Image formation modeling and analysis of near‐eye light field displays
Source abstract
Abstract
Abstract Near‐eye light field displays based on integral imaging through a microlens array provide attractive features like ultra‐compact volume and freedom of the vergence‐accommodation conflict to head‐mounted displays with virtual or augmented reality functions. To enable optimal design and analysis of such systems, it is desirable to have a physical model that incorporates all factors that affect the image formation, including diffraction, aberration, defocusing, and pixel size. Therefore, in this study, using the fundamental Huygens‐Fresnel principle and the Arizona eye model with adjustable accommodation, we develop an image formation model that can numerically calculate the retinal light field image with near‐perfect accuracy, and experimentally verify it with a prototype system. Next, based on this model, the visual resolution is analyzed for different field of views (FOVs). As a result, a rapid resolution decay with respect to FOV caused by off‐axis aberration is demonstrated. Finally, resolution variations as a function of image depth are analyzed based on systems with different central depth planes. Significantly, the resolution decay is revealed to plateau when the image depth is large enough, which is different from real‐image type light field displays.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Optical Imaging Technologies · Virtual Reality Applications and Impacts · Visual perception and processing mechanisms
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Photonics National Chiao Tung University Hsinchu 300 Taiwan
Display R&D for Daydream Google LLC Mountain View 94043 California
Funding
Ministry of Science and Technology, Taiwan
References (43)
Show source-provided references
1. Advances in three‐dimensional integral imaging: Sensing, display, and applications10.1364/AO.52.000546 ↗
2. “An 18 megapixel 4.3” 1443 ppi 120 Hz OLED display for wide field of view high acuity head mounted displays
3. Advances in virtual, augmented, and mixed reality technologies
4. Fundamentals of 3D imaging and displays: A tutorial on integral imaging, light‐field, and plenoptic systems10.1364/AOP.10.000512 ↗
5. Design of an optical see‐through head‐mounted display with a low f‐number and large field of view using a freeform prism10.1364/AO.48.002655 ↗
6. High dynamic range head mounted display based on dual‐layer spatial modulation10.1364/OE.25.023320 ↗
7. Design and fabrication of an off‐axis see‐through head‐mounted display with an x–y polynomial surface10.1364/AO.49.003661 ↗
8. Design of a large field‐of‐view see‐through near to eye display with two geometrical waveguides10.1364/OL.41.005426 ↗
9. Polarization volume grating with high efficiency and large diffraction angle10.1364/OE.24.017746 ↗
10. Diffraction efficiency distribution of output grating in holographic waveguide display system10.1109/JPHOT.2018.2856774 ↗
11. Characterization and optimization of field of view in a holographic waveguide display10.1109/JPHOT.2017.2767606 ↗
12. 51‐5: Lightguide with stair micromirror structure for augmented reality glasses10.1002/sdtp.11743 ↗
13. Enabling focus cues in head‐mounted displays10.1109/JPROC.2017.2648796 ↗
14. Perceivable light fields: Matching the requirements between the human visual system and autostereoscopic 3‐D displays10.1109/JPROC.2014.2348938 ↗
15. Projection‐type see‐through holographic three‐dimensional display10.1038/ncomms12954 ↗
16. P‐226L: Late‐news poster the optical design of head‐mounted display system based on computer generated holography10.1002/sdtp.11960 ↗
17. 7‐1: Computer generated hologram accelerated by using hybrid iterative Fourier transform algorithm (HIFTA) on phase modulator LCOS10.1002/sdtp.12559 ↗
18. Systematic characterization and optimization of 3D light field displays10.1364/OE.25.018508 ↗
19. Light‐field imaging and display systems
20. Hybrid light field head‐mounted display using time‐multiplexed liquid crystal lens array for resolution enhancement10.1364/OE.27.001164 ↗
21. Near‐eye light field displays10.1145/2508363.2508366 ↗
22. The light field stereoscope: Immersive computer graphics via factored near‐eye light field displays with focus cues
23. Slim near‐eye display using pinhole aperture arrays10.1364/AO.54.003422 ↗
24. Tensor displays
25. Optimal projector configuration design for 300‐Mpixel multi‐projection 3D display10.1364/OE.21.026820 ↗
26. Analysis of resolution limitation of integral photography10.1364/JOSAA.15.002059 ↗
27. Analysis of the depth of field of integral imaging displays based on wave optics10.1364/OE.21.031263 ↗
28. Image formation analysis and high resolution image reconstruction for plenoptic imaging systems10.1364/AO.52.000D22 ↗
29. P‐91: Light field display simulator for experience and quality evaluation10.1002/sdtp.12268 ↗
30. Wavefront aberration correction for integral imaging with the pre‐filtering function array10.1364/OE.26.027064 ↗
31. P‐94: Free‐form micro‐optical design for enhancing image quality (MTF) at large FOV in light field near eye display10.1002/sdtp.12273 ↗
32. Resolution enhanced light field near eye display using e‐shifting method with birefringent plate10.1002/jsid.665 ↗
33. Long working range light field microscope with fast scanning multifocal liquid crystal microlens array10.1364/OE.26.010981 ↗
34. Integral imaging based light field display with enhanced viewing resolution using holographic diffuser10.1016/j.optcom.2017.06.061 ↗
35. Wide‐viewing integral imaging system using polarizers and light barriers array10.1186/s41476-017-0052-x ↗
36. Born M · 2013
37. SchwiegerlingJ.Field guide to visual and ophthalmic optics SPIE.2004.10.1117/3.592975 ↗
38. ZemaxLLC Zemax OpticStudio 18.7 User Manual. 2018.
39. Directional sensitivity of the retina: 75 years of Stiles‐Crawford effect10.1098/rspb.2008.0712 ↗
40. Contrast‐sensitivity‐based evaluation method of a surveillance camera's visual resolution: Improvement from the conventional slanted‐edge spatial frequency response method10.1364/AO.56.001464 ↗
41. Dual layer electrode liquid crystal lens for 2D/3D tunable endoscopy imaging system10.1364/OE.24.008527 ↗
42. High‐resistance liquid‐crystal lens array for rotatable 2D/3D autostereoscopic display10.1364/OE.22.002714 ↗
43. Hybrid computational near‐eye light field display10.1109/JPHOT.2019.2893934 ↗