journal article·2026-10Open access

Numerical modeling of textile-based LCE actuators for conformal cardiac surface interaction

Achyuth Ram Annadata, Ram Prasad Velusamy, Tobias Lang, Thomas Gereke, Chokri Cherif

Abstract

Textile based actuators have emerged as promising candidates for biomedical applications such as ventricular assist systems or artificial myocardium. This study investigates the mechanical coupling between Liquid Crystal Elastomer (LCE) fibers and a soft anatomical model of the human left ventricle (LV). In this work, a simplified LV geometry was modeled as a hyperelastic and wrapped with beam element textiles representing plain and atlas weave types. LCE contraction was simulated via thermally induced strain along the yarn axis. Simulations were performed using LS-DYNA, to evaluate surface contact coverage, mean and peak contact pressures, and resultant displacements across increasing LCE strain levels. Results show that the plain weave achieve superior conformity and more efficient force transmission. This work provides new insights into fiber geometry coupling and offers a simulation driven foundation for designing textile LCE systems tailored for soft robotic and cardiac applications.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Elasticity and Material Modeling · Advanced Materials and Mechanics · Soft Robotics and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. Dilated cardiomyopathy
2. A bi-ventricular cardiac atlas built from 1000+ high resolution mr images of healthy subjects and an analysis of shape and motion10.1016/j.media.2015.08.009 ↗
3. Barbero · 2017
4. Generation of liquid crystal elastomer fibers via a wet spinning technology with two-stage crosslinking10.3390/polym17040494 ↗
5. Material properties of CorCap passive cardiac support device10.1016/j.athoracsur.2012.07.036 ↗
6. Population-based studies of myocardial hypertrophy: high resolution cardiovascular magnetic resonance atlases improve statistical power10.1186/1532-429X-16-16 ↗
7. Delgadillo · 2007
8. Modeling the mechanical properties of textile-reinforced composites with a near micro-scale approach10.1016/j.compstruct.2015.09.010 ↗
9. Interaction of the mechano-electrical feedback with passive mechanical models on a 3D rat left ventricle: a computational study10.3389/fphys.2019.01041 ↗
10. A face-based smoothed finite element method for hyperelastic models and tissue growth
11. Cardiac mechanostructure: Using mechanics and anisotropy as inspiration for developing epicardial therapies in treating myocardial infarction
12. Modeling the dispersion in electromechanically coupled myocardium10.1002/cnm.2575 ↗
13. A review of numerical models for 3D woven composite reinforcements10.1016/j.compstruct.2018.10.085 ↗
14. Mechanism underlying mechanical dysfunction in the border zone of left ventricular aneurysm: A finite element model study10.1016/S0003-4975(00)02338-9 ↗
15. Mechanics of active contraction in cardiac muscle: Part II—cylindrical models of the systolic left ventricle10.1115/1.2895474 ↗
16. Mitral valve repair without cardiopulmonary bypass or atriotomy using the coapsys device: device design and implantation procedure in canine functional mitral regurgitation model
17. Modelling and simulating textile structures using TexGen
18. Experimental and clinical studies with the paracor cardiac restraint device10.1053/j.semtcvs.2005.09.006 ↗
19. Clinical evaluation of the CorCap cardiac support device in patients with dilated cardiomyopathy10.1016/j.athoracsur.2007.03.095 ↗
20. Beneficial effects of the CorCap cardiac support device: Five-year results from the acorn trial10.1016/j.jtcvs.2011.06.014 ↗
21. Towards the simulation of active cardiac mechanics using a smoothed finite element method10.1016/j.jbiomech.2020.110153 ↗
22. 3D composite reinforcement meso F. E. analyses based on X-ray computed tomography10.1016/j.compstruct.2015.07.005 ↗
23. Cardio-supportive devices (VRD & DCC device) and patches for advanced heart failure: A review, summary of state of the art and future directions10.1016/j.biopha.2018.03.049 ↗
24. Left ventricular restoration devices10.1007/s12265-014-9552-x ↗
25. Numerical modeling of the mechanical behavior of textile structures on the meso-scale for forming process simulations of composite 3D preforms
26. Finite element modelling of orthotropic material behaviour in pneumatic membranes10.1016/S0020-7683(01)00137-8 ↗
27. A modelling framework for composites containing 3D reinforcement10.1016/j.compstruct.2012.03.009 ↗
28. Clinical assessment of ventricular wall stress in understanding compensatory hypertrophic response and maladaptive ventricular remodeling10.3390/jcdd8100122 ↗
29. Optimizing epicardial restraint and reinforcement following myocardial infarction: Moving towards localized, biomimetic, and multitherapeutic options10.3390/biomimetics4010007 ↗
30. Design and features of the acorn CorCapTM cardiac support device: The concept of passive mechanical diastolic support10.1007/s10741-005-4637-x ↗
31. Biventricular finite element modeling of the acorn CorCap cardiac support device on a failing heart10.1016/j.athoracsur.2013.02.032 ↗