Extremely low-outgassing material: 0.2% beryllium copper alloy
Source abstract
Abstract
Exploration for low-outgassing materials for use in ultrahigh vacuum and extreme high-vacuum systems is one of the most important topics of a vacuum researcher. We have found that a copper alloy containing 0.2% beryllium (0.2% BeCu) can attain an extremely low hydrogen outgassing rate of 10−14 Pa (H2) m/s order. Almost the entire surface of 0.2% BeCu is dominated by a BeO layer, after a 400 °C×72 h prebakeout treatment in an ultrahigh vacuum. This layer functions as a barrier to the processes of oxidization and permeation of hydrogen. In addition, this layer resists carbon contamination. Temperature-programmed desorption spectra show only a single peak for water at 150 °C and small quantities of any other desorption gases. Therefore, an in situ bakeout process in which the temperature simply ramps up to 150 °C and immediately ramps back down is enough for degassing; it does not require an ordinary sustained-temperature bakeout. Using an outgassing sample consisting of 0.2% BeCu disks housed in a 0.2% BeCu nipple chamber, a lowest outgassing rate of the 5.6×10−14 Pa (H2) m/s was measured by the pressure-rise method after pump cutoff. The pressure-rise versus time curve was completely nonlinear. It rises over time to a constant slope of 1/2 in a log–log plot, due to hydrogen diffusion from the bulk, but this requires over a week at room temperature. The hydrogen outgassing from the 0.2% BeCu bulk is completely dominated by a diffusion-limited mechanism. This article will describe why we obtain such low-outgassing rates with 0.2% BeCu. It is based on the observed surface changes with prebakeout treatment seen by x-ray photoelectron spectroscopy, and the improvement of hydrogen outgassing measurements by the pressure-rise method. A comparison is made to ordinary stainless steel. In addition, the concept of an outgassing reduction method will be discussed from a review of the published ultralow-outgassing data and reduction methods.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Scientific Measurement and Uncertainty Evaluation · Advanced Sensor Technologies Research · Nuclear Physics and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Vaclab Incorporated, SOHO Building, 2-10-2 Matsushiro-Tsukuba, Ibaraki 305-0035, Japan
References (25)
Show source-provided references
1. J. Vac. Sci. Technol. A · 1993 · 11 · 162010.1116/1.578468 ↗
2. J. Vac. Sci. Technol. A · 1995 · 13 · 49710.1116/1.579387 ↗
3. J. Vac. Sci. Technol. A · 1995 · 13 · 258710.1116/1.579455 ↗
4. Vacuum · 1996 · 47 · 70910.1016/0042-207X(96)00053-X ↗
5. J. Vac. Soc. Jan. · 1994 · 37 · 67810.3131/jvsj.37.678 ↗
6. J. Vac. Sci. Technol. A · 2001 · 19 · 64010.1116/1.1339009 ↗
7. J. Vac. Sci. Technol. A · 1993 · 11 · 162010.1116/1.578468 ↗
8. Vacuum · 1999 · 52 · 33310.1016/S0042-207X(98)00314-5 ↗
9. J. Vac. Sci. Technol. A · 1999 · 17 · 346710.1116/1.582084 ↗
10. J. Vac. Sci. Technol. A · 2002 · 20 · 122210.1116/1.1479736 ↗
11. J. Vac. Sci. Technol. A · 1996 · 14 · 259910.1116/1.579987 ↗
12. Vacuum · 1996 · 47 · 32510.1016/0042-207X(95)00245-6 ↗
13. J. Vac. Sci. Technol. A · 1999 · 17 · 104010.1116/1.581680 ↗
14. J. Vac. Sci. Technol. A · 2001 · 19 · 22810.1116/1.1333083 ↗
15. J. Vac. Sci. Technol. A · 2002 · 20 · 84810.1116/1.1471354 ↗
16. J. Vac. Sci. Technol. A · 1995 · 13 · 14710.1116/1.579430 ↗
17. J. Vac. Sci. Technol. A · 2001 · 19 · 21510.1116/1.1322653 ↗
18. Vacuum · 1998 · 49 · 35910.1016/S0042-207X(98)00002-5 ↗
19. Vacuum · 1999 · 53 A 19 · 197
20. Vacuum · 1998 · 49 · 30910.1016/S0042-207X(98)00001-3 ↗
21. J. Vac. Sci. Technol. A · 1995 · 13 · 14010.1116/1.579428 ↗
22. J. Vac. Soc. Jan. · 1984 · 27 · 45710.3131/jvsj.27.457 ↗
23. J. Vac. Sci. Technol. A · 1987 · 5 · 3710.1116/1.574134 ↗
24. Vacuum · 1996 · 47 · 68910.1016/0042-207X(96)00048-6 ↗
25. J. Vac. Sci. Technol. A · 1995 · 13 · 14010.1116/1.579428 ↗