Visual comfort in autostereoscopic display
Source abstract
Abstract
Abstract Autostereoscopic displays are likely to become widely used products in the future. However, certain physiological factors, especially visual comfort, limit their development. In this study, four observational parameters – ambient illuminance, image content, scaling ratio, and horizontal distance between major and minor objects – were evaluated to determine the degree of visual comfort offered by 3D computer‐generated images on an autostereoscopic display. Visual comfort score with the range of 0–1 is designed to represent the degree of visual comfort for the 3D images with different manipulations of ambient illuminance, image content, scaling ratio, and horizontal distance between major and minor objects in this study. Subjects were asked to indicate images that produced discomfort. The proportion of images for each condition where participants indicated that viewing the image was comfortable was computed. Images receiving a proportion of 0.5 or greater were classified as acceptable. The disparity ranges over which acceptable images were attained for each participant and for each condition were analyzed with analysis of variance. The analytical results indicate that ambient illuminance and image content have a significant effect on the acceptable disparity range, while scaling ratio and horizontal distance between major and minor objects did not.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Optical Imaging Technologies · Virtual Reality Applications and Impacts · Visual perception and processing mechanisms
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Graduate Institute of Electro‐Optical Engineering National Taiwan University of Science and Technology Taipei Taiwan
Graduate Institute of Color and Illumination Technology National Taiwan University of Science and Technology Taipei Taiwan
Graduate Institute of Applied Science and Technology National Taiwan University of Science and Technology Taipei Taiwan
References (20)
Show source-provided references
1. 10.1016/S0141-9382(96)01040-210.1016/S0141-9382(96)01040-2 ↗
2. Three‐dimensional displays: a review and applications analysis
3. 10.2352/J.ImagingSci.Technol.2009.53.3.03020110.2352/J.ImagingSci.Technol.2009.53.3.030201 ↗
4. 10.1016/j.displa.2004.07.00410.1016/j.displa.2004.07.004 ↗
5. 10.1889/JSID17.12.98710.1889/JSID17.12.987 ↗
6. 10.1080/10803548.1999.1107643810.1080/10803548.1999.11076438 ↗
7. 10.2352/J.ImagingSci.Technol.2011.55.1.01050210.2352/J.ImagingSci.Technol.2011.55.1.010502 ↗
8. 10.1016/j.displa.2011.02.00310.1016/j.displa.2011.02.003 ↗
9. The effect of stereoscopic display luminance and ambient illuminance on physiological measurement and image quality
10. 10.1002/jsid.14610.1002/jsid.146 ↗
11. 10.1117/12.87234710.1117/12.872347 ↗
12. Effect of disparity and motion on visual comfort of stereoscopic images
13. The comfort zone and fusion limit of a foreground object with its background on a large format 3D Display
14. 10.1117/12.47414610.1117/12.474146 ↗
15. 10.1117/12.52201810.1117/12.522018 ↗
16. Parallax distribution and visual comfort in stereoscopic images
17. 10.1117/12.87253010.1117/12.872530 ↗
18. 3D consortium “3DC safety guidelines for dissemination of human‐friendly 3D ” 3D Consortium (3DC) Safety/Guidelines Section (2010).
19. 10.1117/1.JEI.23.4.04301410.1117/1.JEI.23.4.043014 ↗
20. “Information and guidelines for assessing and minimizing visual discomfort and visual fatigue from 3D video ” Recommendation ITU‐T P.916 (03/2016).