journal article·2009-11

Effect of gas pressure on permanent dark image sticking on a bright screen in AC plasma‐display panels

Choon‐Sang Park, Soo‐Kwan Jang, Heung‐Sik Tae, Eun‐Young Jung, Jeong‐Chull Ahn

Publisher page

Abstract

Abstract— The permanent dark‐image‐sticking phenomenon on a bright screen was examined under various gas pressures in a 42‐in. ACPDP with an He(35%)‐Xe(11%)‐Ne gas composition. Infrared‐emission observations reveal that the discharge characteristics related to the MgO surface are almost the same in both the discharge and non‐discharge cells, whereas luminance observations show a deterioration in the visible‐conversion characteristics related to the phosphor layer in both the discharge and non‐discharge cells. Consequently, the permanent dark‐image‐sticking phenomenon on a bright screen is found to be strongly related to the deposition on the phosphor layer to the Mg species sputtered from the MgO surface due to a repetitive strong sustain discharge. For a decrease in gas pressure, the permanent dark image sticking on a bright screen became worse due to a severe degradation of the visible‐conversion characteristics of the phosphor layer caused by the deposition of higher amounts of sputtered Mg species on the phosphor layer, as confirmed by various measurements, such as Vt closed curves, time‐of‐flight secondary‐ion mass spectrometry, photoluminescence, and atomic‐force‐microscope analyses.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ion-surface interactions and analysis · Diamond and Carbon-based Materials Research · Thin-Film Transistor Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (8)

Show source-provided references
1. H.‐S.Taeet al. “Driving waveform for reducing temporal dark image sticking in AC plasma display panel based on perceived luminance ”IEEE Trans. Plasma Sci. 996–1003(2006).10.1109/TPS.2006.875828 ↗
2. T.Kosakaet al.“Firing voltage fluctuation phenomenon caused by gas density nonuniformity in PDPs ”IDW Symposium Digest '05 1469–1472(2005).
3. 10.1889/1.306949110.1889/1.3069491 ↗
4. L. C.Pitchfordet al. “Ion and neutral energy distribution to the MgO surface and sputtering rates in plasma display panel cells ”IEEE Trans. Plasma Sci. 351–359(2006).10.1109/TPS.2006.872426 ↗
5. C.‐S.Parket al. “Experimental observation of halo‐type boundary image sticking in AC plasma display panel ”IEEE Trans. Electron Dev. 1315–1320(2007).10.1109/TED.2007.896578 ↗
6. C.‐S.Parket al. “Recovery of boundary image sticking using aging discharge in AC plasma display panel ”IEEE Trans. Plasma Sci. 1511–1517(2007).10.1109/TPS.2007.905208 ↗
7. C.‐S.Parket al. “Prevention of boundary image sticking in AC plasma display panel using vacuum sealing process ”IEEE Trans. Electron Dev. 1345–1351(2008).10.1109/TED.2008.921986 ↗
8. “Role of redeposition of sputtered Mg particles in image sticking”