A pretreatment to improve the quality metrics performance for encoding H264/AVC
Source abstract
Abstract
Abstract The study of the human visual system is very interesting to quantify the quality of an image or to predict perceived information. The contrast sensitivity function is one of the main ways to incorporate the human visual system properties in an imaging system. It characterizes its sensitivity to spatial frequencies. In this paper, we are interested in establishing a pretreatment for existing metrics with full reference (“peak signal‐to‐noise ratio”, “digital video quality”) for the H.264/MPEG‐4 (Motion Picture Expert Group) advanced video coding standard. We realize in our algorithm the FFT transformation to apply the contrast sensitivity function. Our method is applicable to any size of image and video sequence by increasing its size at powers of two. This increase is achieved by adding “mirror image.” We evaluate the performance of the proposed pretreatment by using subjective “LIVE” video databases. The performance metrics, that is, Pearson (PLCC), Spearman correlation coefficients (SROCC) and root mean square prediction error (RMSE) indicate that the proposed method gives a good performance in H264 codec distortions.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Image and Video Quality Assessment · Video Coding and Compression Technologies · Advanced Image Processing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Laboratory of Electronics and Information Technologies, National School of Engineering Sfax University of Sfax Sfax Tunisia
References (40)
Show source-provided references
1. Girod B. · 1993 · 207
2. 10.1109/TIP.2003.81986110.1109/TIP.2003.819861 ↗
3. Z.Wang et al. Multiscale structural similarity image quality assessment. Conference Record of the Thirty‐Seventh Asilomar Conference 2 1398–1402(2003).
4. 10.1109/TIP.2007.90182010.1109/TIP.2007.901820 ↗
5. 10.1109/TIP.2005.85937810.1109/TIP.2005.859378 ↗
6. 10.1109/TIP.2009.203499210.1109/TIP.2009.2034992 ↗
7. 10.1016/S0923-5965(03)00076-610.1016/S0923-5965(03)00076-6 ↗
8. 10.1109/TBC.2004.83402810.1109/TBC.2004.834028 ↗
9. 10.1117/1.132989610.1117/1.1329896 ↗
10. 10.1109/JSTSP.2009.201449710.1109/JSTSP.2009.2014497 ↗
11. Wolf S. · 2005
12. 10.1007/s11042-010-0473-710.1007/s11042-010-0473-7 ↗
13. 10.1109/TNN.2006.87976610.1109/TNN.2006.879766 ↗
14. 10.1109/TCSVT.2010.208745610.1109/TCSVT.2010.2087456 ↗
15. 10.1109/TIP.2005.86416510.1109/TIP.2005.864165 ↗
16. Reduced‐reference image quality assessment in reorganized DCT domain
17. 10.1109/TIP.2008.201176010.1109/TIP.2008.2011760 ↗
18. N. D.NarvekarandL. J.Karam A no‐reference perceptual image sharpness metric based on a cumulative probability of blur detection in IEEE International Workshop on Quality of Multimedia Experience San Diego CA (2009) pp.87–91.10.1109/QOMEX.2009.5246972 ↗
19. S.VaradarajanandL. J.Karam An improved perception‐based no reference objective image sharpness metric using iterative edge refinement in IEEE International Conference on Image Processing San Diego CA (2008) pp.401–404.10.1109/ICIP.2008.4711776 ↗
20. N. G.Sadaka et al. A no reference perceptual image sharpness metric based on saliency‐weighted foveal pooling in IEEE International Conference on Image Processing San Diego CA (2008) pp.369–372.10.1109/ICIP.2008.4711768 ↗
21. 10.1109/TIP.2005.85449210.1109/TIP.2005.854492 ↗
22. Chen J. · 2008 · 894
23. 10.1016/j.sigpro.2009.02.00710.1016/j.sigpro.2009.02.007 ↗
24. A perceptual measure of blocking artifact for no reference video quality evaluation for H.264 codec
25. FengXiao DCT‐based video quality evaluation MSU Graphics and Media Lab (Video Group) winter (2000).
26. Toward a perceptual video quality metric
27. 10.1109/TIT.1974.105525010.1109/TIT.1974.1055250 ↗
28. 10.1109/TCOM.1985.109633710.1109/TCOM.1985.1096337 ↗
29. K.Ngan et al. Cosine transform coding incorporating human visual system model; presented at SPIE fiber' 86 (1986).10.1117/12.937262 ↗
30. Designing quantization table for Hadamard transform based on human visual system for image compression
31. M.Ben Amor et al. Exploitation des caractéristiques du système visuel humain dans les métriques de qualité Cinquième workshop AMINA (2010) pp123–130.
32. V.Rosselli et al. Métrique de différence couleur basée sur le seuil de perception» on COROSA COmpression et REprésentation des Signaux Audiovisuels Montpellier (2007) pp. 8–9.
33. A.Stoica et al. Amélioration de la qualité visuelle d' images couleur dans le cadre du standard de compression JPEG2000 traitement du signal 2004_volume 21_numéro spécial L'image numérique couleur(2004).
34. Oppenheim A. V. · 1998
35. R.Szeliski.Computer vision: algorithms and applications. Springer Science & Business Media.2010.10.1007/978-1-84882-935-0 ↗
36. Technical University of Munich [Online]; Available:ftp://ftp.ldv.e‐technik.tu‐muenchen.de/pub/test sequences/
37. 10.1109/TIP.2010.204211110.1109/TIP.2010.2042111 ↗
38. K.Seshadrinathan et al. A subjective study to evaluate video quality assessment algorithms. SPIE Proceedings Human Vision and Electronic Imaging Jan. 2010.10.1117/12.845382 ↗
39. URL:http://live.ece.utexas.edu/research/quality/live_video.html.
40. 10.1109/TIP.2006.88195910.1109/TIP.2006.881959 ↗