Anisotropic wear behavior of meniscus: Influence of cross-shear and loading magnitude
Source abstract
Abstract
The repetitive wear-and-tear of knee menisci contributes to chronic knee pain and disability, yet the mechanical factors driving this degenerative process are poorly understood. Here we characterize the effect of motion type and loading magnitude on the anisotropic wear behavior of bovine meniscus. Custom pin-on-plate systems applied 60,000 cycles of unidirectional motion or multidirectional (cross-shear) motion by translating a sectioned "plate" of meniscus under a fixed cartilage "pin" that was loaded to generate physiological stress conditions (0.5, 1.0, 1.5 MPa). Pin motion was applied either longitudinal or transverse to the circumferential fibers of the meniscal tissue. We measured the effect of wear testing on meniscal volume loss, compressive mechanical properties, fiber fraying, and superficial layer thickness. A three-fold increase in loading magnitude resulted in a 36% increase in volume loss and a significant increase in fiber fraying. Multidirectional motion resulted in 31% greater volume loss than unidirectional motion, however, this change was not significant. Transverse specimens exhibited 1.8x greater volume loss than longitudinal specimens. Multiple regression revealed that meniscal tissue was more resistant to wear when it had higher initial tissue stiffness and greater initial stress relaxation. For the first time, this study has demonstrated that the meniscus exhibits anisotropic wear behavior that is governed by the compressive loading magnitude. This study provides foundational data and mechanistic insights on the wear behavior of the knee meniscus.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Adhesion, Friction, and Surface Interactions · Gear and Bearing Dynamics Analysis · Mechanical stress and fatigue analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (85)
Show source-provided references
1. A comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements10.1016/j.jmbbm.2017.11.022 ↗
2. Regional and fiber orientation dependent shear properties and anisotropy of bovine meniscus10.1016/j.jmbbm.2011.06.022 ↗
3. In-vitro measurement of static pressure distribution in synovial joints--Part I: tibial surface of the knee10.1115/1.3138409 ↗
4. Quantitative 3D magnetic resonance elastography: comparison with dynamic mechanical analysis10.1002/mrm.26207 ↗
5. The role of interstitial fluid pressurization in articular cartilage lubrication10.1016/j.jbiomech.2009.04.040 ↗
6. Functional characterization of normal and degraded bovine meniscus: rate-dependent indentation and friction studies10.1016/j.bone.2012.03.009 ↗
7. Bayer · 2004
8. In vitro method to quantify and visualize mechanical wear in human meniscus subjected to joint loading10.1016/j.jmbbm.2022.105338 ↗
9. Guidelines for accurate multi-temporal model registration of 3D scanned objects10.3390/jimaging9020043 ↗
10. A procedure for slicing and characterizing soft heterogeneous and irregular-shaped tissue10.1016/j.matpr.2020.07.624 ↗
11. The interplay of biomechanical and biological changes following meniscus injury10.1007/s11926-022-01093-3 ↗
12. The importance of multidirectional motion on the wear of polyethylene10.1243/PIME_PROC_1996_210_408_02 ↗
13. Investigation of the frictional response of osteoarthritic human tibiofemoral joints and the potential beneficial tribological effect of healthy synovial fluid10.1016/j.joca.2009.03.020 ↗
14. Compressive moduli of the human medial meniscus in the axial and radial directions at equilibrium and at a physiological strain rate10.1002/jor.20573 ↗
15. Effect of rotational and sliding motions on friction and degeneration of articular cartilage under dry and wet friction10.1016/S1672-6529(14)60137-2 ↗
16. Anisotropy in the viscoelastic response of knee Meniscus cartilage
17. Collagenous fibril texture of the discoid lateral Meniscus10.1016/j.arthro.2007.01.018 ↗
18. Characterization of site-specific biomechanical properties of human meniscus—Importance of collagen and fluid on mechanical nonlinearities10.1016/j.jbiomech.2015.01.048 ↗
19. Poisson's ratio of bovine meniscus determined combining unconfined and confined compression10.1016/j.jbiomech.2018.07.001 ↗
20. Immature bovine cartilage wear by fatigue failure and delamination10.1016/j.jbiomech.2020.109852 ↗
21. Knee joint forces: prediction, measurement, and significance10.1177/0954411911433372 ↗
22. Structural properties of the meniscal roots10.1177/0363546514531730 ↗
23. Quantification of in vitro wear of a synthetic meniscus implant using gravimetric and micro-CT measurements10.1016/j.jmbbm.2015.05.017 ↗
24. Incidental meniscal findings on knee MRI in middle-aged and elderly persons10.1056/NEJMoa0800777 ↗
25. Multiscale mechanical evaluation of human supraspinatus tendon under shear loading after glycosaminoglycan reduction10.1115/1.4036602 ↗
26. Effects of degeneration on the compressive and tensile properties of human meniscus10.1016/j.jbiomech.2015.02.042 ↗
27. The basic science of human knee menisci: structure, composition, and function10.1177/1941738111429419 ↗
28. Frictional properties of the meniscus improve after scaffold-augmented repair of partial meniscectomy: a pilot study10.1007/s11999-011-1854-6 ↗
29. Meniscus injuries: where do we stand?
30. Tribological role of synovial fluid compositions on artificial joints — a systematic review of the last 10 years10.1002/ls.1266 ↗
31. Dynamic contact mechanics on the tibial plateau of the human knee during activities of daily living10.1016/j.jbiomech.2013.11.003 ↗
32. Quantifying wear depth in hip prostheses using a 3D optical scanner10.1016/j.wear.2017.10.008 ↗
33. Anisotropic properties of articular cartilage in an accelerated in vitro wear test10.1016/j.jmbbm.2020.103834 ↗
34. Is collagen fiber damage the cause of early softening in articular cartilage?10.1016/j.joca.2012.09.002 ↗
35. Degenerative meniscus: pathogenesis, diagnosis, and treatment options10.5312/wjo.v5.i5.597 ↗
36. Identification of pathways and genes associated with meniscus degeneration using bioinformatics analyses
37. 2014
38. Interspecies variation of compressive biomechanical properties of the meniscus10.1002/jbm.820290706 ↗
39. Tribological properties of PVA/PVP blend hydrogels against articular cartilage10.1016/j.jmbbm.2017.10.027 ↗
40. Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE10.1016/j.jbiomech.2007.09.005 ↗
41. Quantitative three-dimensional collagen orientation analysis of human meniscus posterior horn in health and osteoarthritis using micro-computed tomography10.1016/j.joca.2021.01.009 ↗
42. Violating the normality assumption may be the lesser of two evils10.3758/s13428-021-01587-5 ↗
43. Protease inhibitors: current status and future prospects10.1021/jm990412m ↗
44. Constitutive equations for analyzing stress relaxation and creep of viscoelastic materials based on standard linear solid model derived with finite loading rate10.3390/polym14102124 ↗
45. The tribology of cartilage: mechanisms, experimental techniques, and relevance to translational tissue engineering10.1016/j.clinbiomech.2019.10.016 ↗
46. The effect of contact stress on cartilage friction, deformation and wear10.1177/2041303310392626 ↗
47. The importance of the normality assumption in large public health data sets10.1146/annurev.publhealth.23.100901.140546 ↗
48. An in vitro study of cartilage–meniscus tribology to understand the changes caused by a meniscus implant10.1016/j.colsurfb.2017.04.034 ↗
49. Influence of the meniscus on friction and degradation of cartilage in the natural knee joint10.1016/j.joca.2009.02.012 ↗
50. Energy expended and knee joint load accumulated when walking, running, or standing for the same amount of time10.1016/j.gaitpost.2014.10.009 ↗
51. Tribological and material properties for cartilage of and throughout the bovine stifle: support for the altered joint kinematics hypothesis of osteoarthritis10.1016/j.joca.2014.09.021 ↗
52. A validated software application to measure fiber organization in soft tissue10.1007/s10237-016-0776-3 ↗
53. In vivo knee loading characteristics during activities of daily living as measured by an instrumented total knee replacement10.1002/jor.20655 ↗
54. Regional dependency of bovine meniscus biomechanics on the internal structure and glycosaminoglycan content10.1016/j.jmbbm.2019.02.020 ↗
55. Effect size, confidence interval and statistical significance: a practical guide for biologists10.1111/j.1469-185X.2007.00027.x ↗
56. Effects of inflammation on multiscale biomechanical properties of cartilaginous cells and tissues10.1021/acsbiomaterials.6b00671 ↗
57. Enhanced cellular infiltration of human adipose-derived stem cells in allograft menisci using a needle-punch method10.1186/s13018-016-0467-x ↗
58. A multi-directional in vitro investigation into friction, damage and wear of innovative chondroplasty materials against articular cartilage10.1016/j.clinbiomech.2007.03.008 ↗
59. Wear and damage of articular cartilage with friction against orthopedic implant materials10.1016/j.jbiomech.2015.04.008 ↗
60. Macroscopic and histopathologic analysis of human knee menisci in aging and osteoarthritis10.1016/j.joca.2011.05.008 ↗
61. Biomechanical and cellular segmental characterization of human meniscus: building the basis for tissue engineering therapies10.1016/j.joca.2014.07.001 ↗
62. Immature bovine cartilage wear is due to fatigue failure from repetitive compressive forces and not reciprocating frictional forces10.1016/j.joca.2023.08.008 ↗
63. Osteoarthritis cartilage histopathology: grading and staging10.1016/j.joca.2005.07.014 ↗
64. Material properties of the normal medial bovine meniscus10.1002/jor.1100070602 ↗
65. Collagen orientation probed by polarized Raman spectra can serve as differential diagnosis indicator between different grades of meniscus degeneration10.1038/s41598-021-99569-2 ↗
66. Meniscal measurements of T1ρ and T2 at MR imaging in healthy subjects and patients with osteoarthritis10.1148/radiol.2492071870 ↗
67. Wear testing of moderate activities of daily living using in vivo measured knee joint loading. Zadpoor AA, ed10.1371/journal.pone.0123155 ↗
68. Robustness of linear mixed-effects models to violations of distributional assumptions10.1111/2041-210X.13434 ↗
69. The biomechanical properties of human menisci: a systematic review10.1016/j.actbio.2023.12.010 ↗
70. Definition and evaluation of testing scenarios for knee wear simulation under conditions of highly demanding daily activities10.1016/j.medengphy.2012.07.003 ↗
71. Osteoarthritis-related degeneration alters the biomechanical properties of human Menisci before the articular cartilage10.3389/fbioe.2021.659989 ↗
72. Detecting multicollinearity in regression analysis10.12691/ajams-8-2-1 ↗
73. Bovine Meniscus middle zone tissue: measurement of collagen fibril behavior during compression10.2147/IJN.S261298 ↗
74. Risk factors for meniscal tears: a systematic review including meta-analysis10.2519/jospt.2013.4295 ↗
75. Intraspecies and interspecies comparison of the compressive properties of the medial meniscus10.1114/B:ABME.0000049040.70767.5c ↗
76. Age-related changes in the knee meniscus10.1016/j.knee.2017.08.001 ↗
77. Quantification of the effect of cross-path motion on the wear rate of ultra-high molecular weight polyethylene10.1016/S0043-1648(03)00357-0 ↗
78. Cartilage-on-cartilage cyclic loading induces mechanical and structural damage10.1016/j.jmbbm.2019.06.023 ↗
79. Applying ASTM standards to tensile tests of musculoskeletal soft tissue: methods to reduce grip failures and promote reproducibility10.1115/1.4048646 ↗
80. Effect of superficial collagen fibre orientation of articular cartilage on its anisotropic tribological behaviour10.26599/FRICT.2025.9440935 ↗
81. Friction properties of a new silk fibroin scaffold for meniscal replacement10.1016/j.triboint.2017.01.038 ↗
82. Degeneration alters the biomechanical properties and structural composition of lateral human menisci10.1016/j.joca.2020.07.004 ↗
83. Traumatic meniscal tears are associated with meniscal degeneration10.1177/0363546520934766 ↗
84. The effects of body-borne loads and cadence manipulation on patellofemoral and tibiofemoral joint kinetics during running10.1016/j.jbiomech.2016.10.043 ↗
85. Mechanical properties of graphene foam and graphene foam—tissue composites10.1002/adem.201800166 ↗