Growth and trends in Auger-electron spectroscopy and x-ray photoelectron spectroscopy for surface analysis
Source abstract
Abstract
A perspective is given of the development and use of surface analysis, primarily by Auger-electron spectroscopy (AES) and x-ray photoelectron spectroscopy (XPS), for solving scientific and technological problems. Information is presented on growth and trends in instrumental capabilities, instrumental measurements with reduced uncertainties, knowledge of surface sensitivity, and knowledge and effects of sample morphology. Available analytical resources are described for AES, XPS, and secondary-ion mass spectrometry. Finally, the role of the American Vacuum Society in stimulating improved surface analyses is discussed.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electron and X-Ray Spectroscopy Techniques · X-ray Spectroscopy and Fluorescence Analysis · Ion-surface interactions and analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Surface and Microanalysis Science Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899-8370
References (75)
Show source-provided references
1. Accuracy of the Non-Destructive Surface Nanostructure Quantification Technique Based on Analysis of the XPS or AES Peak Shape
2. Practical Surface Analysis: State of the Art and Recent Developments in AES, XPS, ISS and SIMS10.1002/sia.740090104 ↗
3. NIST Data Resources for Surface Analysis by X-ray Photoelectron Spectroscopy and Auger Electron Spectroscopy
4. J. Appl. Phys. · 1968 · 39 · 242510.1063/1.1656571 ↗
5. Report on the 22nd IUVSTA Workshop X-Ray Photoelectron Spectroscopy: From Physics to Data10.1002/1096-9918(200010)29:10<671::AID-SIA910>3.0.CO;2-5 ↗
6. Photoelectron Microscopy and Applications in Surface and Materials Science10.1016/S0079-6816(02)00007-2 ↗
7. Precision, Accuracy, and Uncertainty in Quantitative Surface Analyses by Auger-Electron Spectroscopy and X-ray Photoelectron Spectroscopy10.1116/1.576956 ↗
8. The Alignment of Spectrometers and Quantitative Measurements in X-ray Photoelectron Spectroscopy10.1016/S0368-2048(97)00084-4 ↗
9. Signal Linearity in XPS Counting Systems10.1016/S0368-2048(98)00317-X ↗
10. Standard Test Data for Estimating Peak Parameter Errors in X-ray Photoelectron Spectroscopy: II. Peak Intensities10.1002/1096-9918(200007)29:7<444::AID-SIA888>3.0.CO;2-M ↗
11. Validation and Accuracy of Software for Peak Synthesis in XPS10.1016/S0368-2048(98)00204-7 ↗
12. Surface Characterization of Catalysts Using Electron Spectroscopies—Results of a Round-Robin Sponsored by ASTM Committee D-32 on Catalysts10.1016/0368-2048(77)85033-0 ↗
13. Results of a Joint Auger/ESCA Round Robin Sponsored by ASTM Committee E-42 on Surface Analysis. Part I. ESCA Results10.1016/0368-2048(79)80001-8 ↗
14. Results of a Joint Auger/ESCA Round Robin Sponsored by ASTM Committee E-42 on Surface Analysis. Part II. Auger Results10.1016/0368-2048(82)85010-X ↗
15. Summary Abstract: Accurate Determination of the Energies of Auger Electrons and Photoelectrons from Nickel, Copper, and Gold10.1116/1.571409 ↗
16. Energy Calibration of X-ray Photoelectron Spectrometers: Results of an Interlaboratory Comparison to Evaluate a Proposed Calibration Procedure10.1002/sia.740230302 ↗
17. Energy Calibration of X-ray Photoelectron Spectrometers. II. Issues in Peak Location and Comparison of Methods10.1002/(SICI)1096-9918(199709)25:10<777::AID-SIA299>3.0.CO;2-3 ↗
18. Energy Calibration of X-ray Photoelectron Spectrometers III. Location of the Zero Point on the Binding-Energy Scale10.1002/(SICI)1096-9918(199807)26:8<606::AID-SIA405>3.0.CO;2-8 ↗
19. Elemental Binding Energies for X-ray Photoelectron Spectroscopy10.1016/0169-4332(95)00027-5 ↗
20. XPS: Binding Energy Calibration of Electron Spectrometers 4—Assessment of Effects for Different X-ray Sources, Analyser Resolutions, Angles of Emission and of the Overall Uncertainties10.1002/(SICI)1096-9918(199808)26:9<617::AID-SIA407>3.0.CO;2-V ↗
21. XPS Binding Energy Calibration of Electron Spectrometers 5—Re-evaluation of the Reference Energies10.1002/(SICI)1096-9918(199808)26:9<642::AID-SIA408>3.0.CO;2-3 ↗
22. AES: Energy Calibration of Electron Spectrometers III General Calibration Rules10.1016/S0368-2048(96)03097-6 ↗
23. AES: Energy Calibration of Electron Spectrometers. IV. A Re-evaluation of the Reference Energies10.1016/S0368-2048(98)00299-0 ↗
24. Summary of ISO/TC 201 Standard VH ISO 15472: 2001—Surface Chemical Analysis—X-ray Photoelectron Spectrometers—Calibration of Energy Scales10.1002/sia.1076 ↗
25. Summary of the American Society for Testing and Materials Practice E 2108-00 for Calibration of the Electron Binding-Energy Scale of an X-ray Photoelectron Spectrometer10.1116/1.1384560 ↗
26. Summary of ISO/TC 201 Standard XI, ISO 17974: 2002–Surface chemical analysis–High-resolution Auger electron spectrometers–Calibration of energy scales for elemental and chemical-state analysis10.1002/sia.1529 ↗
27. Summary of ISO/TC 201 Standard XII. ISO 17973: 2002–Surface chemical analysis–Medium-resolution Auger electron spectrometers–Calibration of energy scales for elemental analysis10.1002/sia.1530 ↗
28. AES—Accurate Intensity Calibration of Electron Spectrometers—Results of a BCR Interlaboratory Comparison Cosponsored by the VAMAS SCA TWP10.1002/sia.740171206 ↗
29. XPS Reference Procedure for the Accurate Intensity Calibration of Electron Spectrometers—Results of a BCR Intercomparison Cosponsored by the VAMAS SCA TWA10.1002/sia.740200309 ↗
30. A System for the Intensity Calibration of Electron Spectrometers10.1016/0368-2048(94)02275-5 ↗
31. Quantitative AES. VIII. Analysis of Auger Electron Intensities from Elemental Data in a Digital Auger Database10.1002/(SICI)1096-9918(199811)26:12<908::AID-SIA438>3.0.CO;2-H ↗
32. Quantitative XPS. I. Analysis of X-ray Photoelectron Intensities from Elemental Data in a Digital Photoelectron Database
33. Quantitative AES IX and Quantitative XPS II: Auger and X-ray Photoelectron Intensities and Sensitivity Factors from Spectral Digital Databases Reanalysed Using a REELS Database10.1002/sia.1109 ↗
34. Quantitative AES. VI. Backscattering and Backgrounds—An Analysis of Elemental Systematics and Corrections of Absolute Intensity10.1002/(SICI)1096-9918(199809)26:10<723::AID-SIA418>3.0.CO;2-L ↗
35. Quantitative AES. VII. The Ionization Cross Section in AES10.1002/(SICI)1096-9918(199810)26:11<815::AID-SIA427>3.0.CO;2-1 ↗
36. Quantitative AES and XPS Convergence Between Theory and Experimental Databases10.1016/S0368-2048(99)00040-7 ↗
37. Generalized Model for Interface Descriptions10.1016/S0039-6028(98)00094-6 ↗
38. Simple Method of Depth Profiling (Stratifying) Contamination Layers, Illustrated by Studies on Stainless Steel10.1002/sia.740210603 ↗
39. Angle-Resolved XPS Depth-Profiling Strategies10.1016/S0169-4332(98)00752-1 ↗
40. Surface Nanostructure Determination by X-ray Photoelectron Spectroscopy Peak Shape Analysis10.1116/1.579963 ↗
41. Partial Intensity Analysis (PIA) for Quantitative Electron Spectroscopy10.1002/sia.740231103 ↗
42. Elimination of the Inelastic Tail and Suppression of the Background of Secondaries and Backscattered Primaries in AES/XPS Spectra10.1002/(SICI)1096-9918(19980515)26:6<455::AID-SIA389>3.0.CO;2-W ↗
43. Comparison of Source Functions Obtained by Using QUASES and Partial Intensity Analysis for Inelastic Backgound Correction: KLL Auger Spectra of 3d Transition Elements Cu and Ni10.1002/sia.1442 ↗
44. Comparison of Validity and Consistency of Methods for Quantitative XPS Peak Analysis10.1002/sia.740201302 ↗
45. Approach for Determining Area Selectivity in Small Area XPS Analysis10.1002/1096-9918(200011)29:11<766::AID-SIA927>3.0.CO;2-Y ↗
46. Artifacts in AES Microanalysis for Semiconductor Applications10.1002/1096-9918(200008)30:1<377::AID-SIA829>3.0.CO;2-M ↗
47. Minimum Detectable Dimension, Resolving Power, and Quantification of Scanning Auger Microscopy at High Spatial Resoltion10.1002/sia.740140612 ↗
48. Three-Dimensional Scatter Diagrams: Application to Surface Analytical Microscopy10.1016/0304-3991(94)90015-9 ↗
49. Data Processing for Spectrum-Images: Extracting Information from the Data Mountain10.1016/S0169-4332(98)00754-5 ↗
50. From LEED to MULSAM10.1002/1096-9918(200009)29:9<561::AID-SIA899>3.0.CO;2-E ↗
51. Multivariate Image Analysis Methods Applied to XPS Imaging Data Sets,”10.1002/sia.1201 ↗
52. Edge Effects and Image Contrast in Scanning Auger Microscopy: A Theory/Experiment Comparison10.1002/sia.740110506 ↗
53. Monte Carlo Simulations of Edge Artefacts in MULSAM Images
54. Comparison of Submicron Particle Analysis by Auger Electron Spectroscopy, Time of Flight Secondary Ion Mass Spectrometry, and Secondary Electron Microscopy with Energy Dispersive X-Ray Spectroscopy10.1116/1.580027 ↗
55. Comparison of the Submicron Particle Analysis Capabilities of Auger Electron Spectroscopy, Time-of Flight Secondary Ion Mass Spectrometry, and Scanning Electron Microscopy with Energy-Dispersive X-Ray Spectroscopy for Particles Deposited on Silicon Wafers with 1 μm Thick Oxide Layers10.1116/1.581417 ↗
56. J. Vac. Sci. Technol. A · 1998 · 16 · 314810.1116/1.581477 ↗
57. Quantitation of Coverages on Rough Surfaces by XPS: An Overview10.1002/sia.740130404 ↗
58. Channeling Effects in Polycrystalline Copper—A Serious Impediment to Quantitative Auger Analysis?10.1002/sia.740060607 ↗
59. Crystalline Effects on Auger Emission: The Influence of the Electron Channelling of the Probe in Scanning Auger Microscopy10.1016/0039-6028(85)90703-4 ↗
60. Measurements of the Magnitude of Crystalline Effects in Auger Electron Spectroscopy10.1002/sia.740150106 ↗
61. The Influence of Diffraction Effects on Quantitative Auger Electron Spectroscopy10.1002/sia.740160124 ↗
62. The Effects of Photoelectron Diffraction on Quantitative X-ray Photoelectron Spectroscopy10.1002/sia.740170406 ↗
63. Modulated Electron Emission by Scattering-Interference of Primary Electrons10.1142/S0218625X9700016X ↗
64. Ultrathin SiO2 on Si. II. Issues in Quantification of the Oxide Thickness10.1002/sia.1433 ↗
65. X-Ray Photoelectron and Auger Electron Forward Scattering: A New Tool for Surface Crystallography10.1080/10408439008244629 ↗
66. Epitaxial Film Crystallography by High Energy Auger and X-Ray Photoelectron Diffraction10.1080/00018739100101502 ↗
67. Elastic Scattering and Interference of Backscattered Primary, Auger, and X-Ray Photoelectrons at High Kinetic Energy: Principles and Applications10.1016/0167-5729(92)90016-5 ↗
68. X-Ray Photoelectron and Auger-Electron Forward Scattering: A New Tool for Studying Epitaxial Growth and Core-Level Binding-Energy Shifts10.1103/PhysRevB.30.1052 ↗
69. The Electron Attenuation Length Revisited10.1016/S0167-5729(02)00031-6 ↗
70. The Application of Electron Spectroscopy to Surface Studies10.1116/1.1318572 ↗
71. The Probing Depth in Photoemission and Auger-Electron Spectroscopy10.1016/0368-2048(74)80024-1 ↗
72. Attenuation Lengths of Low-Energy Electrons in Solids10.1016/0039-6028(74)90091-0 ↗
73. The Quest for Universal Curves to Describe the Surface Sensitivity of Electron Spectroscopies10.1016/0368-2048(88)85012-6 ↗
74. Evaluation of Calculated and Measured Electron Inelastic Mean Free Paths Near Solid Surfaces10.1063/1.556035 ↗
75. Quantitative Electron Spectroscopy of Surfaces: A Standard Database for Electron Inelastic Mean Free Paths in Solids10.1002/sia.740010103 ↗