journal article·1992-09-01

Langmuir probe and optical emission studies of Ar, O2, and N2 plasmas produced by an electron cyclotron resonance microwave source

A. A. Shatas, Y. Z. Hu, E. A. Irene

Publisher page

Abstract

An understanding of electron cyclotron resonance microwave plasma discharges requires the measurement of plasma parameters. In argon, nitrogen and oxygen plasmas, cylindrical Langmuir probes were used to determine the variations of plasma parameters (ion density Ni, floating potential Vf, plasma potential Vp, and electron temperature Te) with applied power (100–300 W) and pressures (1–10×10−4 Torr). Simultaneous optical emission (OE) spectra were also obtained, and, using knowledge of excited and neutral peak intensities and transition energies, the electron temperatures were calculated. By the use of the Langmuir probe electron temperature results, the electron temperatures obtained from OE resulted in scaling factors C of 2, 0.15, and 2 eV−0.75 for argon, oxygen, and nitrogen, respectively.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Plasma Diagnostics and Applications · Plasma Applications and Diagnostics · Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599-3290

References