journal article·2006-07-01

Understanding ion-milling damage in Hg1−xCdxTe epilayers

Changzhen Wang, David J. Smith, Steve Tobin, Themis Parodos, Jun Zhao, Yong Chang, Sivalingam Sivananthan

Publisher page

Abstract

Transmission electron microscopy (TEM) is widely used for the characterization of the microstructure of Hg1−xCdxTe epilayers. Traditional TEM sample preparation methods, which usually involve argon ion milling, can easily cause damage to the material, and the size and density of the induced defects depend on the milling conditions. In this work, the structural damage caused by argon ion milling of Hg1−xCdxTe epilayers has been investigated. Multilayer samples with different Hg concentrations, as grown by molecular beam epitaxy, and p-n heterojunctions, as grown by liquid-phase epitaxy, have been examined. It is shown that, in addition to the milling conditions, the extent of the ion-induced damage depends sensitively on the Hg concentration of the Hg1−xCdxTe alloy as well as the epilayer growth conditions (i.e., Hg rich or Te rich). A possible mechanism that explains these results is briefly discussed.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Semiconductor Detectors and Materials · Electronic and Structural Properties of Oxides · Nuclear Materials and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Arizona State University Center for Solid State Science, , Tempe, Arizona 85287 and Department of Physics and Astronomy, , Tempe, Arizona 85287

BAE Systems , Lexington, Massachusetts 02421

University of Illinois Microphysics Laboratory, Department of Physics, , Chicago, Illinois 60607

References (32)

Show source-provided references
1. Opto-Electron. Rev. · 2002 · 10 · 159
2. Rep. Prog. Phys. · 2005 · 68 · 226710.1088/0034-4885/68/10/R01 ↗
3. 1994
4. Proc. SPIE · 2004 · 5564 · 6510.1117/12.566470 ↗
5. Opto-Electron. Rev. · 2003 · 11 · 211
6. Semicond. Sci. Technol. · 1991 · 6 · C610.1088/0268-1242/6/12C/002 ↗
7. J. Electron. Mater. · 2004 · 33 · 50910.1007/s11664-004-0039-4 ↗
8. J. Electron. Mater. · 2004 · 33 · 66710.1007/s11664-004-0065-2 ↗
9. J. Vac. Sci. Technol. A · 1985 · 3 · 12810.1116/1.573183 ↗
10. J. Cryst. Growth · 2004 · 265 · 22410.1016/j.jcrysgro.2004.01.063 ↗
11. Micron · 1999 · 30 · 26710.1016/S0968-4328(99)00011-6 ↗
12. Ultramicroscopy · 1993 · 52 · 10110.1016/0304-3991(93)90025-S ↗
13. Ultramicroscopy · 1985 · 17 · 20310.1016/0304-3991(85)90087-7 ↗
14. Ultramicroscopy · 1987 · 23 · 17510.1016/0304-3991(87)90163-X ↗
15. Appl. Phys. Lett. · 2003 · 83 · 478510.1063/1.1633017 ↗
16. Appl. Phys. Lett. · 2005 · 86 · 13192410.1063/1.1890471 ↗
17. J. Electron. Mater. · 2006 · 35 · 119210.1007/s11664-006-0240-8 ↗
18. J. Cryst. Growth · 1985 · 73 · 37910.1016/0022-0248(85)90316-1 ↗
19. J. Vac. Sci. Technol. B · 1992 · 10 · 146010.1116/1.586272 ↗
20. J. Cryst. Growth · 1988 · 86 · 70010.1016/0022-0248(90)90798-P ↗
21. J. Cryst. Growth · 1988 · 86 · 72310.1016/0022-0248(90)90799-Q ↗
22. Proc. SPIE · 1984 · 510 · 121
23. J. Electron. Mater. · 2003 · 32 · 81010.1007/s11664-003-0075-5 ↗
24. J. Appl. Phys. · 1998 · 83 · 129910.1063/1.366829 ↗
25. Ultramicroscopy · 2001 · 87 · 12310.1016/S0304-3991(00)00095-4 ↗
26. Ultramicroscopy · 1987 · 21 · 32710.1016/0304-3991(87)90031-3 ↗
27. Radiat. Eff. Defects Solids · 1991 · 116 · 8110.1080/10420159108221347 ↗
28. Kuo · 1992 · 556
29. 199
30. Nucl. Instrum. Methods Phys. Res. B · 2001 · 175–177 · 274
31. J. Appl. Phys. · 2002 · 92 · 574510.1063/1.1512695 ↗
32. Semicond. Phys., Quantum Electron. Optoelectron. · 2003 · 6 · 4710.15407/spqeo6.01.047 ↗