journal article·2012-11

Character‐contrast measurements on emissive displays using replica masks under uniform ambient illumination

Edward F. Kelley, Caesar Eghtesadi, Morgan Blubaugh, William Reuschel

Publisher page

Abstract

Abstract A replica‐mask method is presented to measure the contrast of character strokes on emissive displays under carefully controlled illumination. The method accounts for veiling glare introduced into the detector by the bright areas surrounding the dark characters. A sampling sphere is used to provide a uniform diffuse surround. Measurements of the diffuse reflectances are provided with specular included and with specular excluded. For emissive displays, the contrast depends both upon the darkroom characteristics of the emissive display and its reflective characteristics. Details are provided to replicate the measurement procedure.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Visual perception and processing mechanisms · Color Science and Applications · Optical measurement and interference techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

KELTEK LLC Longmont CO 80503 USA

Tech For All, Inc. Royal Palm Beach FL 33421 USA

American Foundation for the Blind Huntington WV 25701 USA

References (18)

Show source-provided references
1. 10.1889/JSID19.10.68510.1889/JSID19.10.685 ↗
2. “Military Standard Photographic Lenses ” MIL‐STD‐150A 12 May 1959 superseding MIL‐STD‐150 of 23 October 1950. See 3.6.10 Veiling Glare under Optical Characteristics (§ 3.6) and 5.1.2.19 Veiling Glare under Methods of Test and Measurement (§ 5.1).
3. P. L.Pryor “The three primary parameters of imaging systems and detective quantum efficiency ” Air Force Avionics Laboratory Wright‐Patterson Air Force Base Technical Report AFAL‐TR‐73‐37 (May1973).
4. L.deVismeandL.Agesen “Contrast and luminance measurements on work places with CRT display terminal ” Application Notes Brüel & Kjær Instruments pp. 24.
5. Grandjean É. · 1987
6. B.Andrénet al. “A comparison of visual ergonomic measurements between active and passive 3DTV ” EuroDisplay Soc. for Info. Display paper 109 (2011).
7. A.Czajkowski “Controlling veiling glare in an optical imaging system ” OPT523L final report College of Optical Sciences University of Arizona (May 15 2009).
8. E. F.Kelley “Simulated‐eye‐design camera for high‐contrast measurements ” International Society for Optical Engineering (SPIE) Electronic Imaging Conference San Jose CA (January 29 1999) Proceedings of SPIE Flat Panel Display Technology and Display Metrology Vol. 3636 pp.184–190.10.1117/12.344645 ↗
9. See §11.11 Ambient Character‐Stroke Contrast and in the appendix A2.1.6 Correcting for Glare with Replica Masks Information Display Measurements Standard(IDMS) version 1.03 International Committee for Display Metrology (ICDM) Society for Information Display (SID) (June2012).
10. Disclaimer: The apparatus described or shown in this document are identified only for the purpose of complete technical description or illustration. Because a number of different devices can be used to provide similar results the author is not recommending that these devices are the only ones that should or can be used. The camera used is a Canon EOS Rebel T2i with an 18–55 mm or 75–300 mm zoom lens. The software used to control the camera and collect the data is MaxIm DL. The spectroradiometer used to measure the reflectances is a Photo Research PR‐730.
11. Standards generally recommend using from 10 to 20 cpx per display pixel when array detectors are used (cameras) and we generally like to exceed that. However we were unable to achieve this because of the small size of the pixels on the selected display. See for example 7.1 Line Luminance and Contrast Information Display Measurements Standard(IDMS) version 1.03 International Committee for Display Metrology (ICDM) Society for Information Display (SID) (June 2012).
12. P. A.BoyntonandE. F.Kelley “Small‐Area Black Luminance Measurements on a White Screen Using Replica Masks ” 1998‐SID International Symposium Digest of Technical Papers Society for Information Display Vol. 29 Anaheim CA (May 17‐22 1998) pp.941–944.10.1889/1.1833919 ↗
13. See11.2.2 Sampling‐Sphere Implementation Information Display Measurements Standard(IDMS) version 1.03 International Committee for Display Metrology (ICDM) Society for Information Display (SID) (June2012). Wall measurements to determine the illuminance are featured.
14. See for example 11.3 Hemispherical Reflection Specular Excluded and the appendix B17 Reflection Models & Terminology Information Display Measurements Standard(IDMS) version 1.03 International Committee for Display Metrology (ICDM) Society for Information Display (SID) (June2012).
15. T.G.FiskeandL.D.Silverstein “Estimating Display Modulation by 2‐D Fourier Transform: A Preferred Method ” 2005‐SID International Symposium Digest of Technical Papers Society for Information Display paper 37.1 pp.1326–1329.10.1889/1.2036249 ↗
16. 10.1113/jphysiol.1968.sp00857410.1113/jphysiol.1968.sp008574 ↗
17. 11.9 Ambient Contrast Information Display Measurements Standard(IDMS) version 1.03 International Committee for Display Metrology (ICDM) Society for Information Display (SID) (June2012).
18. As an example seeE.Talvalaet al. “Veiling glare in high dynamic range imaging ” Assoc. for Computing Machinery (ACM) Transactions on Graphics Proceedings of ACM SIGGRAPH 2007 Vol. 26 No. 3 article 37 (July2007).10.1145/1276377.1276424 ↗