journal article·2014-03-01

Development of atomic layer deposition-activated microchannel plates for single particle detection at cryogenic temperatures

Dmitry Gorelikov, Neal Sullivan, Philippe de Rouffignac, Huazhi Li, Jayasri Narayanamoorthy, Anton S. Tremsin

Publisher page

Abstract

Atomic layer deposition (ALD) technology is used to nanoengineer functional films inside the pores of microchannel plate (MCP) electron multipliers, enabling a novel MCP manufacturing technology that substantially improves performance and opens novel applications. The authors have developed custom tools and recipes for the growth of conformal films, with optimized conductance and secondary electron emission inside very long channels (∼6–20 μm diameter and >600 μm length, with tens of millions of channels per single MCP) by ALD. The unique ability to tune the characteristics of these ALD films enables their optimization to applications where time-resolved single particle imaging can be performed in extreme conditions, such as high counting rates at cryogenic temperatures. Adhesion of the conductive and emissive nanofilms to the 20 μm pore MCP glass substrates and their mechanical stability over a very wide range of temperatures (10–700 K) were confirmed experimentally. Resistance of ALD MCPs was reproducible during multiple cool-down cycles with no film degradation observed. Optimizing resistance of novel MCPs for operation at cryogenic temperature should enable high count rate event detection at temperatures below 20 K.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Photocathodes and Microchannel Plates · Electron and X-Ray Spectroscopy Techniques · Dark Matter and Cosmic Phenomena

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Arradiance Inc. , 142 North Road, Sudbury, Massachusetts 01776

Funding

DOE

References (24)

Show source-provided references
1. Nucl. Instrum. Meth. A · 2009 · 607 · 8110.1016/j.nima.2009.03.134 ↗
2. 2009
3. Nucl. Instrum. Meth. A · 2011 · 633 · S5910.1016/j.nima.2010.06.121 ↗
4. Nucl. Instrum. Meth. A · 2011 · 659 · 39410.1016/j.nima.2011.08.019 ↗
5. Nucl. Instrum. Meth. A · 2011 · 639 · 16510.1016/j.nima.2010.10.068 ↗
6. Nucl. Instrum. Meth. A · 2012 · 695 · 16810.1016/j.nima.2011.11.022 ↗
7. IEEE Trans. Nucl. Sci. · 2013 · 60 · 92310.1109/TNS.2013.2252364 ↗
8. Nucl. Instrum. Meth. A · 2013 · 718 · 53510.1016/j.nima.2012.11.109 ↗
9. 2012
10. Nucl. Instrum. Meth. A · 2009 · 610 · 11810.1016/j.nima.2009.05.116 ↗
11. IEEE Trans. Nucl. Sci. · 2007 · 54 · 70610.1109/TNS.2007.894816 ↗
12. Nucl. Instrum. Meth. A · 2011 · 629 · 12310.1016/j.nima.2010.10.087 ↗
13. Nucl. Instrum. Meth. A · 2000 · 439 · 13410.1016/S0168-9002(99)00792-5 ↗
14. Proc. SPIE · 1996 · 2808 · 8610.1117/12.256043 ↗
15. 2008 · 1179
16. Phys. Rev. Lett. · 2009 · 103 · 21300210.1103/PhysRevLett.103.213002 ↗
17. Nucl. Instrum. Meth. A · 2010 · 621 · 8310.1016/j.nima.2010.06.008 ↗
18. Rev. Sci. Instrum. · 2011 · 82 · 06511210.1063/1.3602928 ↗
19. Nucl. Instrum. Meth. A · 1992 · 320 · 55610.1016/0168-9002(92)90950-9 ↗
20. Science · 1999 · 284 · 196710.1126/science.284.5422.1967 ↗
21. Rev. Sci. Instrum. · 2007 · 78 · 11330110.1063/1.2814030 ↗
22. Proc. SPIE · 1989 · 1072 · 11110.1117/12.952545 ↗
23. Rev. Sci. Instrum. · 2004 · 75 · 106810.1063/1.1666981 ↗
24. J. Am. Ceram. Soc. · 1951 · 34 · 1410.1111/j.1151-2916.1951.tb13009.x ↗