Accurate measurement of a bone surrogate flexural rigidity in three- and four-point bending

Mahsa Zojaji, Baixuan Yang, Caitlyn J. Collins, Thomas D. Crenshaw, Heidi-Lynn Ploeg

Abstract

The mechanical assessment of long bones through bending is an established preclinical approach to evaluate the effectiveness of treatments for osteoporosis and fractures. Three- and four-point bending (3PB and 4PB) tests are the most common methods for mechanical characterization of long bones with Euler-Bernoulli (EB) theory to calculate of bone flexural rigidity (EI). Previous studies demonstrated that EB theory underestimates the EI of long bones due to its reliance on assumptions that are not entirely applicable to long bones. Therefore, the current study aimed to evaluate the factors that affect the percent error (PE) and bias stemming from the omission of contact and shear deflections in the EI estimation using mechanical testing and finite element analysis (FEA). The true EI of a porcine bone surrogate was used to quantify the percent error and bias of EI estimations from three deflection measurement methods and FEA, in 3PB and 4PB. The analysis confirmed that bending was the main component of total deflection, but only contributed to approximately 50 % and 65 % of the total deflection in 3PB and 4PB, respectively. The combined shear and indentation deflections accounted for the remainder of the total deflection. The FEA aligned with 3PB and 4PB tests with less than 10 % deviation. Underestimation of EI was largest with deflection measurements taken from the machine crosshead (PE 74 % in 3PB and 71 % in 4PB). However, these underestimations improved notably when indentation and shear deflections were considered (PE 42 % in 3PB and 39 % in 4PB). The deflection measurements from extensometer and digital image correlation (DIC) underestimated the EI by 66 % and 71 % in 3PB, and 57 % and 59 % in 4PB. When corrected for shear and indentation deflections, the 3PB PE reduced to 16 % and 14 %, respectively. In 4PB, PE reduced to, 10 % and 7 %, respectively, demonstrating the advantage of the 4PB test configuration over 3PB. The bias resulting from shear deflection was not consistent across deflection measurement methods; and therefore, cannot be generalized with a constant bias correction. The current study highlighted that a slight error in deflection measurement can lead to a significant inaccuracy in EI measurements. This sensitivity comes from the hyperbolic relationship between EI and deflection which not only depends on the ratio of support span to diameter of the specimen but also the test configuration and the ratio of the elastic to shear modulus of specimen. In other words, the PE from neglecting shear effects increases as the specimen EI increases. Accuracy with less than 10 % PE in EI estimations can be achieved by: 1. taking deflection measurements with extensometers, DIC, or FEA; 2. testing in 4PB instead of 3PB; and, 3. correcting for indentation and shear deflections.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Metal Forming Simulation Techniques · Fatigue and fracture mechanics · Metallurgy and Material Forming

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (45)

Show source-provided references
1. Accuracy of beam theory for estimating bone tissue modulus and yield stress from 3-point bending tests on rat femora10.1016/j.jbiomech.2020.109654 ↗
2. ASTM standard d790-17 , standard test methods for flexural properties of unreinforced and reinforced plastics and electrical insulating materials
3. Mechanical characterization of bone: state of the art in experimental approaches-what types of experiments do people do and how does one interpret the results?10.1007/s11914-018-0454-8 ↗
4. Influence of bone microstructure on the mechanical properties of skull cortical bone – a combined experimental and computational approach10.1016/j.jmbbm.2016.09.041 ↗
5. Wear behaviour of acetal gear pairs10.1016/0043-1648(93)90282-Q ↗
6. Growing C57Bl/6 mice increase whole bone mechanical properties by increasing geometric and material properties10.1359/jbmr.1999.14.12.2159 ↗
7. Saint-Venant’s principle and end effects in anisotropic elasticity10.1115/1.3424095 ↗
8. Design of a surrogate for evaluation of methods to predict bone bending stiffness10.1016/j.jmbbm.2018.08.046 ↗
9. Design of a surrogate for evaluation of methods to predict bone bending stiffness10.1016/j.jmbbm.2018.08.046 ↗
10. Evaluation of experimental, analytical, and computational methods to determine long-bone bending stiffness10.1016/j.jmbbm.2020.104253 ↗
11. Cowin · 2001
12. Skeletal development and repair
13. Four-point bending testing for mechanical assessment of mouse bone structural properties10.1007/978-1-0716-1028-2_12 ↗
14. Using three-point bending to evaluate tibia bone strength in ovariectomized young mice10.1007/s10867-016-9439-y ↗
15. Osteoporosis: the increasing role of the orthopaedist
16. On the Timoshenko theory of transverse beam vibrations10.1090/qam/62620 ↗
17. Methods for assessing bone quality: a review10.1007/s11999-010-1702-0 ↗
18. Shear and torsion correction factors of Timoshenko beam model for generic cross sections
19. Gere · 2000
20. Understanding bland altman analysis10.11613/BM.2015.015 ↗
21. The Odocoileus virginianus femur: mechanical behavior and morphology10.1371/journal.pone.0146611 ↗
22. Epidemiology of osteoporosis10.1016/j.beem.2008.06.001 ↗
23. The friction and wear of polymers in non-conformal contacts10.1016/S0043-1648(96)07270-5 ↗
24. James · 1993
25. Biomechanical properties of bone in a mouse model of Rett syndrome10.1016/j.bone.2014.10.008 ↗
26. Assessment of bone microstructure by micro CT in C57BL/6J mice for sex-specific differentiation10.3390/ijms232314585 ↗
27. Improving the estimate of the effective elastic modulus derived from three-point bending tests of long bones10.1007/s10439-014-1027-3 ↗
28. Three-point bending of rat femur in the mediolateral direction: introduction and validation of a novel biomechanical testing protocol10.1359/jbmr.060511 ↗
29. Variability and anisotropy of mechanical behavior of cortical bone in tension and compression10.1016/j.jmbbm.2013.02.021 ↗
30. Bone mechanical properties in healthy and diseased states10.1146/annurev-bioeng-062117-121139 ↗
31. Bone mechanical properties in healthy and diseased states10.1146/annurev-bioeng-062117-121139 ↗
32. Influence of bone defect position and span in 3-point bending tests: experimental and finite element analysis
33. Puttock · 1969
34. Genetic relationships between obesity and osteoporosis in LGXSM recombinant inbred mice10.1017/S0016672308009798 ↗
35. The worldwide problem of osteoporosis: insights afforded by epidemiology10.1016/8756-3282(95)00258-4 ↗
36. Cortical and trabecular bone microarchitecture as an independent predictor of incident fracture risk in older women and men in the Bone Microarchitecture International Consortium (BoMIC): a prospective study10.1016/S2213-8587(18)30308-5 ↗
37. A comparison of mechanical properties derived from multiple skeletal sites in mice10.1016/j.jbiomech.2004.04.020 ↗
38. Comparison between different methods for biomechanical assessment of ex vivo fracture callus stiffness in small animal bone healing studies10.1371/journal.pone.0119603 ↗
39. Morphological analysis of the proximal femur using quantitative computed tomography10.1007/s00264-006-0182-z ↗
40. Timoshenko · 1970
41. Basic biomechanical measurements of bone: a tutorial10.1016/8756-3282(93)90081-K ↗
42. Tissue modulus calculated from beam theory is biased by bone size and geometry: implications for the use of three-point bending tests to determine bone tissue modulus10.1016/j.bone.2008.06.008 ↗
43. Major source of error when calculating bone mechanical properties10.1002/jbmr.2304 ↗
44. Young · 2002 · vol. 7
45. Combining specimen-specific finite-element models and optimization in cortical-bone material characterization improves prediction accuracy in three-point bending tests10.1016/j.jbiomech.2018.05.042 ↗