journal article·2024-12Open access

A first step towards the detection of damage processes in endodontic Ni-Ti alloy files, using acoustic emission

Jeanne Davril, Romain Hocquel, Marin Vincent, Rémy Balthazard, Stéphane Claude, Eric Mortier, Adrien Baldit, Rachid Rahouadj

Abstract

Despite major instrumental developments over the last decade, endodontic files are still not infallible. It is well known that NiTi rotary files can break without any visible sign of deformation. Instrument breakage under combined flexion-torsion loading is still common in clinical practice. Unfortunately, breakage of this type of instrument mainly occurs in narrow canals, through pinching in the apical region. When such an incident occurs, the endodontist must adopt a debris retrieval strategy that is both stressful and not guaranteed success. This study proposes a new method for experimental damage detection leading to the fracture of Ni-Ti shape memory alloy endodontic files. It is based on the acoustic emission (AE) technique and mechanical parameters measured in real-time and image analysis. It has been shown that the AE results correlate with the damage observations and torque and force measurements recorded during the tests. Having carried out numerous root canal treatment on resin blocks, it appears that this new detection and analysis technique can be used to analyze and anticipate the first signs of damage leading to endodontic file failure. The technological development of such a method, at the level of the engine itself, associated with the act in service procedure, would constitute a revolution in the field of endodontics.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Endodontics and Root Canal Treatments · Drilling and Well Engineering · Dental Radiography and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. Comparison of the cleaning capacity of Mtwo and Pro Taper rotary systems and manual instruments in primary teeth10.4103/1735-3327.95227 ↗
2. Shaping ability of superelastic and controlled memory nickel-titanium file systems: an in vitro study10.1155/2018/6050234 ↗
3. Validated finite element analyses of WaveOne Endodontic Instruments: a comparison between M-Wire and NiTi alloys10.1111/iej.12333 ↗
4. Comparative study of different novel nickel-titanium rotary systems for root canal preparation in severely curved root canals10.1016/j.joen.2013.10.010 ↗
5. A comparison of three rotary systems and hand instrumentation technique for the elimination of Enterococcus faecalis from the root canal10.1111/j.1747-4477.2010.00239.x ↗
6. A comparison of torque required to fracture rotary files with tips bound in simulated curved canal10.1097/01.don.0000148867.30520.9e ↗
7. 2008
8. Review on structural fatigue of NiTi shape memory alloys: pure mechanical and thermo-mechanical ones10.1016/j.taml.2015.11.004 ↗
9. Effects of root canal curvature and mechanical properties of nickel-titanium files on torque generation10.1016/j.joen.2021.06.019 ↗
10. Etude de la fatigue d’instruments endodontiques en alliage à mémoire de forme du type NiTi (Thèse de doctorat)
11. A new approach for detection of wear mechanisms and determination of tool life in turning using acoustic emission10.1016/j.triboint.2015.07.024 ↗
12. Finite element analysis of the mechanical behaviors of endodontic nickel–titanium rotary files: a review10.4186/ej.2023.27.8.29 ↗
13. Quasi-3D dynamic photoelastic analysis of stress distribution during preparation of simulated canals with 13 mechanical preparation systems10.1111/iej.13961 ↗
14. Suppression of acoustic emission during superelastic tensile cycling of polycrystalline ${\mathrm{Ni}}50.4{\mathrm{Ti}}_{49.6
15. Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use10.1097/01.DON.0000129963.42882.C9 ↗
16. Rotary NiTi instrument fracture and its consequences10.1016/j.joen.2006.06.008 ↗
17. Biomedical applications of shape memory alloys10.1155/2011/501483 ↗
18. Fracture of endodontic instruments - Part 1: literature review on factors that influence instrument breakage10.17159/2519-0105/2020/v75no10a4 ↗
19. PMMA (Polimetilmetacrilato) [WWW Document], n.d. URL https://www.plasticfinder.it/en/pmma/polimetilmetacrilato (accessed 6.13.24).
20. Ramesh · 2021
21. Computerized generation and finite element stress analysis of endodontic rotary files10.3390/app11104329 ↗
22. Defects in rotary nickel-titanium files after clinical use10.1097/00004770-200003000-00008 ↗
23. Analysis of torque and force with differently tapered rotary endodontic instruments in vitro10.1097/01.don.0000137634.20499.1d ↗
24. The impact of instrument fracture on outcome of endodontic treatment10.1097/01.don.0000164127.62864.7c ↗
25. Nickel-titanium rotary file systems: what's new?
26. Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: an experimental study10.1097/00004770-200311000-00017 ↗
27. Finite element and experimental structural analysis of endodontic rotary file made of Cu-based single crystal SMA considering a micromechanical behavior model
28. Correlation between acoustic emission detection and microstructural characterization for damage evolution10.1016/j.engfracmech.2020.106967 ↗
29. Mechanisms of instrument failure
30. New thermomechanically treated NiTi alloys – a review10.1111/iej.12924 ↗