journal article·2010-11

Measuring visual fatigue and visual discomfort associated with 3‐D displays

Marc Lambooij, Marten Fortuin, Wijnand Ijsselsteijn, Bruce Evans, Ingrid Heynderickx

Publisher page

Abstract

Abstract— This research identifies methods for signs of visual complaints associated with stereoscopic displays. Two potential causes for contradictory results concerning these signs in previous research are hypothesized: (1) not all clinical tests are equally appropriate and (2) there is a natural variation in susceptibility amongst people with normal vision. An optometric screening differentiated participants with moderate binocular status (MBS) from those with good binocular status (GBS). In a 2 × 2 within‐subjects design (2‐D vs. 3‐D and MBS vs. GBS), a questionnaire and eight optometric tests (i.e., binocular acuity, aligning prism, fixation disparity, heterophoria, convergent and divergent fusional reserves, vergence facility, and accommodation response) were each administered before and immediately after a reading task. Results revealed that only participants with MBS in 3‐D conditions showed clinically meaningful changes in fusion range, experienced more visual discomfort, and performed worse on the reading task. Acombination of fusion range measurements and self‐report is appropriate for evaluating visual complaints of stereoscopic stills, and people with a MBS are more susceptible to visual complaints associated with stereoscopic displays. A simple measurement tool, i.e., the ratio of reading performance between 2‐D and 3‐D, to categorize people based on their binocular status is proposed.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Visual perception and processing mechanisms · Ophthalmology and Visual Impairment Studies · Tactile and Sensory Interactions

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (42)

Show source-provided references
1. 10.2352/J.ImagingSci.Technol.2009.53.3.03020110.2352/J.ImagingSci.Technol.2009.53.3.030201 ↗
2. 10.1889/JSID18.6.40510.1889/JSID18.6.405 ↗
3. 10.1889/JSID17.5.45910.1889/JSID17.5.459 ↗
4. I.Heynderickx “Performance evaluation of 2‐D and 3‐D TV‐systems ”Proc. ICIS374 (2006).
5. 10.1109/TCSVT.2004.82339810.1109/TCSVT.2004.823398 ↗
6. 10.1167/8.3.3310.1167/8.3.33 ↗
7. 10.1016/S0042-6989(97)00397-010.1016/S0042-6989(97)00397-0 ↗
8. F.Speranzaet al. “Effect of disparity and motion on visual comfort of stereoscopic images ”Proc. SPIE6055 (2006).10.1117/12.640865 ↗
9. 10.1016/j.displa.2004.09.00210.1016/j.displa.2004.09.002 ↗
10. 10.1889/1.198494810.1889/1.1984948 ↗
11. 10.5594/J0165610.5594/J01656 ↗
12. 10.1016/j.displa.2004.07.00110.1016/j.displa.2004.07.001 ↗
13. 10.1016/j.displa.2008.11.00110.1016/j.displa.2008.11.001 ↗
14. 10.1109/JDT.2005.85893810.1109/JDT.2005.858938 ↗
15. 10.1097/00006324-193410000-0000110.1097/00006324-193410000-00001 ↗
16. 10.1007/BF0232476510.1007/BF02324765 ↗
17. 10.1016/0042-6989(84)90038-510.1016/0042-6989(84)90038-5 ↗
18. 10.1046/j.1475-1313.1997.97000379.x10.1046/j.1475-1313.1997.97000379.x ↗
19. 10.1111/j.1475-1313.2006.00385.x10.1111/j.1475-1313.2006.00385.x ↗
20. “A survey of the prevalence of binocular % accommodative dysfunctions in a sample of optometry students
21. “The scientific basis for and efficacy of optometric vision therapy in nonstrabismic accommodative and vergence disorders
22. “Accommodative and binocular vision disorders associated with video display terminals: diagnosis and management issues
23. B.J. W.Evans Pickwell's Binocular Vision Anomalies: Investigation and Treatment 5th edn. (Butterworth‐Heinemann London UK 2007).10.1016/B978-0-7506-8897-0.50004-4 ↗
24. 10.1136/bjo.2007.13470010.1136/bjo.2007.134700 ↗
25. 10.1097/00006324-200312000-0001410.1097/00006324-200312000-00014 ↗
26. 10.1001/archopht.118.5.61510.1001/archopht.118.5.615 ↗
27. 10.1001/archopht.119.7.105010.1001/archopht.119.7.1050 ↗
28. 10.1097/00006324-200311000-0000810.1097/00006324-200311000-00008 ↗
29. B.J. W.Evans Pickwell's Binocular Vision Anomalies 3rd edn. (Butterworth‐Heinemann Oxford 1997).
30. M. F.Fortuinet al. “An exploration of the effects of stereoscopic displays on optometric parameters and asthenopic symptoms ”J. Ophthal. Physiol. Opt.(to be published).
31. 10.1097/00006324-199810000-0001710.1097/00006324-199810000-00017 ↗
32. 10.1016/S0141-9382(96)01040-210.1016/S0141-9382(96)01040-2 ↗
33. 10.1046/j.1475-1313.1996.96000282.x10.1046/j.1475-1313.1996.96000282.x ↗
34. 10.1046/j.1475-1313.2002.00079.x10.1046/j.1475-1313.2002.00079.x ↗
35. 10.1111/j.2044-8295.1997.tb02656.x10.1111/j.2044-8295.1997.tb02656.x ↗
36. 10.1111/j.1467-9817.2005.00274.x10.1111/j.1467-9817.2005.00274.x ↗
37. 10.1111/j.1475-1313.2006.00400.x10.1111/j.1475-1313.2006.00400.x ↗
38. M.Millodot Dictionary of Optometry 7th edn.(Butterworth‐Heinemann Oxford 2009).
39. J. F.Hairet al. Multivariate Data Analysis(Pearson Prentice‐Hall New York 2006).
40. 10.1117/12.27445610.1117/12.274456 ↗
41. M.Lambooijet al. “Measuring visual discomfort associated with 3‐D displays ”Proc. SPIE7237‐21 (2009b).10.1117/2.1200905.1653 ↗
42. F. L.vanNes“Visually representing reality; aesthetics and accessibility aspects ”Proc. SPIE7240 (2009).10.1117/12.805847 ↗