Analysis of Langmuir probe data: Analytical parametrization, and the importance of the end effect
Source abstract
Abstract
The ion current to a cylindrical or spherical Langmuir probe can be represented as Ii=I0a(−X)b, where I0 is the ion flux to the edge of the probe sheath, X is the dimensionless probe potential, and a and b are parameters depending on the ratio of the probe radius rp to the Debye length λD and the probe geometry. We present analytical expressions for a and b which are valid over a wide range of rp/λD. We also discuss under which conditions the end of a cylindrical probe contributes appreciably to the probe current. Neglecting the end effect may lead to a significant overestimate of the ion density.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Plasma Diagnostics and Applications · Magnetic Field Sensors Techniques · Non-Destructive Testing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Materials Science and Engineering Department, Rensselaer Polytechnic Institute, Troy, New York 12180
References (8)
Show source-provided references
1. J. Vac. Sci. Technol. A · 1999 · 17 · 84010.1116/1.581656 ↗
2. Jpn. J. Appl. Phys., Part 1 · 2000 · 39 · 135110.1143/JJAP.39.1351 ↗
3. J. Vac. Sci. Technol. B · 2000 · 18 · 81110.1116/1.591281 ↗
4. J. Appl. Phys. · 2000 · 87 · 164210.1063/1.372072 ↗
5. Plasma Sources Sci. Technol. · 2000 · 8 · 534
6. J. Vac. Sci. Technol. A · 1990 · 8 · 166310.1116/1.576782 ↗
7. J. Vac. Sci. Technol. A · 1999 · 17 · 305110.1116/1.582004 ↗
8. J. Vac. Sci. Technol. A · 1998 · 16 · 219810.1116/1.581512 ↗