Outgassing behavior of different high-temperature resistant polymers
Source abstract
Abstract
In vacuum applications, polymers often need to be used in spite of their relatively high outgassing rates, e.g., as sealing or spacer material. For some polymers—like Viton®, which is used for O-rings—data on outgassing rates can be found in literature, while for others, in particular, the most relevant ones that can be used at higher temperatures, only few results are available. Therefore, different high-temperature resistant polymers were measured at the Outgassing Measurement Apparatus, which uses the difference method. These polymers were polyimides like Kapton®, Vespel®, and Meldin®, as well as a polyetheretherketone and a polybenzimidazole. In order to investigate the temperature behavior of the outgassing of the polymers, the measurements were performed at room temperature, 100 °C, and 200 °C. The outgassing species were determined by a mass spectrometer. In addition, the dependence of the outgassing on the material thickness was analyzed. The paper shows that the outgassing rates of the examined polymers are higher than 10−4 (Pa m3)/(s m2) after 10 h at room temperature, except for the thin Kapton samples. Thus, further treatment of the materials will be necessary depending on the application. It is shown that a vacuum bake-out at not less than 200 °C is favorable. The main outgassing species is water, as expected, but also different hydrocarbons with higher mass can be seen for the polyimides. Concerning different thicknesses, the outgassing rate of a thin sample generally decreases more steeply than the outgassing rate of the thicker sample. Nevertheless, the steepest decrease was found for the thickest Kapton sample, with a difference of nearly factor 500 between 10 and 100 h at room temperature.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Scientific Measurement and Uncertainty Evaluation · Electrostatic Discharge in Electronics · Engineering and Material Science Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Karlsruhe Institute of Technology (KIT), Institute for Technical Physics , Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
Funding
Helmholtz-Gemeinschaft
References (17)
Show source-provided references
1. Vacuum · 1967 · 17 · 54710.1016/0042-207X(67)90002-4 ↗
2. Vacuum · 2002 · 65 · 13710.1016/S0042-207X(01)00420-1 ↗
3. IEEE Trans. Dielectr. Electr. Insul. · 2004 · 11 · 61310.1109/TDEI.2004.1324351 ↗
4. Rev. Sci. Instrum. · 2016 · 87 · 02B30910.1063/1.4932615 ↗
5. D. Coyne, “Polyimide hydrocarbon outgas rate and temperature limits for the isolation system actuator,” https://dcc-llo.ligo.org/public/0027/T040032/000/T040032-01.pdf, LIGO-T040032-01-D.
6. Meas. Sci. Technol. · 2013 · 24 · 03700110.1088/0957-0233/24/3/037001 ↗
7. High Perform. Polym. · 1990 · 2 · 2510.1177/152483999000200103 ↗
8. J. Vac. Sci. Technol. · 1980 · 17 · 33010.1116/1.570380 ↗
9. J. Vac. Sci. Technol. · 1973 · 10 · 54310.1116/1.1318061 ↗
10. Vacuum · 1977 · 27 · 60510.1016/S0042-207X(77)80442-9 ↗
11. C. E. Powers, “Outgassing data for selecting spacecraft materials,” NASA, http://outgassing.nasa.gov/
12. J. Vac. Sci. Technol., A · 2015 · 33 · 02160310.1116/1.4905099 ↗
13. Vacuum · 2015 · 122 · 25010.1016/j.vacuum.2015.03.033 ↗
14. Fusion Eng. Des. · 2015 · 100 · 43110.1016/j.fusengdes.2015.07.011 ↗
15. 2016
16. 2009
17. 2016