Patient-specific finite element models of human vertebrae with simulated osteolytic defects: Predictive accuracy of surface strain and endplate deflection

Giulia Fraterrigo, Enrico Schileo, Paolo Erani, Alessandro Gasbarrini, Luigi Falzetti, Cristina Bignardi, Fulvia Taddei, Massimiliano Baleani

Publisher page

Abstract

Approximately 40% of cancer patients develop spinal metastases, often leading to vertebral fragility fractures. Osteolytic metastases are the most severe, as they significantly alter strain distribution in bone tissue. This pilot study extends a previously validated experimental-computational framework for intact vertebrae to assess the accuracy of personalized finite element models (FEM) in the presence of controlled artificial lytic defects. Three human lumbar vertebrae (L3-L5) were tested in intact and defect conditions. Progressively enlarging hemispherical defects (10-25 mm diameter) were drilled within the trabecular bone through the caudal surface after endplate removal, without involving the cortical wall. A compressive load of 2 kN was homogeneously distributed on the cranial endplate. Surface displacements and strains were measured using Digital Image Correlation (DIC), and cranial endplate deflection using a linear displacement transducer (LVDT). Corresponding FEM were developed from CT data and validated against experimental measurements. Predicted and measured endplate deflection (R2 = 0.79) and vertebral wall displacements (R2 = 0.87-0.92) were significantly correlated across all defect sizes. Longitudinal strain predictions demonstrated good agreement with experimental data, with median relative errors across defect sizes ranging from -4% to +13%, comparably to the intact condition (+10%). Circumferential strains in defect conditions were consistently overestimated, similarly to the intact condition as well. In summary, the proposed FEM retained high accuracy in longitudinal strain prediction and captured vertebral endplate deflection even in the presence of large trabecular defects, although experimental limitations suggest modifying the caudal constraint in future studies.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone health and osteoporosis research · Management of metastatic bone disease · Spinal Fractures and Fixation Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (24)

Show source-provided references
1. Measurement of apparent mechanical properties of trabecular bone tissue: Accuracy and limitation of digital image correlation technique10.1016/j.jmbbm.2019.103542 ↗
2. Can Multi‐Vertebral CT‐Based Finite Element Models Accurately Predict Strains? An In Vitro Validation Study10.1002/cnm.70085 ↗
3. Mechanical assessment of the effects of metastatic lytic defect on the structural response of human thoracolumbar spine: EFFECT OF CRITICAL LYTIC DEFECT10.1002/jor.23154 ↗
4. Applying a homogeneous pressure distribution to the upper vertebral endplate: Validation of a new loading system, pilot application to human vertebral bodies, and finite element predictions of DIC measured displacements and strains10.1016/j.jmbbm.2023.105706 ↗
5. Spinal Loading Patterns From Biomechanical Modeling Explain the High Incidence of Vertebral Fractures in the Thoracolumbar Region10.1002/jbmr.3113 ↗
6. Biomechanical assessment of vertebrae with lytic metastases with subject-specific finite element models10.1016/j.jmbbm.2019.06.027 ↗
7. ALBA: Agile library for biomedical applications10.1016/j.softx.2025.102188 ↗
8. A nonlinear finite element model validation study based on a novel experimental technique for inducing anterior wedge-shape fractures in human vertebral bodies in vitro10.1016/j.jbiomech.2010.04.023 ↗
9. Computational Assessment of Fracture Risk in Vertebral Bodies With Simulated Defects: The Role of Baseline Strength and Tumor Size10.1002/cnm.70081 ↗
10. Prediction of vertebral failure under general loadings of compression, flexion, extension, and side-bending10.1016/j.jmbbm.2024.106827 ↗
11. The Role of the Size and Location of the Tumors and of the Vertebral Anatomy in Determining the Structural Stability of the Metastatically Involved Spine: a Finite Element Study10.1016/j.tranon.2018.03.002 ↗
12. Endplate deflection is a defining feature of vertebral fracture and is associated with properties of the underlying trabecular bone: ENDPLATE DEFLECTION AND VERTEBRAL FRACTURE10.1002/jor.22620 ↗
13. The European Spine Phantom — a tool for standardization and quality control in spinal bone mineral measurements by DXA and QCT10.1016/0720-048X(95)00631-Y ↗
14. A practical approach to optimizing the preparation of speckle patterns for digital-image correlation10.1088/0957-0233/25/10/107001 ↗
15. Experiment on Ex-Vivo Vertebral Body with Defect for Numerical Model Evaluation: Bone Metastasis
16. The importance of multidisciplinary care for spine metastases: initial tumor management10.1093/nop/npaa056 ↗
17. The role of bone metastases on the mechanical competence of human vertebrae10.1016/j.bone.2023.116814 ↗
18. Three-dimensional surface strain analyses of simulated defect and augmented spine segments: A biomechanical cadaveric study10.1016/j.jmbbm.2021.104559 ↗
19. CT-based finite element simulating spatial bone damage accumulation predicts metastatic human vertebrae strength and stiffness10.3389/fbioe.2024.1424553 ↗
20. Conventional finite element models estimate the strength of metastatic human vertebrae despite alterations of the bone’s tissue and structure10.1016/j.bone.2020.115598 ↗
21. An improved method for the automatic mapping of computed tomography numbers onto finite element models10.1016/S1350-4533(03)00138-3 ↗
22. Independent measurement of femoral cortical thickness and cortical bone density using clinical CT10.1016/j.media.2014.11.012 ↗
23. Burst Fracture in the Metastatically Involved Spine: Development, Validation, and Parametric Analysis of a Three-Dimensional Poroelastic Finite-Element Model10.1097/01.BRS.0000051910.97211.BA ↗
24. Subpixel displacement and deformation gradient measurement using digital image/speckle correlation (DISC)10.1117/1.1387992 ↗