Precision parts cleaning using supercritical fluids
Source abstract
Abstract
Supercritical fluid extraction and chromatography measurements were made on pieces of disk drive actuator components in order to understand how to clean and analyse these parts. Extract analyses were made by Fourier transform infrared (FTIR) and flame ionization detector measurements. Hydrocarbons, silicones, and fluorocarbons were seen on various pieces of different samples using FTIR, time-of-flight static secondary-ion mass spectrometry (TOF-SSIMS), and x-ray photoelectron spectroscopy. In addition TOF-SSIMS detected di-isooctyl phthalate. Silicones and di-isooctyl phthalate could be removed by CO2 extraction.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Ion-surface interactions and analysis · Analytical chemistry methods development · Phase Equilibria and Thermodynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Manufacturing Research, IBM, Yorktown Heights, New York 10598
Physical Sciences, IBM, Yorktown Heights, New York 10598
References