journal article·2026-02Open access

Evaluation of a universal talus implant during gait: a combined musculoskeletal and finite element modelling approach

Sami Al Shweiki, Stephen J. Ferguson, Ahmed H. Hafez, Naod T. Mogos, Tao Liu, Marwan El-Rich

Abstract

Universal talus implant has emerged as an innovative solution for talus bone collapse, aiming to retain the clinical benefits of custom total talus replacement while addressing its logistical drawbacks. A subject-specific combined musculoskeletal–finite element (MSK–FE) modeling framework was developed to evaluate two universal talus implant designs during dynamic gait: a purely cobalt chromium (CoCr) implant, and an implant coated with polycarbonate-urethane (PCU), both compared to the native talus. To do so, a MSK simulation of the stance phase of gait was conducted to estimate joint kinematics and joint reaction forces in the ankle complex, with a subsequent dynamic FE simulation performed to assess contact characteristics in terms of contact area and pressure, in cartilages surrounding the talus/implant. The FE model was built directly from the bone geometries of the MSK model to ensure consistency across the study. Results showed that the PCU-coated implant more closely replicated native biomechanics, while the CoCr implant produced consistently higher pressures and smaller contact regions. Normalized RMSE across gait confirmed lower deviation from the native case for the PCU-implant in most joints. These findings highlight the potential of PCU coated implants in improving contact mechanics in articular cartilage as well as the potential of the universal implant topology. This is the first study to dynamically evaluate intra-articular behaviour in all joints surrounding the talus bone during gait, and particularly by analysing the performance of universal talus implants, demonstrating the utility of a MSK-FE approach and offering valuable insights into implant performance under physiological conditions, informing future implant design. • Analysis of contact characteristics in the ankle complex during gait • A combined, subject-specific, musculoskeletal and finite element modelling approach • Evaluation of two universal talus implant designs: metallic and PCU-coated • The metallic implant resulted in highest contact pressures and smallest contact areas • PCU-coated implant performs similarly to the biological talus
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Foot and Ankle Surgery · Diabetic Foot Ulcer Assessment and Management · Lower Extremity Biomechanics and Pathologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Subject specific finite element modelling of the human foot complex during walking: sensitivity analysis of material properties, boundary and loading conditions10.1007/s10237-017-0978-3 ↗
2. Physico-mechanical properties and prosthodontic applications of co-cr dental alloys: a review of the literature10.4047/jap.2014.6.2.138 ↗
3. Intra-articular contact stress distributions at the ankle throughout stance phase-patient-specific finite element analysis as a metric of degeneration propensity10.1007/s10237-006-0025-2 ↗
4. Physical validation of a patient-specific contact finite element model of the ankle10.1016/j.jbiomech.2007.01.024 ↗
5. An extended discrete element method for the estimation of contact pressure at the ankle joint during stance phase10.1177/0954411920905434 ↗
6. Comparison between kinetic and kinetic-kinematic driven knee joint finite element models10.1038/s41598-018-35628-5 ↗
7. Development and implantation of a universal talar prosthesis10.3389/fsurg.2019.00063 ↗
8. Assessment of common hyperelastic constitutive equations for describing normal and osteoarthritic articular cartilage10.1243/09544119JEIM546 ↗
9. Tlem 2.0– a comprehensive musculoskeletal geometry dataset for subject-specific modeling of lower extremity10.1016/j.jbiomech.2014.12.034 ↗
10. Foot arch deformation and plantar fascia loading during running with rearfoot strike and forefoot strike: a dynamic finite element analysis10.1016/j.jbiomech.2018.12.007 ↗
11. Dynamic finite element analyses to compare the influences of customised total talar replacement and total ankle arthroplasty on foot biomechanics during gait
12. Decreased stress shielding with a PEEK femoral total knee prosthesis measured in validated computational models10.1016/j.jbiomech.2021.110270 ↗
13. Tibiofemoral cartilage contact pressures in athletes during landing: a dynamic finite element study10.1115/1.4051231 ↗
14. Treatments for avascular necrosis of the talus: a systematic review10.1177/1938640014521831 ↗
15. Intermediate and long-term outcomes of total ankle arthroplasty and ankle arthrodesis: a systematic review of the literature10.2106/00004623-200709000-00002 ↗
16. Design of a lightweight universal talus implant using topology optimization10.3389/fbioe.2023.1228809 ↗
17. Design of a lightweight universal talus implant using topology optimization10.3389/fbioe.2023.1228809 ↗
18. Ankle joint contact loads and displacement with progressive syndesmotic injury10.1177/1071100715583456 ↗
19. A 24-month follow-up of a custom-made suture-button assembly for syndesmotic injuries of the ankle10.1053/j.jfas.2017.02.010 ↗
20. Three-dimensional geometric analysis of the talus for designing talar prosthetics10.1177/0954411914527741 ↗
21. Ceramic artificial talus as the initial treatment for comminuted talar fractures10.1177/1071100719875723 ↗
22. The evaluation of artificial talus implant on ankle joint contact characteristics: a f inite element study based on four subjects10.1007/s11517-022-02527-x ↗
23. Polycarbonate-urethane coating can significantly improve talus implant contact characteristics10.1016/j.jmbbm.2021.104936 ↗
24. Development and validation of a novel ankle joint musculoskeletal model10.1007/s11517-023-03010-x ↗
25. Effects of implant orientation and implant material on tibia bone strain, implant–bone micromotion, contact pressure, and wear depth due to total ankle replacement10.1177/0954411918823811 ↗
26. Implementation of a gait cycle loading into healthy and meniscectomised knee joint models with fibril-reinforced articular cartilage10.1080/10255842.2013.783575 ↗
27. Effects of radial tears and partial meniscectomy of lateral meniscus on the knee joint mechanics during the stance phase of the gait cycle—a 3d finite element study10.1002/jor.22358 ↗
28. The glasgow–maastricht foot model, evaluation of a 26 segment kinematic model of the foot10.1186/s13047-016-0152-7 ↗
29. Factors affecting the outcomes of tibiotalocalcaneal fusion10.1302/0301-620X.102B3.BJJ-2019-1325.R1 ↗
30. Mechanical properties of normal and osteoarthritic human articular cartilage10.1016/j.jmbbm.2016.01.015 ↗
31. Cartilage thickness of the talar dome10.1016/j.arthro.2004.12.005 ↗
32. Clinically useful finite element models of the natural ankle– a review10.1016/j.clinbiomech.2023.106006 ↗
33. Custom-made alumina ceramic total talar prosthesis for idiopathic aseptic necrosis of the talus: report of two cases
34. Custom 3d-printed total talar prostheses restore normal joint anatomy throughout the hindfoot10.1177/1938640018762567 ↗
35. Geometric analysis of the talus and development of a generic talar prosthetic10.1016/j.fas.2016.12.002 ↗
36. Analysis of a generic talar prosthetic with a biological talus: a cadaver study10.1016/j.jor.2018.01.015 ↗
37. Effect of bone inhomogeneity on tibiofemoral contact mechanics during physiological loading10.1016/j.jbiomech.2016.02.033 ↗
38. Are subject-specific musculoskeletal models robust to the uncertainties in parameter identification?10.1371/journal.pone.0112625 ↗
39. Pressure distribution in the ankle and subtalar joint with routine and oversized foot orthoses10.1177/1071100718770659 ↗