Abstract

Implant modularity within revision total hip arthroplasty (THA) offers multiple implant configurations and allows surgeons a high intraoperative flexibility to restore functionality to the patients joint, even in complex revision cases. However, a rare but devastating complication for patients, clinicians and manufacturers presenting a breakage of the taper junction between the distal stem and the proximal implant part. Aside from implant and patient specific risk factors, corrosion and fretting at the stem junctions have been associated with taper failure. Whether corrosive processes are a precursor of failure or rather an accompaniment of material fatigue is thereby still unclear. Therefore, this study aims to investigate the incidence of taper corrosion in a collection of 17 retrievals from a single type (MRP-Titan, Peter Brehm GmbH) and on the correlation of taper corrosion to implant and patient specific factors. None of the implants was revised for problems related to the taper junction, corrosion or the implant itself. The modular stem junction of all retrievals was visually rated with respect to corrosion, fretting and surface contamination. Additionally, the stability of taper junctions of retrievals where the proximal part with the neck was still assembled to the stem was determined by measuring the loosening moment of the securing screw and the push-out-force for taper dissociation. There was no difference between the mean push-out-force of the retrievals (14 kN ± 1.2 kN) and new reference samples (12.6 kN ± 0.5 kN). Approximately one third of the investigated retrievals showed considerable taper corrosion. The extent of corrosion increased with time in vivo and contamination of the neck piece, while it decreased with the loosening moment of the locking screw. The parameters femoral head offset, neck piece length, lateralized neck pieces, obesity of patients and septic/aseptic revision were not correlated to taper corrosion. Taper corrosion seems to occur regularly in modular taper junctions and is not necessarily connected to taper failure. A correct assembly of the junction and avoiding taper surface contamination during revision surgery is mandatory.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. Annual Report 2022, the Swedish Arthroplasty Register. 2022, Registercentrum Västra Götaland, 413 45 (Göteborg)..
2. The influence of contact conditions and micromotions on the fretting behavior of modular titanium alloy taper connections10.1016/j.medengphy.2012.07.013 ↗
3. Wear particles induce a new macrophage phenotype with the potential to accelerate material corrosion within total hip replacement interfaces10.1016/j.actbio.2019.10.039 ↗
4. The different failure modes of the connecting elements of the modular hip arthroplasty revision stem Revitan10.1016/j.jmbbm.2021.104778 ↗
5. Assessment of a press-fit proximal femoral modular reconstruction implant (PFMR(®)) at 14.5 years. A 48-case series with a disturbing rate of implant fracture10.1016/j.otsr.2017.11.024 ↗
6. Micromotion at the head-stem taper junction of total hip prostheses is influenced by prosthesis design-, patient- and surgeon-related factors10.1016/j.jbiomech.2019.109424 ↗
7. What can the surgeon do to reduce the risk of junction breakage in modular revision stems?10.1016/j.artd.2018.03.002 ↗
8. A multicenter retrieval study of the taper interfaces of modular hip prostheses10.1097/00003086-200208000-00018 ↗
9. Modular proximal body exchange for Re-revision total hip arthroplasty: rarely utilized and moderately successful10.1016/j.arth.2023.04.020 ↗
10. Short proximal components in modular revision stems carry a higher risk for stem fractures10.1177/1120700019884049 ↗
11. Outcome of a modular tapered uncemented titanium femoral stem in revision hip arthroplasty10.1007/s00264-015-2699-5 ↗
12. The reliability of a scoring system for corrosion and fretting, and its relationship to material loss of tapered, modular junctions of retrieved hip implants10.1016/j.arth.2013.12.003 ↗
13. Influence of material coupling and assembly condition on the magnitude of micromotion at the stem–neck interface of a modular hip endoprosthesis10.1016/j.jbiomech.2011.04.007 ↗
14. Modular tapered titanium stems in revision arthroplasty of the hip10.1302/0301-620X.98B1.36442 ↗
15. Proximal component modularity in THA--at what cost? An implant retrieval study10.1007/s11999-011-2155-9 ↗
16. Mechanical failure of 113 uncemented modular revision femoral components10.1302/0301-620X.102B5.BJJ-2019-1333.R2 ↗
17. The influence of contamination and cleaning on the strength of modular head taper fixation in total hip arthroplasty10.1016/j.arth.2017.05.009 ↗
18. Factors influencing taper failure of modular revision hip stems10.1016/j.medengphy.2018.02.001 ↗
19. Fracture of cementless femoral stems at the mid-stem junction in modular revision hip arthroplasty systems10.2106/JBJS.I.01589 ↗
20. The effects of blood and fat on Morse taper disassembly forces
21. Interaction pathways of implant metal localized corrosion and macrophage inflammatory reactions
22. Femoral stem modularity10.1016/j.otsr.2019.05.019 ↗
23. MRP-Titan - Instrumentationsanleitung. [cited 2023 29.08.2023]; Available from:: https://hq.mathysmedical.com/Storages/User/Dokumente/Operationstechnik/Huefte/PETER_BREHM_Instrumentationsanleitung_MRP-TITAN_DE.pdf.
24. Zementfreier Femurschaftwechsel mit der Modularen Revisions Prothese MRP-TITAN-Revisionsschaft10.1007/s00064-007-1195-5 ↗
25. Fatigue fracture in dual modular revision total hip arthroplasty stems: failure analysis and computed tomography diagnostics in two cases10.1016/j.arth.2013.09.008 ↗
26. Failure analysis of a modular revision total HIP arthroplasty femoral stem fractured in vivo10.1016/j.engfailanal.2020.104591 ↗
27. Does surface topography play a role in taper damage in head-neck modular junctions?10.1007/s11999-016-4933-x ↗
28. Corrosion of titanium under simulated inflammation conditions: clinical context and in vitro investigations10.1016/j.actbio.2021.10.002 ↗
29. In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants10.1002/jbm.b.31171 ↗
30. Fracture of an S-ROM stem at the sleeve-stem junction10.1016/j.artd.2018.02.004 ↗
31. Results of uncemented revision arthroplasty of the hip with the MRP-stem using an intrafemoral approach with vascularized distal fenestration10.1055/s-2002-36039 ↗
32. Femoral stem fracture in hip revision arthroplasty: a systematic literature review of the real-world evidence10.1055/a-1348-2873 ↗
33. Hypoxia and chronic lung disease10.1007/s00109-007-0280-4 ↗
34. Failure mechanisms in CoCrMo modular femoral stems for revision total hip arthroplasty10.1002/jbm.b.33693 ↗
35. Impaction grafting in the femur in cementless modular revision total hip arthroplasty: a descriptive outcome analysis of 243 cases with the MRP-TITAN revision implant10.1186/1471-2474-14-19 ↗