Lifetime prediction model of electrophoretic display based on high temperature and high humidity test
Source abstract
Abstract
Abstract This paper studied the failure model of electrophoretic display (EPD) under different temperature and humidity conditions. With nine high temperature and high humidity tests, it verified that the Arrhenius accelerated lifetime model and the Peck accelerated lifetime model were not suitable for the lifetime prediction of EPD. Therefore, based on these two accelerated life models, this article proposed a new acceleration lifetime model, the Luo, Wu and Wu (LWW) model, which was more suitable for EPDs.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrowetting and Microfluidic Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Guangzhou OED Technologies Inc. Guangzhou Guangdong 511458 China
Funding
Research and Industrialization of Key Technologies for Flexible Organic TFT and Flexible Electrophoretic Display
References (12)
Show source-provided references
1. 10.2528/PIER1312040510.2528/PIER13120405 ↗
2. 10.1889/1.220610610.1889/1.2206106 ↗
3. 10.1002/sdtp.1252110.1002/sdtp.12521 ↗
4. Review: reflective displays and E‐paper
5. French I · 100
6. CarusoH Dasgupta A.A fundamental overview of accelerated testing analytical models. Proceedings Annual Reliability and Maintainability Symposium 1998 pp.389‐393.10.1109/RAMS.1998.653809 ↗
7. Accelerated life testing on repairable systems
8. Research to the hygrothermal ageing characteristic of solid rocket motor (SRM) adhint
9. Research of accelerated life testing technology application at home and abroad
10. GJB1407‐92:Reliability growth test. COSTIND 1992.
11. IEC 62679‐4‐2 Ed.1:Electronic paper displays—Part 4‐2: environmental test method. IEC technical committee 2015.
12. Seppanen O · 2009