journal article·2026-09Open access

TiNbSn alloy spine rods resistant to fatigue fracture and flattening

Shuji Hanada, Hitoshi Soyama, Toshimi Aizawa, Yu Mori, Ko Hashimoto, Satoshi Semboshi, Hiroaki Matsumoto

Abstract

The critical issues of fatigue fracture and flattening in the Ti-6Al-4V and CoCrMo spine rods for spine deformity correction surgery remain unresolved. To address them we propose a hypothesis that fatigue fracture stems from crystal defects and residual stresses, and flattening originates from the Bauschinger effect. To test the hypothesis, TiNbSn alloy spine rods with an apex radius of 120 mm (R120) were prepared by heating an as-swaged TiNbSn rod at 400°C for 5 h ("warm-contoured") using a rod fixing device designed to shape the rod while minimizing plastic deformation to reduce crystal defects. The warm-contoured TiNbSn spine rod exhibited a compressive residual stress of approximately 150 MPa at both concave and convex apices, while Ti-6Al-4V spine rod contoured to R120 using a bender demonstrated a tensile residual stress of around 400 MPa at the concave apex. Three point bending tests revealed that Ti-6Al-4V, CoCrMo and TiNbSn (heat-treated at 400°C for 5 h) spine rods contoured to R120 using a bender indicated significantly low yielding load (less than 200 N) under reverse loading, while the TiNbSn spine rod that was warm-contoured to R120 without using a bender demonstrated an extremely high yielding load (around 1000 N) when subjected to reverse loading. It is concluded from the obtained results on the residual stress measurements and three point bending properties that the warm-contoured TiNbSn rods are resistant to fatigue fracture and flattening.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Shape Memory Alloy Transformations · Fatigue and fracture mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (53)

Show source-provided references
1. Titanium vs cobalt chromium: what is the best rod material to enhance adolescent idiopathic scoliosis correction with sublaminar bands?10.1007/s00586-016-4838-0 ↗
2. Spine rod straightening as a possible cause for revision10.1007/s10856-017-5935-2 ↗
3. Risk factors for rod fracture after posterior correction of adult spinal deformity with osteotomy: a restrospective case-series
4. Rod angulation relationship with thoracic kyphosis after adolescent idiopathic scoliosis posterior instrumentation10.3390/children11010029 ↗
5. Slip and fatigue crack formation processes in an α/β titanium alloy in relation to crystallographic texture on different scales10.1016/j.actamat.2008.04.036 ↗
6. Mid-term results of a new femoral prosthesis using Ti-Nb-Sn alloy with low Young's modulus10.1186/s12891-021-04879-1 ↗
7. Postoperative changes in spinal rod contour in adolescent idiopathic scoliosis - an in vivo deformation study10.1097/BRS.0b013e318252ccbe ↗
8. Mechanical and microstructural single-crystal Bauschinger effects: observation of reversible plasticity in copper during bending10.1016/j.actamat.2010.07.023 ↗
9. Optimising mechanical properties in alpha + beta titanium alloys10.1016/S0921-5093(97)00784-3 ↗
10. Strategies for residual stress adjustment in bulk metal forming10.1007/s00419-021-01903-7 ↗
11. The fate of patients with adult spinal deformity incurring rod fracture after thoracolumbar fusion10.1016/j.wneu.2017.07.061 ↗
12. Low Young's modulus of cold groove-rolled β Ti–Nb–Sn alloys for orthopedic applications10.1016/j.msea.2020.140645 ↗
13. Effect of swaging on Young׳s modulus of β Ti–33.6Nb–4Sn alloy10.1016/j.jmbbm.2013.10.027 ↗
14. Fabrication of a high-performance hip prosthetic stem using β Ti–33.6Nb–4Sn10.1016/j.jmbbm.2013.11.002 ↗
15. A model for time dependent strain accumulation and damage at low temperatures in Ti-6Al-4V10.1016/j.msea.2013.02.070 ↗
16. Effects of size of micro texture regions on the dwell fatigue properties of Ti-6Al-4V10.2355/isijinternational.ISIJINT-2023-205 ↗
17. Strain localization and fatigue crack formation at (0001) twist boundaries in titanium alloys10.1016/j.actamat.2021.117227 ↗
18. Rod fracture after multiple-rod constructs for adult spinal deformity10.3171/2019.9.SPINE19913 ↗
19. A 3D parameter can guide concave rod contour for the correction of hypokyphosis in adolescent idiopathic scoliosis10.1097/BRS.0000000000003566 ↗
20. Strain-induced martensitic transformation near twin boundaries in a biomedical Co-Cr-Mo alloy with negative stacking fault energy10.1016/j.actamat.2012.11.041 ↗
21. Identification of optimized rod shapes to guide anatomical spinal reconstruction for adolescent thoracic idiopathic scoliosis10.1002/jor.24118 ↗
22. Effects of multilevel facetectomy and screw density on postoperative changes in spinal rod contour in thoracic adolescent idiopathic scoliosis surgery10.1371/journal.pone.0161906 ↗
23. Crack initiation mechanisms in Ti-6Al-4V subjected to cold dwell-fatigue, low-cycle fatigue and high-cycle fatigue loadings10.1016/j.actamat.2022.118560 ↗
24. Fractures in tensile deformation of biomedical Co-Cr-Mo-N alloys10.1016/j.matlet.2010.12.007 ↗
25. Effects of minimally invasive lateral lumber interbody fusion with accessory rod technique on rod fracture in adult spinal deformity surgery: analysis of 239 patients10.1097/BRS.0000000000004920 ↗
26. Rod fracture in adult spinal deformity surgery fused to the serum: prevalence, risk factors, and impact on health-related quality of life in 526 patients10.1016/j.spinee.2018.02.008 ↗
27. Multi-dimensional study of the effect of early slip activity on fatigue crack initiation in a near-α titanium alloy10.1016/j.actamat.2022.117967 ↗
28. Titanium alloys in total joint replacement-a materials science perspective10.1016/S0142-9612(97)00146-4 ↗
29. Microscopic mechanism of plastic deformation in a polycrystalline Co-Cr-Mo alloy with a single hcp phase10.1016/j.actamat.2013.11.005 ↗
30. Beta TiNbSn alloys with low Young’s modulus and high strength10.2320/matertrans.46.1070 ↗
31. The bone tissue compatibility of a new Ti-Nb-Sn alloy with a low Young’s modulus10.1016/j.actbio.2011.02.008 ↗
32. Are there 3D changes in spine and rod shape in the 2 years after adolescent idiopathic scoliosis instrumentation?10.1097/BRS.0000000000002056 ↗
33. Choice of rods in surgical treatment of adolescent idiopathic scoliosis: what are the clinical implications of biomedical properties?- A review of the literature10.14245/ns.1836050.025 ↗
34. The role of extrusions and intrusions in fatigue crack initiation10.1016/j.engfracmech.2017.03.006 ↗
35. Adult spinal deformities: can patient-specific rods change the preoperative planning into clinical reality? Feasibility study and preliminary results about 77 cases10.1155/2020/6120580 ↗
36. Sagittal reduction of spinal derformity: superior versus lateral screw-rod connection
37. 5.5- mm Cobalt- chrome vs 6- mm titanium alloy rods in surgical treatment of Lenke 1 adolescent idiopathic scoliosis with high- density pedicle screws and direct vertebral rotation on differently shaped rods: a retrospective comparative cohort study10.14444/8381 ↗
38. Would CoCr rods provide better correctional forces than stainless steel or titanium for rigid scoliosis curves?10.1097/BSD.0b013e31826a0f19 ↗
39. Understanding the contribution of normal-fatigue and static loading to the dwell fatigue in a near-alpha titanium alloy10.1007/s11661-004-0058-z ↗
40. Crystallography of fracture facets in a near-alpha titanium alloy10.1007/s11661-006-0144-5 ↗
41. Determination of crystallographic orientation of dwell- fatigue fracture facets in Ti-6242 alloy10.1007/s10853-006-0252-z ↗
42. Observations on the faceted initiation site in the dwell-fatigue tested Ti-6242 alloy: crystallographic orientation and size effects10.1007/s11661-006-0095-x ↗
43. Assessment of symptomatic rod fracture after posterior instrumented fusion for adult spinal deformity10.1227/NEU.0b013e3182672aab ↗
44. Prospective multicenter assessment of risk factors for rod fracture following surgery for adult spinal deformity10.3171/2014.9.SPINE131176 ↗
45. Patient-specific rods for thoracic kyphosis correction in adolescent idiopathic scoliosis surgery: preliminary results
46. The effects of submerged laser peening, cavitation peening, and shot peening on the improvement of the torsional fatigue strength of powder bed fused Ti6Al4V produced through laser sintering10.1016/j.ijfatigue.2024.108348 ↗
47. In vivo deformation of anatomically pre-bent rods in thoracic adolescent idiopathic scoliosis10.1038/s41598-021-92187-y ↗
48. Plastic deformation behavior of single-crystalline martensite of Ti-Nb shape memory alloy10.1038/s41598-017-15877-6 ↗
49. Investigation of surface finish and fatigue life of laser powder bed fused Ti-6Al-4V10.1016/j.ijfatigue.2024.108558 ↗
50. Grain-scale stress states in microtextured Ti64: implications for dwell fatigue10.1007/s11837-022-05423-9 ↗
51. Residual stress and its role in failure10.1088/0034-4885/70/12/R04 ↗
52. Mechanical analysis of notch-free pre-bent rods for spinal deformity surgery10.1097/BRS.0000000000003269 ↗
53. Rod fracture after multi-rod technique for adult spinal deformity: a case report