Using the human observer to assess medical image display quality
Source abstract
Abstract
Abstract— Image quality is an important component in the evaluation of medical imaging systems and can be measured at a number of points between acquisition and display. However, from the perspective of the clinician, the quality of the image that is presented to the eye‐brain system is the most critical since this is what the diagnostic interpretation is derived from. This paper will discuss some ways to assess the design and optimization of display systems in reference to the human observer. The paper will include various approaches to study this issue, including Receiver Operating Characteristic studies, modeling of the human‐visual system, and the use of eye‐position tracking methods. The goal is to demonstrate not only the importance of assessing the impact of display image quality on diagnostic performance, but also on how it can affect workflow and user‐comfort levels.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Digital Radiography and Breast Imaging · Advanced X-ray and CT Imaging · Medical Imaging Techniques and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. 10.1089/1530562025293337410.1089/15305620252933374 ↗
2. 10.1016/S0001-2998(78)80014-210.1016/S0001-2998(78)80014-2 ↗
3. 10.1097/00004424-199209000-0001510.1097/00004424-199209000-00015 ↗
4. “Unified measurement of observer performance in detecting and localizing target objects on images
5. “Observer studies involving detection and localization: Modeling, analysis, and validation
6. 10.1016/S1076-6332(03)80164-210.1016/S1076-6332(03)80164-2 ↗
7. 10.1109/TMI.2004.82835810.1109/TMI.2004.828358 ↗
8. 10.1016/S1076-6332(97)80013-X10.1016/S1076-6332(97)80013-X ↗
9. 10.1016/S1076-6332(97)80210-310.1016/S1076-6332(97)80210-3 ↗
10. 10.1016/S1076-6332(03)80560-310.1016/S1076-6332(03)80560-3 ↗
11. http:perceptionradiology uiowa eduDefault aspxtabid120(Last accessed 3‐6‐06).
12. http:xraybsd uchicago edukrlroc_soft htm(Last accessed 3‐6‐06).
13. C.E.Metz “Receiver Operating Characteristic (ROC) Analysis: A tool for quantitative evaluation of observer performance and imaging systems ”JACR(to be published).
14. 10.1089/10783029931200510.1089/107830299312005 ↗
15. 10.1016/j.humpath.2004.09.00210.1016/j.humpath.2004.09.002 ↗
16. 10.1117/12.23779410.1117/12.237794 ↗
17. 10.1117/12.27131210.1117/12.271312 ↗
18. J.Lubin “A visual system discrimination model for imaging system design and evaluation ” in:Visual Models for Target Detection and Recognition ed. E. Peli (World Scientific Publishers Hackensack NJ 1995) pp 245–283.10.1142/9789812831200_0010 ↗
19. J.Lubin M.H.Brill andR.L.Crane “Vision model‐based assessment of distortion magnitudes in digital video ” paper presented at IAB Made to Measure Technical Seminar Montreux Switzerland 1996.
20. 10.1016/S1076-6332(03)80040-510.1016/S1076-6332(03)80040-5 ↗
21. 10.1016/S1076-6332(03)00293-910.1016/S1076-6332(03)00293-9 ↗
22. 10.1117/12.48034010.1117/12.480340 ↗
23. 10.1007/s10278-004-1016-410.1007/s10278-004-1016-4 ↗
24. 10.1016/j.acra.2005.04.01510.1016/j.acra.2005.04.015 ↗
25. E.A.Krupinski “Medical image perception and large image datasets in the digital reading room ” in:Decision Support in the Digital Medical Enterprise ed. B.I. Reiner E.L. Siegel and B. J. Erickson (SCAR Publications Great Falls VA 2005) pp.105–120.
26. 10.1016/S1076-6332(99)80191-310.1016/S1076-6332(99)80191-3 ↗
27. 10.1016/S1076-6332(03)80308-210.1016/S1076-6332(03)80308-2 ↗