journal article·2026-02

A virtual model for the osteosynthesis fixation strength analysis of cancellous screws considering the insertion effect in sawbones with experimental validation

James Wu, Xuan Hu, David Benoit, Franck Le Navéaux, Julien Clin, Shaofan Li, Reno Genest, Ram Gopisetti, Bo Ren

Publisher page

Abstract

Although the finite element method (FEM) is a valuable computational tool for analyzing factors that influence bone-screw fixation strength in osteosynthesis, it faces challenges in capturing the effects of screw insertion prior to pullout simulation due to mesh distortion and element erosion. To address these limitations, this study introduces an orthopedic computational model based on the Smoothed Particle Galerkin (SPG) method, offering an enhanced approach for simulating bone-screw interactions. The Smoothed Particle Galerkin (SPG) method is an advanced mesh-free numerical technique capable of simulating large deformations and material removal while avoiding common mesh-related issues in FEM. In this study, the SPG method is used to model the Sawbones material during screw insertion and pullout. A bond-failure model is incorporated into the SPG framework to represent material removal, employing two failure criteria: the critical effective shear strain and the critical effective plastic strain. This modeling approach allows for accurate reproduction of thread formation in the bone during screw insertion, capturing the appropriate contact geometry and residual stress conditions for subsequent pullout simulations. To validate the accuracy of the proposed simulation model, experimental tests were performed using Sawbones specimens composed of grade 15 PCF polyurethane foam, serving as an analog for human cancellous bone. The nonlinear material properties of the Sawbones were characterized following ASTM D1621 for compression and ASTM D1623 for tension. Parameters of the bond-failure model were calibrated through a combined screw insertion and pullout simulation using a non-fluted screw with a pilot hole. For the predictive analysis, three test cases were modeled, each combining different pilot-hole sizes and screw types, with and without cutting flutes. The proposed simulation model successfully reproduces thread formation, a feature that is difficult to capture using conventional FEM approaches. The results demonstrate that screw insertion induces residual stress, which strongly affects the pullout force. In addition, both pilot-hole size and screw design are shown to significantly influence residual stress and pullout performance. Comparison of pullout forces between experiments and simulations across three prediction cases, showing average errors of +4.0 %, -11.8 %, and -6.0 %, indicates that the proposed model is a promising tool for analyzing bone-screw fixation strength while accounting for the screw insertion effect, a capability not available in existing simulation frameworks.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone health and osteoporosis research · Orthopedic Surgery and Rehabilitation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (54)

Show source-provided references
1. Pullout strength of cancellous screws in human femoral heads depends on applied insertion torque, trabecular bone microarchitecture and areal bone mineral density10.1016/j.jmbbm.2014.09.009 ↗
2. Screw insertion torque as parameter to judge the fixation. Assessment of torque and pullout strength in different bone densities and screw-pitches10.1016/j.clinbiomech.2019.12.004 ↗
3. Torque and pullout analysis of six currently available self-tapping and “emergency” screws10.1016/S0278-2391(10)80389-1 ↗
4. Meshfree methods: progress made after 20 years
5. The biomechanics of pedicle screw-based instrumentation
6. Biomechanical analysis of the placement of fixation lag screw in different intertrochanteric hip fracture angles10.1049/bsbt.2018.0035 ↗
7. Correlations between screw hole preparation, torque of insertion, and pullout strength for spinal screws10.1097/00002517-199407020-00007 ↗
8. A biomedical evaluation of orthopaedic implants for hip fractures by finite element analysis and in-vitro tests10.1243/09544119JEIM799 ↗
9. Biomechanics of locked plates and screws10.1097/00005131-200409000-00003 ↗
10. Homogenized finite element models can accurately predict screw pullout in continuum materials, but not in porous materials10.1016/j.cmpb.2021.105966 ↗
11. Numerical analysis of temperature screwing moment and thrust force using finite element method in bone screw process10.1142/S0219519417500166 ↗
12. Alignment of pedicle screws with pilot holes: can tapping improve screw trajectory in thoracic spines?10.1007/s00586-009-1063-0 ↗
13. A peridynamics-SPH modeling and simulation of blast fragmentation of soil under buried explosive loads10.1016/j.cma.2017.01.026 ↗
14. Screw tightness and stripping rates vary between biomechanical researchers and practicing orthopedic surgeons10.1186/s13018-021-02800-z ↗
15. Fine thread versus coarse thread: a comparison of the maximum holding power10.1016/S0020-1383(01)00168-1 ↗
16. Does the location of the cutting flute of self-tapping screws in bone substrate affect the removal torque?10.4236/ojo.2015.51001 ↗
17. Rotary ultrasonic bone drilling: improved pullout strength and reduced damage10.1016/j.medengphy.2016.11.004 ↗
18. Prediction of stress shielding around an orthopedic screw: using stress and strain energy density as mechanical stimuli10.1016/j.compbiomed.2013.07.032 ↗
19. Biomechanical comparison of fixation among various pedicle screw geometries: effects of screw outer/inner projection shape and thread profile10.3390/app11219901 ↗
20. Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses10.1016/j.orthres.2004.11.002 ↗
21. Biomechanical effects of internal fixation with self-lock compression anti-rotation blade for Pauwels type III femoral neck fractures: a comparative finite element analysis10.1186/s12891-023-06386-x ↗
22. Full-field characterization of mechanical behavior of polyurethane foams10.1016/j.ijsolstr.2007.03.018 ↗
23. Biomechanical investigation of bone screw head design for extracting stripped screw heads: integration of mechanical tests and finite element analyses10.3390/ma16155470 ↗
24. Effect of pilot hole diameter and tapping on insertion torque and axial pullout strength of 4.0-mm cancellous bone screws10.2460/ajvr.72.12.1660 ↗
25. Li · 2004
26. Finite element analysis of different screw constructs in the treatment of unstable femoral neck fractures10.1016/j.injury.2020.02.075 ↗
27. Cutting of blood clots – experimental and smoothed particle Galerkin modeling10.1016/j.cirp.2019.04.025 ↗
28. Numerical prediction of residual deformation and failure for powder bed fusion additive manufacturing of metal parts10.1017/jmech.2020.30 ↗
29. Stress state dependent damage modeling of self-pierce riveting process simulation using GISSMO damage model
30. A momentum-consistent stabilization algorithm for Lagrangian particle methods in the thermo-mechanical friction drilling analysis10.1007/s00466-019-01673-8 ↗
31. The effect of screw insertion angle and thread type on the pullout strength of bone screws in normal and osteoporotic cancellous bone models10.1016/j.medengphy.2010.05.005 ↗
32. Local heat generation during screw insertion into diaphysical bone: a biomechanical study on different conditions (e.g. screw type, material, mode of insertion)10.1186/s12891-021-04723-6 ↗
33. Mechanical performance of thoracolumbosacral pedicle screw systems: an analysis of data submitted to food and drug administration10.1016/j.jbiomech.2021.110551 ↗
34. A comparison of pullout strength for pedicel screws of different designs: a study using tapped and untapped pilot holes10.1097/01.brs.0000244658.35865.59 ↗
35. The emerging utility of composite bone models in biomechanical studies of the hand and upper extremity10.1016/j.jhsa.2012.12.005 ↗
36. A peridynamic failure analysis of fiber-reinforced composite laminates using finite element discontinuous Galerkin approximations10.1007/s10704-018-0317-4 ↗
37. Finite element analysis of cannulated screws as prophylactic intervention of hip fractures10.1177/21514593211055890 ↗
38. Screw-related complications after instrumentation of the osteoporotic spine: a systematic literature review with meta-analysis10.1177/2192568218818164 ↗
39. Temperature and force generation in surgical bone drilling10.1063/5.0037543 ↗
40. Effect of pilot hole on biomechanical and in vivo pedicle screw-bone interface10.1007/s00586-013-2810-9 ↗
41. A particle method for history-dependent materials10.1016/0045-7825(94)90112-0 ↗
42. Characterization of three formulations of a synthetic foam as models for a range of human cancellous bone types10.1002/jab.770060207 ↗
43. The biomechanical effect of artificial and human bone density on stopping and stripping torque during screw insertion10.1016/j.jmbbm.2013.03.006 ↗
44. An efficient nesting sub-domain gradient smoothing integration algorithm with quadratic exactness for Galerkin meshfree methods10.1016/j.cma.2015.10.008 ↗
45. A three-dimensional two-level gradient smoothing meshfree method for rainfall-induced landslide simulations10.1007/s11709-018-0467-5 ↗
46. Comparative finite element analysis of three implants fixing stable and unstable sub-trochanteric femoral fractures: proximal femoral nail anti-rotation (PFNA), proximal femoral locking plate (PFLP), and reverse less invasive stabilization system (LISS)
47. Influence of thread design on anchorage of pedicle screws in cancellous bone: an experimental and analytical analysis10.1038/s41598-022-11824-2 ↗
48. Individualized prediction of pedicle screw fixation strength with a finite element model10.1080/10255842.2019.1709173 ↗
49. Stripping torque model for bone screws10.1016/j.ifacol.2021.10.296 ↗
50. The momentum-consistent smoothed particle Galerkin (MC-SPG) method for simulating the extreme thread forming in the flow drill screw-driving process10.1007/s40571-019-00235-2 ↗
51. Microdamage of the cortical bone during mini-implant insertion with self-drilling and self-tapping techniques: a randomized controlled trial10.1016/j.ajodo.2011.12.016 ↗
52. Computational evaluation of the axis-blade angle for measurements of implant positions in trochanteric hip fractures: a finite element analysis10.1016/j.compbiomed.2023.106830 ↗
53. Notched K-wire for low thermal damage bone drilling10.1016/j.medengphy.2017.04.001 ↗
54. Mechanical properties of synthetic bones made by synbone: a review10.1115/1.4063123 ↗