Measurements of tritium retention and removal on the Tokamak Fusion Test Reactor
Source abstract
Abstract
Recent experiments on the Tokamak Fusion Test Reactor have afforded an opportunity to measure the retention of tritium in a graphite limiter that is subject to erosion, codeposition, and high neutron flux. The tritium was injected by both gas puff and neutral beams. The isotopic mix of hydrogenic recycling was measured spectroscopically and the tritium fraction T/(H+D+T) transiently increased to as high as 75%. Some tritium was pumped out during the experimental run and some removed in a subsequent campaign using various clean-up techniques. While the short term retention of tritium was high, various conditioning techniques were successful in removing ≊8000 Ci and restoring the tritium inventory to a level well below the administrative limit.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fusion materials and technologies · Magnetic confinement fusion research · Muon and positron interactions and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08543
References
Reference metadata was not supplied for this record.