journal article·2001-09

LCoS microdisplay throughput measurements

David J. W. Aastuen, Charles L. Bruzzone

Publisher page

Abstract

Abstract— We propose a straightforward method to measure the absolute throughput of an LCoS microdisplay. The method requires two measurements. The first measurement is of the lumens delivered from a testbed, which includes the microdisplay under test, with a folded light path. The second measurement is of the lumens delivered by the unfolded testbed with the microdisplay removed. This second measurement is used to normalize the first to obtain a fractional transmission that a designer can use to make a meaningful prediction of the system brightness of a LCoS‐based projection system.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Semiconductor Lasers and Optical Devices · Photonic and Optical Devices · Advanced optical system design

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (8)

Show source-provided references
1. E. H.StuppandM. S.Brennesholtz Projection Displays(Wiley‐SID Series in Display Technology 239ff. 1999).
2. 10.1147/rd.423.038710.1147/rd.423.0387 ↗
3. 10.1147/rd.423.033910.1147/rd.423.0339 ↗
4. 10.1147/rd.423.040110.1147/rd.423.0401 ↗
5. “Liquid Crystals for LCoS,”
6. 10.1117/12.34936110.1117/12.349361 ↗
7. B.VerweireandR.Defever “Limitation of resolution of LCoS‐based projection displays by diffraction effects ”Proc 19th Intl Display Research Conf (EuroDisplay '99) 489–492(1999).
8. 10.1117/12.34934710.1117/12.349347 ↗