journal article·2011-09-01

Investigations of a method for determining pumping speed and sorption capacity of nonevaporable getters based on in situ calibrated throughput

Bojan Erjavec, Janez Setina

Publisher page

Abstract

This paper presents a gas-sorption method, based on an in situ calibrated throughput, for characterizing nonevaporable getters (NEGs) of Ti- and Zr-based alloys. The main characteristics of the method are the adjustment of a constant injected gas flow, the prompt calibration of a throughput, and the measurement of an increasing sorption pressure. It is essential that inert vacuum gauges be selected for measurements of total pressure to prevent contamination of a test gas and poisoning of an NEG under test. A capacitance diaphragm gauge is used for preparation of the injected gas flow by filling the gas reservoir with a test gas and adjusting the conductance of a variable leak valve. A spinning rotor gauge (SRG) is used for in situ calibration of the throughput by means of an integrated gas-flow calibration facility and the rate-of-pressure-rise method, and by continuous measurement of the sorption pressure in a test chamber. A getter pumping speed and a sorbed quantity are calculated while considering the throughput, the sorption pressure, and the sorption time. The throughput must be selected in accordance with both the sorption characteristics of a particular NEG type and the measurement capabilities of the SRG. At room temperature, porous thick-film NEGs and structured thin-film NEGs exhibit an initial getter pumping speed on the order of 1 and 0.1 l s−1 cm−2, respectively. The corresponding sorption capacity of a few times 10−4 mbar l cm−2 is comparable for all chemically active gases except for H2, which amounts to a few times 100 × 10−3 mbar l cm−2 in the case of porous NEGs and ∼1 × 10−3 mbar l cm−2 in the case of structured NEGs. Detailed analysis of uncertainties of SRG pressure measurements below 1 × 10−3 mbar gives an expanded uncertainty of the getter pumping speed and the sorbed quantity of 1.9% and 3.5%, respectively. While temporally interrupting the throughput, the setup enables discrete measurements of the background pressure, which increases because of the accumulation of nongetterable gases. After completion of the gas-sorption test, a qualitative determination of the accumulated inert gas composition is performed by the gas-burst method using a quadrupole mass spectrometer (QMS) mounted on a vacuum system. The quantitative analysis is enabled by the use of a QMS calibrated in situ by known amounts of a certain gas such as H2, CH4, CO, Ar and Kr.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Semiconductor materials and devices · 3D IC and TSV technologies · Advancements in Photolithography Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute of Metals and Technology 1 , Lepi pot 11, 1000 Ljubljana, Slovenia

References (27)

Show source-provided references
1. Vacuum · 2001 · 64 · 1510.1016/S0042-207X(01)00366-9 ↗
2. Proc. SPIE · 1999 · 3889 · 7510.1117/12.359356 ↗
3. Proc. SPIE · 2004 · 5343 · 7010.1117/12.530414 ↗
4. J. Vac. Sci. Technol. A · 2009 · 27 · 32110.1116/1.3081969 ↗
5. J: Vac. Sci. Technol. A · 1987 · 5 · 22010.1116/1.574107 ↗
6. ASTM Standard F 798-97 · 1997
7. 2005–2007
8. Vacuum · 1990 · 41 · 210910.1016/0042-207X(90)94192-S ↗
9. 2011
10. J. Vac. Sci. Technol. A · 1987 · 5 · 255210.1116/1.574420 ↗
11. J. Vac. Sci. Technol. A · 1985 · 3 · 171510.1116/1.573007 ↗
12. J. Vac. Sci. Technol. A · 1991 · 9 · 273710.1116/1.577191 ↗
13. Vacuum · 1990 · 41 · 211510.1016/0042-207X(90)94194-U ↗
14. Mater. Tehnol. · 2007 · 41 · 145
15. J. Vac. Sci. Technol. · 1980 · 17 · 64210.1116/1.570531 ↗
16. J. Vac. Sci. Technol. A · 1989 · 7 · 335610.1116/1.576150 ↗
17. Vacuum · 1982 · 32 · 68510.1016/0042-207X(82)94048-9 ↗
18. Rev. Sci. Instrum. · 1994 · 65 · 301210.1063/1.1144594 ↗
19. Vacuum · 1988 · 38 · 83910.1016/0042-207X(88)90475-7 ↗
20. J. Vac. Sci. Technol. A · 1986 · 4 · 172410.1116/1.573965 ↗
21. Vacuum · 2006 · 81 · 23410.1016/j.vacuum.2006.03.011 ↗
22. Vacuum · 1990 · 40 · 5110.1016/0042-207X(90)90117-H ↗
23. Vacuum · 2003 · 71 · 34110.1016/S0042-207X(02)00759-5 ↗
24. Vacuum · 1992 · 44 · 57710.1016/0042-207X(93)90099-V ↗
25. J. Vac. Sci. Technol. A · 1999 · 17 · 208610.1116/1.581913 ↗
26. J. Vac. Sci. Technol. A · 1993 · 11 · A2210.1116/1.4755937 ↗
27. Proc. SPIE · 2008 · 6884 · 210