Hybrid III lumbar spinal column injury risk curves from vertical impact
Source abstract
Abstract
Musculoskeletal injuries from underbody blasts due to the detonation of improvised explosive devices (IED) impart dynamic loading to the human vertebral column via the pelvis region, and the primary insult from the IED is absorbed first by the lumbar spine before it traverses to the thoracic and cervical spines. Injuries from these scenarios have been documented in many clinical and retrospective studies. Although the dynamic response index continues to be used to predict lumbar spine injuries, it is based on the accelerations of the seat pan. A need exists to develop lumbar spine injury criteria for human surrogates. The objective of this study was to develop lumbar spine injury criteria, in the form of injury assessment risk curves, specific to the Hybrid III anthropomorphic test device under the underbody blast vertical impact load vector. The Hybrid III human surrogate was prepared with load cells at the superior and inferior ends of the lumbar spinal column. The dynamic impact loading was applied to the inferior end of the spinal column spine using a custom vertical accelerator device. The peak axial, shear, and resultant forces at the ends of the column were obtained. The compressive force-based injury mechanism was confirmed with results from previous human cadaver lumbar spine results conducted under the same experimental protocol. The parametric survival analysis using the Weibull distribution was used to develop lumbar spine injury assessment risk curves, and using the ±95% confidence interval bounds, the quality of the risk curves at discrete injury probability levels were calculated for all metrics. At the superior end, at the mid-risk level, the estimated axial force was 14.7 kN, shear force was 2.1 kN, and resultant force was 14.8 kN, and at the 10% risk level, the estimated axial force was 6.7 kN, shear force was 0.9 kN, and resultant force was 6.7 kN. At the inferior end and at the mid-risk level, the estimated axial force was 16.7 kN, shear force was 2.8 kN, and resultant force was 16.8 kN. At the 10% risk level, the estimated axial force was 7.2 kN, shear force was 0.8 kN, and resultant force was 7.3 kN. The confidence intervals and quality of risk curves are reported in the paper. Axial forces were consistently greater than shear forces at both ends, mimicking the injury mechanisms based on fractures reported in clinical and cadaver studies from underbody blast loading scenarios. Injury risk curves at the superior end of the spine were shifted to the left for the axial, shear, and resultant forces compared to the inferior end, confirming the energy absorption and transmittal of the axial force along the spinal column. Resultant forces can be used as injury criteria because shear forces were low. The present survival analysis-based injury assessment risk curves can be used as a preliminary Hybrid III lumbar spinal column injury criteria for improving the Warfighter safety and evaluating current and future military vehicles under vertical impacts.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Automotive and Human Injury Biomechanics · Spinal Fractures and Fixation Techniques · Spine and Intervertebral Disc Pathology
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. Backaitis · 1994
2. Dynamic simulation techniques for the design of escape systems: current applications and future air force requirements
3. Human foot-ankle injuries and associated risk curves from under body blast loading conditions
4. Analysis of the frequency and mechanism of injury to warfighters in the under-body blast environment
5. Comparison of ATD to PMHS response in the under-body blast environment
6. Civil aviation crash injury protection
7. 2001 · 214
8. Foster · 1977
9. Retrospective review of lumbosacral dissociations in blast injuries10.1097/BRS.0b013e3182077fd7 ↗
10. Combat-related lumbopelvic dissociation treated with L4 to ilium posterior fusion10.1016/j.spinee.2011.05.017 ↗
11. Comparison of cervical vertebrae rotations for PMHS and BioRID II in rear impacts10.1080/15389588.2013.799280 ↗
12. Development of side impact thoracic injury criteria and their application to the modified ES-2 dummy with rib extensions (ES-2re)
13. Prominent injury types in vehicle underbody blast10.1093/milmed/usy322 ↗
14. 2023
15. Expanded combined loading injury criterion for the human lumbar spine under dynamic compression10.1007/s10439-024-03570-5 ↗
16. The human lumbar spine during high-rate under seat loading: a combined metric injury criteria10.1007/s10439-021-02823-x ↗
17. A note on the jackknife, the bootstrap and the delta method estimators of bias and variance10.1093/biomet/70.3.719 ↗
18. Multiple associated injuries are common with spine fractures during war10.1016/j.spinee.2011.10.001 ↗
19. Normalization and scaling for human response corridors and development of injury risk curve
20. Injury criteria and motor vehicle regulations
21. Injuries from roadside improvised explosive devices
22. A new understanding of the mechanism of injury to the pelvis and lower limbs in blast10.3389/fbioe.2020.00960 ↗
23. Development of an injury risk curve for pelvic fracture in vertical loading environments10.1080/15389588.2018.1532221 ↗
24. Pelvic, spinal and extremity wounds among combat-specific personnel serving in Iraq and Afghanistan (2003-2011): a new paradigm in military musculoskeletal medicine10.1016/j.injury.2013.08.001 ↗
25. Treatment of a patient with Lumbosacral and pelvic fractures due to a blast injury without surgical stabilization10.15761/CCRR.1000217 ↗
26. Identifying spinal injury patterns in underbody blast to develop mechanistic hypotheses10.1097/BRS.0000000000001213 ↗
27. Dynamic models of the human body
28. Retrospective analysis of injuries in underbody blast events: 2007-201010.1093/milmed/usx216 ↗
29. Human lumbar spinal column injury criteria from vertical loading at the base: applications to military environments10.1016/j.jmbbm.2020.103690 ↗
30. Hybrid III dummy lumbar spine responses under vertical impact loading
31. Vertical accelerator device to apply loads simulating blast environments in the military to human surrogates10.1016/j.jbiomech.2015.06.008 ↗