotid artery and their interactions: a finite element analysis10.1016/j.jbiomech.2007.02.024 ↗
31. Mechanical Response of Cardiovascular Stents under Vascular Dynamic Bending10.1186/s12938-016-0135-8 ↗
32. Particle image velocimetry measurements of the flow-diverting effects of a new generation of the eclips implant for the treatment of intracranial bifurcation aneurysms10.3390/app10238639 ↗
33. Current treatment strategies for intracranial aneurysms: an overview10.1177/0003319717700503 ↗