journal article·2008-09

Measurement of human visual perception for Mura with some features

Chun‐Chih Chen, Sheue‐Ling Hwang, Chao‐Hua Wen

Publisher page

Abstract

Abstract— The defects of flat‐panel liquid‐crystal display are usually not uniform, and the defects are called as “Mura.” There are many factors that cause the Mura phenomenon. At present, the human eyes define the seriousness of Mura, and different operators define the same Mura phenomenon with different meanings. For this reason, there have been many conflicts between the suppliers of flat‐panel liquid‐crystal display and customers. In order to solve the conflicts between the suppliers and customers, some researchers proposed a regression equation for the luminance contrast threshold and the size of Mura. In addition to the effect of Mura size on luminance contrast threshold, this study investigated the relationship between other factors and luminance contrast threshold. An analysis of the results show that Mura size, polarity of Mura, Mura position, and different color backgrounds significantly affect the visual contrast threshold. However, polarity did not significantly affect visual contrast threshold. In this study, it was found that Mura size was more important than the other factors for visual contrast threshold. The results of this study is expected to be referenced for inspection by the LCD industry.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Visual perception and processing mechanisms · Surface Roughness and Optical Measurements · Color Science and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. “Reading from microfiche, a VDT, and the printed page: subjective fatigue and performance,”10.1177/001872088602800107 ↗
2. 10.1080/0014013920896739410.1080/00140139208967394 ↗
3. “Characterizations of viewing‐angle‐dependent colorimetric and photometric performance of color LCDs,”
4. “Visibility of transmissive liquid crystal displays under dynamic lighting conditions,”10.1177/001872089203400508 ↗
5. D. G.Lee I. H.Kim M. C.Jeong B. K.Oh andW. Y.Kim “Mura analysis method by using JND luminance and the SEMU definition ”Proc. IDW '03 1467–1470(2003).
6. 10.1364/JOSA.33.00001810.1364/JOSA.33.000018 ↗
7. 10.1117/12.40585610.1117/12.405856 ↗
8. 10.3169/itej.56.183710.3169/itej.56.1837 ↗
9. 10.1113/jphysiol.1985.sp01559110.1113/jphysiol.1985.sp015591 ↗
10. 10.1016/S0042-6989(01)00056-610.1016/S0042-6989(01)00056-6 ↗
11. W. K.PrattandS. S.Sawkar “Method and apparatus for detecting mura defects ”U.S. Patent 6 154 561 (2000).
12. 10.1117/12.30123210.1117/12.301232 ↗
13. 10.1080/1044731930952607110.1080/10447319309526071 ↗
14. SEMI Draft Document 3324(2002).
15. SEMI Definition of measurement index (SEMU) for luminance Mura in FPD image quality inspection. SEMI D31‐1102 (2002).
16. 10.1016/S0169-8141(96)00026-110.1016/S0169-8141(96)00026-1 ↗
17. H. L.Snyder J. J.Decker J. C.Lloyd andC.Dye “Effect of image polarity on VDT task performance ”Proc. Human Factors Society 34th Annual Meeting Santa Monica CA 1447–1451(1990).10.1177/154193129003401906 ↗
18. T.Tamura M.Baba andT.Furuhata “Effect of the background luminance on just noticeable difference (JND) contrast of “Mura” in LCDs ”Proc. IDW '03 1527–1530(2003).
19. T.Tamura K.Tanaka M.Baba M.Suzuki andT.Furuhata “Just noticeable difference (JND) contrast of “Mura” in LCDs on the five background luminance levels ”Proc. IDW '04 1623–1626(2004).
20. 10.1093/ietele/e89-c.10.143510.1093/ietele/e89-c.10.1435 ↗
21. VESA 330‐x Mura Defects Vesa_mura_11.frm Jan. 24 1–15 (2000).
22. VESA Standards Flat Panel Display Measurements (FPDM2) Version 2.0 VESA‐2001‐6 p.78(2001).
23. 10.1016/S0169-8141(99)00040-210.1016/S0169-8141(99)00040-2 ↗
24. 10.3758/BF0320282810.3758/BF03202828 ↗
25. Wyszecki G. · 1982
26. 10.1177/00187208900320010410.1177/001872089003200104 ↗
27. 10.1080/0014013900892530010.1080/00140139008925300 ↗