journal article·2026-10

Finite element analysis in tibial plateau fractures: a systematic review of literature

Pablo Besa, Catalina Vidal, José Tomás Ramos-Rojas, Eithan Goldbaum, Marcelo E. Andia, Joaquín Mura

Publisher page

Abstract

Purpose The objective of this study was to systematically summarize and critically evaluate the available evidence on the biomechanical performance of fixation plates in the treatment of tibial plateau fractures. Methods This systematic review was conducted in accordance with PRISMA guidelines. A comprehensive search (from inception to September 2025) across multiple databases identified studies that used finite element (FE) models to assess orthopedic hardware in tibial plateau fractures. Inclusion criteria required the use of FE analysis with specific fixation methods. Data extraction and risk of bias assessment were performed independently by two reviewers using standardized tools. Results Thirty-one studies were included. Most reconstructed fracture models from patient-derived CT data or synthetic tibias. While all distinguished cortical from trabecular bone, few incorporated bone mineral density variations or applied physiological dynamic loading. Considerable heterogeneity was observed in material properties, boundary conditions, and meshing strategies, limiting reproducibility and cross-study comparability. Only a minority of models used subject-specific data or validated results against experimental or clinical benchmarks. All studies were classified as high risk of bias according to ROBFEAD criteria. Conclusion Current FE models for tibial plateau fractures are limited by a universally high risk of bias, predominantly relying on simplified geometries, omitting dynamic loading, and critically lacking mechanical validation. The marked heterogeneity among studies poses a major challenge to evidence synthesis and translation into surgical decision-making. Future research must prioritize patient-specific models, dynamic loading conditions, and standardized reporting to enhance clinical relevance.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone fractures and treatments · Total Knee Arthroplasty Outcomes · Hip and Femur Fractures

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (53)

Show source-provided references
1. Development of digital twins to optimize trauma surgery and postoperative management. A case study focusing on tibial Plateau fracture10.3389/fbioe.2021.722275 ↗
2. Utility of cement injection to stabilize split-depression tibial Plateau fracture by minimally invasive methods: a finite element analysis10.1016/j.clinbiomech.2018.05.002 ↗
3. Besa · 2023
4. Fixation of a split fracture of the lateral tibial Plateau with a locking screw plate instead of cannulated screws would allow early weight bearing: a computational exploration10.1007/s00264-015-3106-y ↗
5. Applications of finite element modeling in biomechanical analysis of foot arch deformation: a scoping review10.1115/1.4062311 ↗
6. Newly designed anterolateral and posterolateral locking anatomic plates for lateral tibial Plateau fractures: a finite element study10.1186/s13018-017-0531-1 ↗
7. Biomechanical aspects of the posteromedial split in bicondylar tibial Plateau fractures-a finite-element investigation10.1007/s00068-020-01538-3 ↗
8. Optimizing outcomes after operative treatment bicondylar tibial Plateau fractures – time for innovation
9. Finite element analysis of the amputated lower limb: a systematic review and recommendations10.1016/j.medengphy.2017.02.008 ↗
10. Comparative analysis of tibial Plateau fracture osteosynthesis: a finite element study10.1016/j.jmbbm.2022.105392 ↗
11. A finite element analysis of the supportive effect of a new type of rotary support plate on lateral tibial Plateau fractures10.21037/atm-22-4529 ↗
12. Mechanical evaluation of large-size fourth-generation composite femur and tibia models10.1007/s10439-009-9887-7 ↗
13. A systematic review of biomechanical studies utilising finite element analysis in hallux valgus deformity10.1016/j.fas.2025.05.005 ↗
14. The mechanical properties of human tibial trabecular bone as a function of metaphyseal location10.1016/0021-9290(83)90097-0 ↗
15. Fractures around the hip: inducing life-like fractures as a basis for enhanced surgical training10.1007/s00402-020-03628-8 ↗
16. Structural properties of fourth-generation composite femurs and tibias10.1016/j.jbiomech.2008.08.013 ↗
17. Stress and stability of plate-screw fixation and screw fixation in the treatment of schatzker type IV medial tibial Plateau fracture: a comparative finite element study10.1186/s13018-015-0325-2 ↗
18. Jacofsky · 2006
19. Medium-term results after complex intra-articular fractures of the tibial Plateau10.1007/s00776-013-0404-3 ↗
20. Finite element analysis of a novel anatomical plate in posterolateral Plateau fractures10.3389/fsurg.2024.1346462 ↗
21. Interfragmentary compression force and fixation stability of lateral tibial Plateau fractures in normal and osteoporotic bones10.1002/jor.25832 ↗
22. Application of a combined cancellous lag screw enhances the stability of locking plate fixation of osteoporotic lateral tibial Plateau fracture by providing interfragmentary compression force10.1186/s13018-024-04564-8 ↗
23. Finite element analysis of fracture fixation10.1007/s11914-021-00690-y ↗
24. Feasibility and mechanical strength evaluation of new customized implants for tibial Plateau fractures fixation10.1111/os.70041 ↗
25. Importance of the posterior plate in three‐column tibial Plateau fractures: a finite element analysis and clinical validation10.1111/os.14021 ↗
26. The study of biomechanics and finite element analysis on a novel plate for tibial Plateau fractures via anterolateral supra-fibular-head approach10.1038/s41598-023-40842-x ↗
27. Early predictors of long-term work disability after major limb trauma10.1097/01.ta.0000195985.56153.68 ↗
28. Finite element method in internal and hybrid external fixation of tibial condylar fractures: a comparative application study10.1615/JLongTermEffMedImplants.v21.i4.10 ↗
29. Development and validation of risk of bias tool for the use of finite element analysis in dentistry (ROBFEAD)10.1080/10255842.2022.2148465 ↗
30. Surgical fixation methods for tibial Plateau fractures, in: the cochrane collaboration
31. Stresses and deformations of an osteosynthesis plate in a lateral tibia Plateau fracture. Biomedizinische technik10.1515/bmt-2021-0166 ↗
32. Angular-stable locking plate fxation of tibial Plateau fractures-clinical and radiological midterm results in 101 patients
33. A review of the management of tibial Plateau fractures10.1007/s12306-017-0514-8 ↗
34. A novel design of a plate for posterolateral tibial Plateau fractures through traditional anterolateral approach10.1038/s41598-018-34818-5 ↗
35. The study of biomechanics and clinical anatomy on a novel plate designed for posterolateral tibial Plateau fractures via anterolateral approach10.3389/fbioe.2022.818610 ↗
36. Relations of mechanical properties to density and CT numbers in human bone10.1016/1350-4533(95)97314-F ↗
37. Finite element analysis of Bi-condylar tibial Plateau fractures to assess the effect of coronal splits10.1016/j.medengphy.2020.07.026 ↗
38. A systematic review of finite element analysis in running footwear biomechanics: insights for running-related musculoskeletal injuries10.52082/jssm.2025.370 ↗
39. Mid- to long-term functional outcome after open reduction and internal fixation of tibial Plateau fractures10.1016/j.injury.2015.05.035 ↗
40. A finite element analysis of relationship between fracture, implant and tibial tunnel10.1038/s41598-021-81401-6 ↗
41. Inducing life-like distal radius fractures in human cadaveric specimens: a tool for enhanced surgical training10.1007/s00402-019-03313-5 ↗
42. Biomechanical analysis of internal fixation system stability for tibial Plateau fractures10.3389/fbioe.2023.1199944 ↗
43. Higher interfragmentary compression force improves lateral tibial Plateau fracture stability using locking plate fixation: experimental and simulation verification10.1186/s12891-024-08214-2 ↗
44. Preliminary exploration of finite element biomechanical preoperative planning for complex tibial Plateau fractures
45. Different internal fixation methods for Hoffa-like fractures of the tibial Plateau: a finite element analysis10.3389/fmed.2023.1172377 ↗
46. A novel locking buttress plate designed for simultaneous medial and posterolateral tibial Plateau fractures: concept and comparative finite element analysis10.1111/os.13660 ↗
47. Newly designed plate for the treatment of posterolateral tibial Plateau fractures: a finite element analysis10.1186/s13018-024-04686-z ↗
48. Stability of internal fixation systems based on different subtypes of schatzker II fracture of the tibial Plateau: a finite element analysis10.3389/fbioe.2022.973389 ↗
49. Biomechanical study of a new rim plate fixation strategy for two kinds of posterolateral depression patterns of tibial Plateau fractures: a finite element analysis10.1186/s13018-023-04315-1 ↗
50. Biomechanics and finite element analysis of a novel plate designed for posterolateral tibial Plateau fractures via the anterolateral approach
51. Finite element analysis of three internal fixations for the posteromedial split fracture fragment in tibial Plateau fractures10.1080/10255842.2024.2399036 ↗
52. Finite element models of the human shoulder complex: a review of their clinical implications and modelling techniques10.1002/cnm.2777 ↗
53. Title of the study: finite element analysis of five internal fixation modalities for schatzker type IV‒C tibial Plateau fractures10.1186/s12891-025-08770-1 ↗