Stress distribution and axial force under different filing parameters during root canal preparation: An in vitro FEA and experimental study
Source abstract
Abstract
Background Inappropriate rotational and feed speed of the rotary nickel-titanium (Ni-Ti) file can cause damage to the root canal wall. Consequently, it is essential to examine the relationships among filing parameters, file stress, and axial force to establish a dependable foundation for the selection of parameters. Method A 3D reconstruction of the tooth is executed utilizing CBCT images. The reaming rate of root canal filling is established at 30 % to examine the correlation between Root Canal Preparation (RCP) parameters and damage under critical situations. Utilizing the elastic-plastic model and the Johnson-Cook intrinsic model, the explicit dynamics method of ABAQUS software is employed to simulate the contact stress and axial force at varying feed speeds (1-8 mm/s) and rotational speeds (150-800 rpm). A robotic arm-based filing experimental platform is developed to conduct bionic experiments, which examine the variation of axial filing force with different parameters, and these results are compared with simulation outcomes. Results Increased rotational speed and decreased feed speed of the root canal file can diminish the stress and strain on the root canal. The trends and magnitudes of axial force derived from simulation and experiment at varying speeds are comparable (deviation factor = 0.15 %-25.82 %). A rotational speed higher than 350 rpm and a feed speed lower than 6 mm/s are more conducive to stable and safe filing, and the maximum axial force and the maximum stress exhibit a trend analogous. Conclusion This study provides a basis for the selection of filing parameters for manual and robot-assisted RCP, thereby improving the safety of clinical preparation.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Endodontics and Root Canal Treatments · Dental materials and restorations · Surgical Sutures and Adhesives
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. A review of cutting mechanics and modeling techniques for biologicalmaterials
2. Effect of flushing temperature on preparation ability of rotary nickel-titanium files
3. Chen · 2008
4. Bone stress and damage distributions during dental implant insertion: a novel dynamic FEM analysis10.1080/10255842.2021.2012765 ↗
5. Comparative study of torsional and bending stress in NiTi, graphene, and GUM metal endodontic files by finite element analysis
6. Endodontic treatment in artificial deciduous teeth by manual and mechanical instrumentation: a pilot study10.5005/jp-journals-10005-1566 ↗
7. Simulation analysis of stress distribution of NRT FILES in curved root canals. Chin
8. Potential relationship between design of nickel-titanium rotary instruments and vertical root fracture10.1016/j.joen.2010.02.010 ↗
9. In vitro comparative study of the influence of instrument taper on the fracture resistance of endodontically treated teeth: an integrative approach-based analysis10.1016/j.joen.2018.05.007 ↗
10. A new method to measure the mechanical properties of rotary endodontic Ni-Ti files: measurement of 6-axis force/torque and automatic root canal preparation10.4012/dmj.2024-082 ↗
11. Drilling in cortical bone: a finite element model and experimental investigations10.1016/j.jmbbm.2014.10.017 ↗
12. Assessment of real-time operative torque during nickel-titanium instrumentation with different lubricants10.3390/app10186201 ↗
13. Evaluation of forces generated on three different rotary file systems in apical third of root canal using finite element analysis
14. Simulated evaluation of tooth fracture resistance during instrumentation with single-and multi-file rotary system. Iran
15. Mechanical behavior of M-Wire and conventional NiTi wire used to manufacture rotary endodontic instruments10.1016/j.dental.2013.10.004 ↗
16. Finite element stress analysis after simulated canal preparation using two different methods: an in vitro study10.4103/jicdro.jicdro_31_23 ↗
17. Optimization of process parameters for drilled hole quality characteristics during cortical bone drilling using taguchi method10.1016/j.jmbbm.2016.05.015 ↗
18. Investigation, sensitivity analysis, and multi-objective optimization of effective parameters on temperature and force in robotic drilling cortical bone10.1177/0954411917726098 ↗
19. Force and vibration analysis in biomechanical preparation of root canals using reciprocating endodontic file system: in vitro study10.1177/09544119211044236 ↗
20. Dynamic force identification in peripheral milling based on cgls using filtered acceleration signals and averaged transfer functions10.1115/1.4043362 ↗
21. Improvement and analysis of mechanistic modeling of root canal preparation by a computer-based method10.1016/j.cmpb.2022.106636 ↗
22. The relationship of root canal enlargement to finger-spreader induced vertical root fracture10.1016/S0099-2399(97)80316-0 ↗
23. Comparison of mandibular premolars and canines with respect to their resistance to vertical root fracture10.1016/j.jdent.2003.12.002 ↗
24. Accuracy evaluation of dental CBCT and scanned model registration method based on pulp horn mapping surface: an in vitro proof-of-concept10.1186/s12903-024-04565-3 ↗
25. Root canal preparation robot based on guiding strategy for safe remote therapy: system design and feasibility study (2023)10.1109/TMECH.2024.3383215 ↗
26. Biomechanical behavior of customized splint for the patient with temporomandibular disorders: a three-dimensional finite element analysis10.1016/j.bbe.2023.12.007 ↗