Polydopamine modified with Ag and CuO nanoparticles electrode for glucose sensor
Source abstract
Abstract
The major purpose of this work is to fabricate electrochemical glucose sensor by employing three electrodes of polydopamine (PDA), PDA-Ag nanoparticles (NPs) and PDA-Ag-CuO nanocomposites. Ag NPs were prepared using PDA as a reducing and stabilizing agent. The fabricated electrodes were evaluated in a phosphate buffer solution working as the electrolyte, spiked with varying concentrations of glucose ranged from 4 to 40 mM using cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). It was noted that Ag NPs and CuO NPs have face centered cubic and orthorhombic structures, respectively. Morphological studies displayed cauliflower shape for PDA, nanoluster spheres for Ag NPs and nanoneedles for CuO NPs ranged from 10 to 35 nm and 30 to 70 nm, respectively. The PDA-Ag NPs nanocomposite electrode exhibited a sensitivity of 1.0 × 10 −5 A·mM −1 , a correlation coefficient (R 2 ) of 96.5%, a limit of detection (LOD) of 1.73 mM, and a limit of quantification (LOQ) of 5.77 mM. It also demonstrated a relative standard deviation (RSD) of less than 1.5% and a repeatability of 1.6 × 10 −5 .PDA-Ag-CuO nanocomposite electrode achieved a sensitivity of 9.0 × 10 −6 A·mM −1 , with a strong linearity (R 2 = 99.2%), a calculated detection limit (LOD) of 1.08 mM, and a quantification limit (LOQ) of 3.60 mM. The relative standard deviation (RSD) was calculated to be below 3%, with a repeatability value of 2.8 × 10 −5 . The interference with glucose by ascorbic acid, urea, cholic acid, and dopamine was assessed, and the results indicated that PDA-Ag NPs-CuO nanocomposite electrode has a high selectivity to glucose.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Conducting polymers and applications · Advanced biosensing and bioanalysis techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Graduate Studies and Research
Alexandria University
Damanhur University
Heavy metal deparetment, Central Laboratory at Ministry of Health
References (57)
Show source-provided references
1. 10.1016/j.diabres.2017.03.02410.1016/j.diabres.2017.03.024 ↗
2. 10.1053/j.ackd.2014.03.00310.1053/j.ackd.2014.03.003 ↗
3. 10.3390/s1904080010.3390/s19040800 ↗
4. 10.3390/chemosensors1009036310.3390/chemosensors10090363 ↗
5. 10.1007/978-3-031-47180-3_1910.1007/978-3-031-47180-3_19 ↗
6. Salazar P, Martín M, González-Mora JL. Polydopamine-modified surfaces in biosensor applications. Polymer science: research advances, practical applications and educational aspects. Spain: Formatex Research Center SL, 2016, pp. 385–396.
7. 10.1039/D0SC04486E10.1039/D0SC04486E ↗
8. 10.1016/j.surfcoat.2018.01.00910.1016/j.surfcoat.2018.01.009 ↗
9. 10.3390/biomimetics303002610.3390/biomimetics3030026 ↗
10. 10.1155/2021/440182910.1155/2021/4401829 ↗
11. 10.1155/2021/668729010.1155/2021/6687290 ↗
12. Sagadevan S, Vennila S, Marlinda AR, et al. Synthesis and evaluation of the structural, optical, and antibacterial properties of copper oxide nanoparticles. Appl Phys A 2019; 125(8): 1–9.
13. Sharma S, Shukla S, Rastogi M. A review on biosensors and recent development. Acad An Int Multidiscip Res J 2021; 11(10): 613–620.
14. 10.1016/j.aca.2018.05.05110.1016/j.aca.2018.05.051 ↗
15. 10.1039/D2RA06789G10.1039/D2RA06789G ↗
16. 10.1016/j.talanta.2022.12390810.1016/j.talanta.2022.123908 ↗
17. 10.1016/j.snb.2018.03.08610.1016/j.snb.2018.03.086 ↗
18. 10.1016/j.aca.2020.03.03910.1016/j.aca.2020.03.039 ↗
19. 10.1016/j.colsurfa.2020.12481610.1016/j.colsurfa.2020.124816 ↗
20. 10.1007/s10570-020-03316-110.1007/s10570-020-03316-1 ↗
21. 10.1021/cr400407a10.1021/cr400407a ↗
22. 10.1038/s41598-021-95784-z10.1038/s41598-021-95784-z ↗
23. 10.1039/C4RA16469E10.1039/C4RA16469E ↗
24. 10.1088/2043-6262/ac458a10.1088/2043-6262/ac458a ↗
25. 10.1088/1757-899X/961/1/01201110.1088/1757-899X/961/1/012011 ↗
26. Zhu D, Wang L, Yu W, et al. Intriguingly high thermal conductivity increment for CuO nanowires contained nanofluids with low viscosity. Sci Rep 2018; 8(1): 1–12.
27. 10.1039/C6PY00356G10.1039/C6PY00356G ↗
28. 10.1038/s41598-021-95784-z10.1038/s41598-021-95784-z ↗
29. 10.3390/antibiotics1103035810.3390/antibiotics11030358 ↗
30. 10.3390/ma1421637910.3390/ma14216379 ↗
31. 10.1021/acsabm.1c0054810.1021/acsabm.1c00548 ↗
32. 10.1080/10826068.2018.147986410.1080/10826068.2018.1479864 ↗
33. 10.1016/j.est.2020.10163110.1016/j.est.2020.101631 ↗
34. 10.31788/RJC.2022.151657910.31788/RJC.2022.1516579 ↗
35. 10.1016/j.snb.2014.01.04610.1016/j.snb.2014.01.046 ↗
36. 10.1016/j.msec.2017.02.02610.1016/j.msec.2017.02.026 ↗
37. 10.1016/j.electacta.2021.13774410.1016/j.electacta.2021.137744 ↗
38. Alexandros C. Lazanas and Mamas I. ProdromidisACS. Measurement Science Au 2023; 3(3): 162–193.
39. 10.1016/j.colsurfa.2020.12481610.1016/j.colsurfa.2020.124816 ↗
40. Gijare M, Chaudhari S, Ekar S, et al. Reduced graphene oxide based electrochemical nonenzymatic human serum glucose sensor. ES Mater Manuf 2021; 14: 110–119.
41. 10.1016/j.colsurfa.2020.12481610.1016/j.colsurfa.2020.124816 ↗
42. Magnusson B. The fitness for purpose of analytical methods: a laboratory guide to method validation and related topics. 2014.
43. 10.1088/1361-6528/aa716410.1088/1361-6528/aa7164 ↗
44. 10.1039/D1DT02361F10.1039/D1DT02361F ↗
45. 10.1149/1945-7111/abd51510.1149/1945-7111/abd515 ↗
46. 10.1016/j.snb.2014.12.04410.1016/j.snb.2014.12.044 ↗
47. 10.1016/j.msec.2016.10.08010.1016/j.msec.2016.10.080 ↗
48. 10.1016/j.microc.2020.10575110.1016/j.microc.2020.105751 ↗
49. 10.1016/j.bej.2021.10812710.1016/j.bej.2021.108127 ↗
50. 10.1016/j.electacta.2020.13743410.1016/j.electacta.2020.137434 ↗
51. 10.3390/membranes1106038410.3390/membranes11060384 ↗
52. 10.1166/jnn.2018.1424310.1166/jnn.2018.14243 ↗
53. 10.1016/j.bej.2021.10812710.1016/j.bej.2021.108127 ↗
54. 10.1007/s00216-021-03447-910.1007/s00216-021-03447-9 ↗
55. 10.1016/j.snb.2018.03.08610.1016/j.snb.2018.03.086 ↗
56. 10.1016/j.aca.2020.03.03910.1016/j.aca.2020.03.039 ↗
57. 10.1016/j.colsurfa.2020.12481610.1016/j.colsurfa.2020.124816 ↗