Accuracy of colour production on a CRT display as a function of the measurement instrument used for calibration
Source abstract
Abstract
Abstract— This investigation determined the error associated with colour reproduction when different light meters were used to characterize a CRT. Luminance measurements were taken with three light‐measuring instruments to produce gamma tables. The tables were used to calibrate 28 colours. Results showed that the most acceptable instrument was one that accurately measured light below 0.001 cd/m2 and that used colour‐matching tables to weight the radiant energy. Less‐sensitive instruments that used fixed filters to model the colour‐matching functions produced colours that were perceptibly different from the specified colours. The reproduction errors were evaluated against colour discrimination thresholds and ΔE*. If accurate reproduction of luminance is not essential, a less‐sensitive instrument with a cutoff of 0.01 cd/m2 and three separate filters for modeling the colour‐matching functions may be adequate. Complete gamma‐correction tables (voltage input/luminance output) for each gun were not necessary. Accurate colour calibration can be based on a limited number of luminance measurements plus an interpolation procedure to determine the intervening values in the gamma tables. The reliability of the initial characterization was tested after an interval of 9 months. The maximum luminance of the monitor decreased considerably over this time period. A simple recalibration method, outlined by Lucassen and Walraven (Ref. 1) was effective in restoring luminance accuracy. This method allows for periodic adjustments to the luminance output on a CRT using a small number of measurements.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Color Science and Applications · Surface Roughness and Optical Measurements · Industrial Vision Systems and Defect Detection
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (7)
Show source-provided references
1. 10.1002/col.508015060610.1002/col.5080150606 ↗
2. W. B.Cowan CIE Calibration of Video Monitors Technical Report National Research Council of Canada Division of Physics Ottawa Canada (1983).
3. D. L.PostandC. S.Calhoun “An evaluation of methods for producing specific colors on CRTs ”inProc Human Factors Society 31st Annual Meeting 1276–1280(1987).10.1177/154193128703101122 ↗
4. J.WalravenandJ.Alferdinck Colour Specifications for the Electronic Chart Display and Information System (ECDIS) Report IZF 1990 A‐19 TNO Institute for Perception Soesterberg The Netherlands (1990).
5. Wyszecki G. · 1982
6. 10.1364/JOSA.32.00024710.1364/JOSA.32.000247 ↗
7. Widdel H. · 199210.1007/978-1-4757-9754-1 ↗