journal article·2026-06

Fatigue performance of additively manufactured porous titanium for orthopaedic applications

Jonah Leinwand, Rene Lam, Sagar Patel, Martine McGregor, Stewart McLachlin, Mihaela Vlasea

Publisher page

Abstract

Lattice structures are increasingly being adopted for orthopaedic implant designs; however, questions remain about the long-term strength and risk of fatigue failure of porous titanium (Ti) and Ti-alloy structures. To provide a deeper understanding of this issue, this study conducted a comprehensive review of fatigue performance of latticed Ti/Ti-alloy parts, printed via laser powder bed fusion (PBF-LB), for orthopaedic applications, spanning studies over the past decade. Key lattice parameters were collected, including porosity, pore size, feature thickness, and lattice type, and their corresponding effect on fatigue performance of the end part. This review found that many Ti/Ti-alloy lattice structures can achieve comparable mechanical properties to trabecular bone (E of 0.01-3 GPa, fatigue strength of 0.3-3 MPa) while only one reviewed sample matched both the Young's modulus and fatigue strength of cortical bone (E of 15-20 GPa, fatigue strength 40-60 MPa). This review addresses the gap in having consolidated data describing the effects of various properties of Ti/Ti-alloy lattices on their compressive fatigue strengths, providing guidance on design considerations of such lattice structures for orthopaedic applications. Data provided in this review further highlights the need for continued development of implant latticing strategies and design parameter development to better mimic human cortical bone in orthopaedic implants.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cellular and Composite Structures · Titanium Alloys Microstructure and Properties · Additive Manufacturing Materials and Processes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (100+)

Show source-provided references
1. Titanium-based alloys and composites for orthopedic implants applications: A comprehensive review10.1016/j.matdes.2024.112850 ↗
2. Determining critical surface features affecting fatigue behavior of additively manufactured Ti-6Al-4V10.1016/j.ijfatigue.2025.108956 ↗
3. From microstructural design to surface engineering: A tailored approach for improving fatigue life of additively manufactured meta-biomaterials10.1016/j.actbio.2018.10.043 ↗
4. Effects of build orientation and inclined features on physical, microstructural and mechanical properties of powder bed fusion additively manufactured metallic parts10.1016/j.pmatsci.2024.101357 ↗
5. Laser-inherent porosity defects in additively manufactured Ti–6Al–4V implant: Formation, distribution, and effect on fatigue performance10.1016/j.jmrt.2024.04.225 ↗
6. American Association of Hip and Knee Surgeons · 2018
7. Relationship between unit cell type and porosity and the fatigue behavior of selective laser melted meta-biomaterials10.1016/j.jmbbm.2014.12.015 ↗
8. An overview of modern metal additive manufacturing technology10.1016/j.jmapro.2022.10.060 ↗
9. A continuous wave technique for the measurement of the elastic properties of cortical bone10.1016/0021-9290(84)90029-0 ↗
10. ASTM International · 2017
11. ASTM International · 2018
12. ASTM International · 2024
13. Atec · 2025
14. Manufacture by selective laser melting and mechanical behavior of commercially pure titanium10.1016/j.msea.2013.11.038 ↗
15. Metal additive manufacturing of lattice-based orthopedic implants: A comprehensive review of requirements and design strategies10.1016/j.mser.2025.101075 ↗
16. Mechanical failure of total hip arthroplasties and associated risk factors10.1007/s00402-022-04353-0 ↗
17. Role of powder particle size on laser powder bed fusion processability of AlSi10mg alloy
18. In vivo damage of the head-neck junction in hard-on-hard total hip replacements: effect of femoral head size, metal combination, and 12/14 taper design10.3390/ma10070733 ↗
19. Development and mechanical characterization of porous titanium bone substitutes10.1016/j.jmbbm.2012.01.008 ↗
20. An overview of residual stresses in metal powder bed fusion
21. Mechanical properties of Ti6Al4V fabricated by laser powder bed fusion: A review focused on the processing and microstructural parameters influence on the final properties10.3390/met12060986 ↗
22. The effect of patient age at intervention on risk of implant revision after total replacement of the hip or knee: a population-based cohort study10.1016/S0140-6736(17)30059-4 ↗
23. Near-threshold fatigue crack growth rates of laser powder bed fusion produced Ti-6Al-4V10.1016/j.actamat.2020.07.049 ↗
24. Fatigue limit of Ti6Al4V alloy produced by selective laser sintering10.1016/j.prostr.2016.06.394 ↗
25. Architected cellular materials: A review on their mechanical properties towards fatigue-tolerant design and fabrication10.1016/j.mser.2021.100606 ↗
26. Standardized loads acting in hip implants10.1371/journal.pone.0155612 ↗
27. Realistic loads for testing hip implants10.3233/BME-2010-0616 ↗
28. Different post-processing methods to improve fatigue properties of additively built Ti-6Al-4V alloy10.1016/j.ijfatigue.2023.107850 ↗
29. Structural and hemodynamic analysis of weaire-phelan scaffolds made of ti-alloy as bone replacement component: A preclinical investigation10.1371/journal.pone.0312880 ↗
30. Mechanics and long-term stability of porous titanium scaffolds with rhombic dodecahedrons
31. Biomet, Z., 2026. G7 Acetabular System, URL https://www.zimmerbiomet.com/en/products-and-solutions/specialties/hip/g7-acetabular-system.html.
32. Assessment of the effect of isolated porosity defects on the fatigue performance of additive manufactured titanium alloy
33. Fabrication and optimisation of Ti-6Al-4V lattice-structured total shoulder implants using laser additive manufacturing10.3390/ma15093095 ↗
34. Bone plates runout prediction through tensile strength and geometric properties for regulatory mechanical testing10.1007/s10439-023-03363-2 ↗
35. Aseptic loosening of pedicle screw as a result of metal wear debris in a pediatric patient10.1097/BRS.0b013e3182793e51 ↗
36. Total hip replacement pseudotumoral osteolysis
37. Influence of particle morphology and size distribution on the powder flowability and laser powder bed fusion manufacturability of Ti-6Al-4V alloy
38. Review of wear mechanisms in hip implants: Paper I – General10.1016/j.matdes.2003.11.010 ↗
39. The design of additively manufactured lattices to increase the functionality of medical implants10.1016/j.msec.2018.10.052 ↗
40. A review on the recent advances concerning the fatigue performance of titanium alloys for orthopedic applications10.1557/s43578-020-00087-0 ↗
41. Elucidation of dross formation in laser powder bed fusion at down-facing surfaces: Phenomenon-oriented multiphysics simulation and experimental validation
42. Charles, A., Elkaseer, A., Thijs, L., Scholz, S., 2021. Effect of build platform location and part orientation on dimensional accuracy of down-facing surfaces in LPBF. In: Proceedings of the Conference: World Congress on Micro and Nano Manufacturing.
43. Comparative study of fatigue properties of Ti-6Al-4V specimens built by electron beam melting (EBM) and selective laser melting (SLM)10.1016/j.matchar.2018.03.028 ↗
44. Recent development in beta titanium alloys for biomedical applications10.3390/met10091139 ↗
45. The effect of microstructure on the fatigue behavior of titanium alloy graded porous structures fabricated by selective laser melting10.1016/j.jmrt.2023.10.281 ↗
46. Chen · 2023
47. Accelerated method for determining the fatigue limit of trabecular bone10.3390/ma18020232 ↗
48. Orthopaedic implant failure: aseptic implant loosening–the contribution and future challenges of mouse models in translational research10.1042/CS20130338 ↗
49. CSIRO · 2014
50. Measurement of the mechanical properties of bone: a recent history10.1007/s11999-009-0784-z ↗
51. Influence of layer thickness and post-process treatments on the fatigue properties of CoCr scaffolds produced by laser powder bed fusion
52. Fatigue and biological properties of Ti-6Al-4V ELI cellular structures with variously arranged cubic cells made by selective laser melting10.1016/j.jmbbm.2017.11.044 ↗
53. The role of node fillet, unit-cell size and strut orientation on the fatigue strength of Ti-6Al-4V lattice materials additively manufactured via laser powder bed fusion10.1016/j.ijfatigue.2020.105946 ↗
54. Comparative analysis of current 3D printed acetabular titanium implants
55. Comparison of in vivo measured loads in knee, hip and spinal implants during level walking10.1016/j.jbiomech.2016.11.060 ↗
56. Polyethylene wear in retrieved reverse total shoulder components10.1016/j.jse.2011.03.012 ↗
57. Efficient optimization framework for L-PBF fatigue enhanced Ti6Al4V lattice component10.1016/j.matdes.2023.111975 ↗
58. Effects of applied stress ratio on the fatigue behavior of additively manufactured porous biomaterials under compressive loading10.1016/j.jmbbm.2016.11.022 ↗
59. Scientific, technological and economic issues in metal printing and their solutions10.1038/s41563-019-0408-2 ↗
60. Additive manufacturing of metallic components–process, structure and properties10.1016/j.pmatsci.2017.10.001 ↗
61. Current interpretations on the in vivo response of bone to additively manufactured metallic porous scaffolds: a review
62. Mechanical testing standards of orthopedic implants10.1007/978-3-319-20777-3_5 ↗
63. Compression fatigue behavior of gyroid porous titanium scaffolds manufactured by laser powder bed fusion for bone-implant applications10.1016/j.ijfatigue.2025.109136 ↗
64. A methodological framework to model cumulative energy demand and production costs for additive and conventional manufacturing approaches
65. A new method with ultrasonic mechanism for efficient depowdering of parts produced by electron beam melting10.1051/meca/2022023 ↗
66. Biocompatibility of β-stabilizing elements of titanium alloys
67. Design optimization of additively manufactured titanium lattice structures for biomedical implants10.1007/s00170-020-05982-8 ↗
68. Optimising β-Ti21S alloy lattice structures for enhanced femoral implants: a study on mechanical and biological performance10.3390/ma18010170 ↗
69. Additive manufacturing of porous titanium metaphyseal components: early osseointegration and implant stability in revision knee arthroplasty10.1016/j.jcot.2020.10.042 ↗
70. Computer-generated patient models for reconstruction of cranial and facial deformities10.1097/00001665-199811000-00011 ↗
71. How long does a hip replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up10.1016/S0140-6736(18)31665-9 ↗
72. How long does a knee replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up10.1016/S0140-6736(18)32531-5 ↗
73. A method to design biomimetic scaffolds for bone tissue engineering based on Voronoi lattices10.1080/17452759.2016.1172301 ↗
74. Fatigue behaviour of additive manufactured materials: An overview of some recent experimental studies on Ti-6Al-4V considering various processing and loading direction effects10.1111/ffe.13000 ↗
75. Uniaxial and multiaxial fatigue life prediction of the trabecular bone based on physiological loading: a comparative study10.1007/s10439-015-1305-8 ↗
76. Electrochemical-based surface enhancement of additively manufactured Ti-6Al-4V complex structures10.1007/s11665-021-05512-x ↗
78. Reconstruction of an extensive midfacial defect using additive manufacturing techniques10.1111/jopr.12487 ↗
79. Defects as a root cause of fatigue weakening of additively manufactured AlSi10Mg components10.1016/j.tafmec.2020.102611 ↗
80. Surface modification–A step forward to overcome the current challenges in orthopedic industry and to obtain an improved osseointegration and antimicrobial properties10.1016/j.matchemphys.2019.122579 ↗
81. Osteoinduction of porous Ti implants with a channel structure fabricated by selective laser melting10.1016/j.actbio.2011.01.037 ↗
82. Quasi-static and fatigue performance of Ti-6Al-4V triply periodic minimal surface scaffolds manufactured via laser powder bed fusion for hard-tissue engineering10.1016/j.rineng.2024.103101 ↗
83. Effect of processing on microstructure, mechanical properties, corrosion and biocompatibility of additive manufacturing Ti-6Al-4V orthopaedic implants10.1038/s41598-025-98349-6 ↗
84. Failure of fracture plate fixation10.5435/00124635-200910000-00007 ↗
85. Surface, microstructure, and tensile deformation characterization of LPBF SS316L microstruts micromachined with femtosecond laser10.1016/j.matdes.2021.110045 ↗
86. The influence of laser parameters, scanning strategies and material on the fatigue strength of a stochastic porous structure
87. Vacuum heat treatments of titanium porous structures
88. The influence of additive manufacturing processing parameters on surface roughness and fatigue life10.1016/j.ijfatigue.2019.03.025 ↗
89. Critical review of LPBF metal print defects detection: Roles of selective sensing technology10.3390/app14156718 ↗
90. Structure-property relationships of imperfect additively manufactured lattices based on triply periodic minimal surfaces10.1016/j.matdes.2022.111036 ↗
91. Fatigue life of additively manufactured Ti–6Al–4V in the very high cycle fatigue regime10.1016/j.ijfatigue.2016.05.018 ↗
92. Defect-dependent fatigue properties of β Ti-42Nb processed by laser powder bed fusion10.1016/j.mtcomm.2025.111733 ↗
93. Laser powder bed fusion (LPBF) of commercially pure titanium and alloy development for the LPBF process10.3389/fbioe.2023.1260925 ↗
94. Similarity in the fatigue behavior of trabecular bone across site and species10.1016/S0021-9290(03)00245-8 ↗
95. Bone remodeling10.1196/annals.1365.035 ↗
96. Preclinical trial of a novel surface architecture for improved primary fixation of cementless orthopaedic implants10.1016/j.clinbiomech.2014.07.007 ↗
97. On the difference of fatigue strengths from rotating bending, four-point bending, and cantilever bending tests10.1016/S0308-0161(00)00080-6 ↗
98. Solid-lattice hip prosthesis design: Applying topology and lattice optimization to reduce stress shielding from hip implants
99. Multiscale modeling of fatigue crack propagation in additively manufactured porous biomaterials10.1016/j.ijfatigue.2018.05.006 ↗
100. Effect of surface topography on the fatigue behavior of additively manufactured Ti6Al4V and CoCr alloys10.1016/j.msea.2024.146821 ↗