journal article·2013-09

On the effect of prestrain and residual stress in thin biological membranes

Manuel K. Rausch, Ellen Kuhl

Publisher page

Abstract

Understanding the difference between ex vivo and in vivo measurements is critical to interpret the load carrying mechanisms of living biological systems. For the past four decades, the ex vivo stiffness of thin biological membranes has been characterized using uniaxial and biaxial tests with remarkably consistent stiffness parameters, even across different species. Recently, the in vivo stiffness was characterized using combined imaging techniques and inverse finite element analyses. Surprisingly, ex vivo and in vivo stiffness values differed by up to three orders of magnitude. Here, for the first time, we explain this tremendous discrepancy using the concept of prestrain. We illustrate the mathematical modeling of prestrain in nonlinear continuum mechanics through the multiplicative decomposition of the total elastic deformation into prestrain-induced and load-induced parts. Using in vivo measured membrane kinematics and associated pressure recordings, we perform an inverse finite element analysis for different prestrain levels and show that the resulting membrane stiffness may indeed differ by four orders of magnitude depending on the prestrain level. Our study motivates the hypothesis that prestrain is important to position thin biological membranes in vivo into their optimal operating range, right at the transition point of the stiffening regime. Understanding the effect of prestrain has direct clinical implications in regenerative medicine, medical device design, and and tissue engineering of replacement constructs for thin biological membranes.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Elasticity and Material Modeling · Cellular Mechanics and Interactions · Force Microscopy Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (51)

Show source-provided references
1. Abaqus 6.9, 2009. Analysis User's Manual. SIMULIA. Dassault Systèmes.
2. Anisotropic micro-sphere-based finite elasticity applied to blood vessel modelling10.1016/j.jmps.2008.09.005 ↗
3. Perspectives on biological growth and remodeling10.1016/j.jmps.2010.12.011 ↗
4. On the in vivo deformation of the mitral valve anterior leaflet10.1007/s10439-012-0524-5 ↗
5. Simulation of discontinuous damage incorporating residual stresses in circumferentially overstretched atherosclerotic arteries10.1016/j.actbio.2006.06.005 ↗
6. Spherical indentation of freestanding circular thin films in the membrane regime10.1016/j.jmps.2004.03.002 ↗
7. Rigid, complete annuloplasty rings increase anterior mitral valve leaflet strains in the normal beating ovine heart10.1161/CIRCULATIONAHA.110.011163 ↗
8. How do annuloplasty rings affect mitral annular strains in the normal beating ovine heart?10.1161/CIRCULATIONAHA.111.084046 ↗
10. Origin of axial prestretch and residual stress in arteries10.1007/s10237-008-0146-x ↗
11. Stress–strain characteristics of fresh and frozen human aortic and mitral leaflets and chordae tendineae. Implications for clinical use10.1016/S0022-5223(19)40619-3 ↗
12. Constitutive function, residual stress, and state of uniform stress in arteries10.1016/j.jmps.2012.02.005 ↗
13. Nondestructive analysis of mitral valve collagen fiber orientation
14. A three-constituent damage model for arterial clamping in computer-assisted surgery10.1007/s10237-012-0386-7 ↗
15. Change of residual strains in arteries due to hypertrophy caused by aortic constriction10.1161/01.RES.65.5.1340 ↗
16. What are the residual stresses doing in our blood vessels10.1007/BF02584301 ↗
17. Mitral-valve mechanics—Stress–strain characteristics of excised leaflets, analysis of its functional mechanics and its medical application10.1007/BF02478657 ↗
18. Anterior mitral leaflet curvature in the beating ovine heart. A case study using videofluoroscopic markers and subdivision surfaces10.1007/s10237-009-0176-z ↗
19. Mitral valve stiffening in end-stage heart failure10.1016/j.jtcvs.2005.04.019 ↗
20. Biaxial stress–stretch behavior of the mitral valve anterior leaflet at physiological strain rates10.1007/s10439-005-9027-y ↗
21. In vitro dynamic strain behavior of the mitral valve posterior leaflet10.1115/1.1894385 ↗
22. On the residual stress possible in an elastic body with material symmetry10.1007/BF00752113 ↗
23. Virtual configurations and constitutive equations for residually stressed bodies with material symmetry10.1023/A:1007459331524 ↗
24. A constitutive theory for biomembranes10.1115/1.2894095 ↗
25. Active stiffening of mitral valve leaflets in the beating heart10.1152/ajpheart.00120.2009 ↗
26. A saddle-shaped annulus reduces systolic strain on the central region of the mitral valve anterior leaflet10.1016/j.jtcvs.2007.08.037 ↗
27. The use of a virtual configuration in formulating constitutive equations for residually stretched elastic materials10.1007/BF00041874 ↗
28. Material properties of the ovine mitral valve anterior leaflet in vivo from inverse finite element analysis10.1152/ajpheart.00284.2008 ↗
29. Stress–strain behavior of mitral valve leaflets in the beating ovine heart10.1016/j.jbiomech.2009.05.018 ↗
30. Regional stiffening of the mitral valve anterior leaflet in the beating heart10.1016/j.jbiomech.2009.08.028 ↗
31. Stress/strain characteristics of porcine mitral valve tissue10.1111/j.1540-8191.1992.tb00777.x ↗
32. Anterior mitral leaflet curvature during the cardiac cycle in the normal ovine heart10.1161/CIRCULATIONAHA.110.961243 ↗
33. Biaxial mechanical behavior of excised porcine mitral valve leaflets
34. A constitutive law for mitral valve tissue10.1115/1.2834305 ↗
35. A fibre reorientation model for orthotropic multiplicative growth10.1007/s10237-006-0061-y ↗
36. Tissue engineering of human heart valve leaflets10.1007/s10439-005-8025-4 ↗
37. Residual strain in the rat left ventricle10.1161/01.RES.66.1.37 ↗
38. Transversely isotropic membrane shells with application to mitral valve mechanics. Constitutive modeling and finite element implementation10.1002/nme.1983 ↗
39. Finite element analysis of the mitral apparatus10.1007/s10237-007-0116-8 ↗
40. On shape finding methods and ultimate load analyses of reinforced concrete shells10.1016/0141-0296(91)90050-M ↗
41. In vivo dynamic strains of the ovine anterior mitral valve leaflet10.1016/j.jbiomech.2011.01.020 ↗
42. Characterization of mitral valve annular dynamics in the beating heart10.1007/s10439-011-0272-y ↗
43. Mitral valve annuloplasty—a quantitative clinical and mechanical comparison of different annuloplasty devices10.1007/s10439-011-0442-y ↗
44. Evidence of adaptive mitral leaflet growth10.1016/j.jmbbm.2012.07.001 ↗
45. Rausch, M.K., Famaey, N., O'Brien Shultz, T., Bothe, W., Miller, D.C., Kuhl, E. Mechanics of the mitral leaflet: a critical review, an in vivo parameter identification, and the effect of prestrain. Biomech. Model. Mechanobiol. 10.1007/s10237-012-0462-z, in press10.1007/s10237-012-0462-z ↗
46. In-vivo dynamic deformation of the mitral valve anterior leaflet10.1016/j.athoracsur.2006.03.117 ↗
47. Heart valve function10.1098/rstb.2007.2122 ↗
48. Modeling active muscle contraction in mitral valve leaflets during systole10.1007/s10237-010-0215-9 ↗
49. Stress-modulated growth, residual stress, and vascular heterogeneity10.1115/1.1412451 ↗
50. Timoshenko · 1953
51. On the effects of residual stress in microindentation tests of soft tissue structures10.1115/1.1695573 ↗