Indentation mechanics and native collagen content in the cartilaginous endplate: A comparison between porcine cervical and human lumbar spines
Source abstract
Abstract
This study characterized the regional indentation mechanics and native collagen content in cartilaginous endplates (CEPs) from the porcine cervical spine, young human lumbar spine, and aged human lumbar spine. Seventeen endplates were included in this study: six porcine cervical, nine young human lumbar, and two aged human lumbar. Width and depth measurements were obtained using a digital caliper and used to size-normalize and identify the central, anterior, posterior, and lateral regions. Regional microindentation tests were performed using a serial robot, where surface locations were loaded/unloaded at 0.1 mm/s and held at a constant 10 N force for 30 s. Loading stiffness and creep displacement were obtained from force-displacement data. Immunofluorescence staining for type I and type II collagen was subsequently performed on sagittal sections of all endplate regions. 255 images were obtained from which fluorescence intensity, sub-surface void area, and cartilage thickness were measured. CEPs from the young human lumbar spine were, on average, 27% more compliant, 0.891 mm thicker, had a lower fluorescence intensity for native collagen proteins within the cartilage (-58%) and subchondral bone (-24%), and had a sub-surface void area that was 19.7 times greater than porcine cervical CEPs. Compared to aged human lumbar CEPs, young human lumbar CEPs were 57% stiffer, 0.568 mm thicker, had a higher fluorescence intensity for native collagen proteins within the cartilage (+30%) and subchondral bone (+46%), and had a sub-surface void area that was 10.6 times smaller. Although not a perfect mechanical and structural surrogate, porcine cervical CEPs provided initial conditions that may be more representative of the young and healthy human lumbar spine compared to aged human cadaveric specimens. The indentation properties presented may have further applications to finite element models of the human lumbar spine.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Spine and Intervertebral Disc Pathology · Medical Imaging and Analysis · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. The human lumbar endplate. Evidence of changes in biosynthesis and denaturation of the extracellular matrix with growth, maturation, aging, and degeneration10.1097/00007632-199605150-00006 ↗
2. Structure-fuction relationships at the human spinal disc-vertebra interface10.1002/jor.23627 ↗
3. Cartilage endplate thickness variation measured by ultrashort Echo-Time MRI is associated with adjacent disc degeneration10.1097/BRS.0000000000002432 ↗
4. Bogduk · 2012
5. Sensory and sympathetic innervation of the vertebral endplate in patients with degenerative disc disease10.1302/0301-620X.79B1.0790147 ↗
6. In vitro biomechanical characteristics of the spine: a comparison between human and porcine spinal segments10.1097/BRS.0b013e3181b21885 ↗
7. Intervertebral disc herniation: studies on a porcine model exposed to highly repetitive flexion/extension motion with compressive force10.1016/S0268-0033(00)00063-2 ↗
8. Innervation of pathologies in the lumbar vertebral endplate and intervertebral disc10.1016/j.spinee.2013.06.075 ↗
9. Tensile Properties of the human annulus fibrosus
10. Biomechanical and endplate effects on nutrient transport in the intervertebral disc10.1016/j.wneu.2016.12.041 ↗
11. Exploring interactions between force, repetition and posture on intervertebral disc height loss and bulging in isolated porcine cervical functional spinal units from sub-acute-failure magnitudes of cyclic compressive loading10.1016/j.jbiomech.2015.08.023 ↗
12. The impact of posture and prolonged cyclic compressive loading on vertebral joint mechanics10.1097/BRS.0b013e318256f9e6 ↗
13. Mapping the structural properties of the lumbosacral vertebral endplates
14. Is collagen fiber damage the cause of early softening in articular cartilage?10.1016/j.joca.2012.09.002 ↗
15. A study on the structural properties of the lumbar endplate10.1097/BRS.0b013e3181a2ea0a ↗
16. Intervertebral disc regeneration: do nutrients lead the way?10.1038/nrrheum.2014.91 ↗
17. Significance of cartilage endplate within herniated disc tissue10.1007/s00586-014-3399-3 ↗
18. The role of the vertebral endplate in low back pain10.1055/s-0033-1347298 ↗
19. Correlation of vertebral strength topography with 3-dimensional computed tomographic structure10.1097/BRS.0b013e31826c670d ↗
20. An anatomic basis for spinal instability: a porcine trauma model10.1002/jor.1100090318 ↗
21. Can periods of static loading be used to enhance the resistance of the spine to cumulative compression?10.1016/j.jbiomech.2007.02.007 ↗
22. The role of load magnitude as a modifier of the cumulative load tolerance of porcine cervical spinal units: progress towards a force weighting approach10.1080/14639220500093160 ↗
23. Quantification of the relationship between load magnitude, rest duration and cumulative compressive tolerance of the spine: development of a weighting system for adjustment to a common injury exposure level10.1080/14639220701217279 ↗
24. Evaluation and prediction of human lumbar vertebrae endplate mechanical properties using indentation and computed tomography10.1115/1.4040252 ↗
25. Growth and skeletal development of the pig
26. Morphology of the human vertebral endplate10.1002/jor.21513 ↗
27. Region and strain-dependent diffusivities of glucose and lactate in healthy human cartilage endplate10.1016/j.jbiomech.2016.06.008 ↗
28. The porcine cervical spine as a model of the human lumbar spine: an anatomical, geometric, and functional comparison10.1097/00002517-199912050-00012 ↗
29. Cyclic loading history alters the joint compression tolerance and regional indentation responses in the cartilaginous endplate10.1016/j.jmbbm.2022.105542 ↗
30. Incidence of compression induced microinjuries in the cartilage endplate of the spine10.1097/BRS.0000000000004521 ↗
31. Mechanically induced histochemical and structural damage in the annulus fibrosus and cartilaginous endplate: a multi-colour immunofluorescence analysis10.1007/s00441-022-03649-2 ↗
32. Incorporating loading variability into in vitro injury analyses and its effect on cumulative compression tolerance in porcine cervical spine units10.1016/j.jbiomech.2019.03.011 ↗
33. A comparison of biomechanical properties between human and porcine cornea10.1016/S0021-9290(00)00219-0 ↗