journal article·2010-05

Eyepiece focus and vergence/accommodation conflict: Implications for night‐vision devices

Marie Charbonneau, Alain Léger, Bernard Claverie

Publisher page

Abstract

Abstract— Aviation increasingly conducts night operations using night‐vision devices. However, design of some aspects may limit performance. As pointed out by Kotulak, vergence/accommodation mismatch in NVDs, usually due to eyepiece focus misadjustments, is sometimes a source of visual acuity (VA) decrement. The increased separation between sensors, existing in some binocular helmetmounted displays, was also identified to be potentially responsible for decreased VA at short distances. Based upon knowledge pertaining to vergence and accommodation, a study was performed to better understand the problem of dissociation accommodation/convergence. Different conditions of interocular separation and viewing distances were used. Twelve subjects participated and were asked to resolve Landolt C charts using night‐vision goggles. The results show that, with the eyepiece focus fixed at 10 m, the decrease in VA is roughly proportional to the interocular separation, when looking at short distances. A fixed eyepiece focus at 4 m considerably reduces the conflict and results in improved VA. An additional experiment was conducted to investigate the effect of fixing the objective lenses focus at infinity. With this setting, the decrease in VA at a short distance was such that effects of the mismatch accommodation/convergence are no longer apparent regardless of the interocular separation.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Visual perception and processing mechanisms · Impact of Light on Environment and Health · Ophthalmology and Visual Impairment Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. 1998 · 373
2. 10.1046/j.1475-1313.1996.95001131.x10.1046/j.1475-1313.1996.95001131.x ↗
3. Brettel H. · 1993 · 115
4. Bartlett N.R. · 1965 · 185
5. 10.1038/1871121c010.1038/1871121c0 ↗
6. Ciuffreda K J · 1991 · 231
7. G J NClarkson “The integration of helmet‐mounted devices with aircrew equipment ”SAFE (Europe) J. 12–22(1993).
8. 10.1068/p19017110.1068/p190171 ↗
9. 10.3758/BF0320818910.3758/BF03208189 ↗
10. G AGleasonandJ TRiegler “The effect of eyepiece focus on visual acuity through ANVIS night vision goggles during short‐and long‐term wear ”Wright‐Patterson AFB Air Force Research Laboratory Report No. AFRL/HE‐WP‐TR‐2001‐0033 (2001).10.21236/ADA388987 ↗
11. 10.1068/p14061710.1068/p140617 ↗
12. A.Karavis “Trends in helmet‐mounted equipment ”Neck Injury in Advanced Military Aircraft Environments NATO AGARD AGARD‐CP‐471 (1989).
13. A.KaravisandD NJarrett “The quest for an integrated flying helmet ”Combat automation for airborne weapon systems: man/machine interface trends and technologies NATO AGARD. AGARD‐CP‐520 (1992).
14. “Focus adjustment effects on visual acuity and oculomotor balance with aviator night vision displays
15. “Optical compensation for night myopia based on dark focus and CA/C ratio
16. J CKotulakandC ERash “Visual acuity with second and third generation night‐vision goggles obtained from a new method of night sky simulation across a wide range of target contrast ”U.S. Army Aeromedical Research Laboratory USSARL Report No. 92‐9 (1992).10.21236/ADA248786 ↗
17. J PMenuet al. “Etude du concept de visualisation intermédiaire (Study of head level display concept) ”Centre d'Etudes et de Recherche de Médecine Aérospatiale Rapport CERMA Report No. 84.30 (French)(1984).
18. “Optically induced changes in the couplings between vergence and accommodation
19. North Atlantic Treaty Organization's (NATO's) Research and Technology Organization (RTO) Panel on Human Factors and Medicine HFM‐091/RTG‐027 Common Methodological Basis for Evaluation and Testing of Visionic Devices Report AC/323(HFM‐091)TP/76(2008).
20. Priot A E · 2006
21. A EPriotet al. "Adaptation to increased interocular distance: survey of Tiger pilots training. Human Factors and Medical Aspects of Day/Night All Weather Operations: Current Issues and Future Challenges "RTO Human Factors and Medicine Panel (HFM) Symposium 23-25 (2007)
22. Heraklion Greece RTO‐MP‐HFM‐141 (2007).
23. “Optical defocus: differential effects on size and contrast letter recognition thresholds
24. J CRabin “Image contrast and visual acuity through Night Vision Goggles ”U.S. Army Aeromedical Research Laboratory USSARL Report No. 96‐26 (1996).
25. “Depth and distance scaling under telestereoscopic viewing: the roles of vergence and differential perspective,”
26. 10.1016/0042-6989(79)90208-610.1016/0042-6989(79)90208-6 ↗
27. 10.1016/0042-6989(86)90151-310.1016/0042-6989(86)90151-3 ↗
28. Semmlow J L · 1981 · 161
29. Task H L · 2000
30. Helmholtz H L F · 1867
31. 10.2307/141978210.2307/1419782 ↗
32. 10.2307/141915610.2307/1419156 ↗