Mathematical modelling and experimental validation of thermal conductivity of outer layer of fire protective clothing
Source abstract
Abstract
Motivation for development of this mathematical model is the difficulties related to the experimental measurement of the thermal conductivity like frequent sample preparation, experimental setup availability and lack of easier methods for quick estimation of thermal conductivity of outer layer of fire protective clothing. Considering this, various studies were devoted in the past to determine the thermal conductivity of fabrics. Two mathematical approaches for prediction of thermal conductivity of woven outer layer have been presented in the present study. Series-parallel thermal resistance configuration has been used for prediction of effective thermal conductivity of the fabric. First approach uses input values of structural parameters and can be useful in the development of new woven fabrics for outer layer of fire protective clothing. Second approach uses fibre volume fraction and thermal conductivity of fibre and air. It is suitable for predicting thermal conductivity of finished fabrics. The values obtained from mathematical model were validated with experimental values.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Textile materials and evaluations · Thermoregulation and physiological responses · Natural Fiber Reinforced Composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Textile and Fiber Engineering, Indian Institute of Technology Delhi, New Delhi, India
Department of Mechanical Engineering, Indian Institute of Technology Bhilai, Durg, India
References (21)
Show source-provided references
1. Bhattacharjee, D., & Kothari, V. K. (2005). A theoretical model to predict the thermal resistance of plain woven fabrics. Indian Journal of Fibre and Textile Research, 30, 252–257.
2. 10.1016/0307-904X(88)90075-310.1016/0307-904X(88)90075-3 ↗
3. 10.1080/1944702580866011910.1080/19447025808660119 ↗
4. 10.1080/0040500070158256210.1080/00405000701582562 ↗
5. 10.1080/00405000.2012.74078910.1080/00405000.2012.740789 ↗
6. 10.1080/00405000.2023.225048610.1080/00405000.2023.2250486 ↗
7. 10.1533/978184569442510.1533/9781845694425 ↗
8. National Fire Protection Association (1971).
9. 10.1080/1944702370865880910.1080/19447023708658809 ↗
10. 10.1080/00405000.2022.215671710.1080/00405000.2022.2156717 ↗
11. 10.1177/1528083722111761010.1177/15280837221117610 ↗
12. 10.1177/1528083721105458210.1177/15280837211054582 ↗
13. 10.1177/1528083721105458210.1177/15280837211054582 ↗
14. 10.1177/1528083722114921710.1177/15280837221149217 ↗
15. 10.1080/00405000.2022.214544110.1080/00405000.2022.2145441 ↗
16. Rengasamy, R. S., & Kawabata, S. (2002). Computation of thermal conductivity of fibre from thermal conductivity of twisted yarn. Indian Journal of Fibre and Textile Research, 27(4), 342–345.
17. 10.1016/j.commatsci.2013.04.00310.1016/j.commatsci.2013.04.003 ↗
18. 10.2115/fiber.66.p_5610.2115/fiber.66.p_56 ↗
19. 10.1201/978042944487610.1201/9780429444876 ↗
20. 10.1080/00405000.2023.220191310.1080/00405000.2023.2201913 ↗
21. Torvi D. A. (1997). Heat transfer in thin fibrous materials under high heat flux conditions [Unpublished doctoral dissertation].