Recommended procedure for measuring pumping speeds
Source abstract
Abstract
The American Vacuum Society’s tentative standard for measuring pumping speed was first issued in 1963 and published in a revised form in 1971. The newly established Recommended Practices Committee of AVS felt that it was appropriate to review the standard to reconcile it with modern developments in technology and technique. These include among others: new units for pressure measurement, establishment of new pumping methods, recognition of emergence of international standards, and general improvements in high-vacuum practices. The main substantial change involves the positioning of the pressure gauge in the measurement chamber at a distance from the pump entrance equivalent to 0.5 of pump inlet diameter. This will reduce the measured speed values by 10% to 15%, depending on pump size and inlet geometry, but will correspond more closely to the definition of pumping speed in relation to the time of evacuation of a given volume.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Intravenous Infusion Technology and Safety · Flow Measurement and Analysis · Scientific Measurement and Uncertainty Evaluation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Varian/Vacuum Products Division, Lexington, Massachusetts 02173